On the performances of a hybrid air-conditioning system in different climatic conditions

被引:70
作者
Bergero, Stefano [1 ]
Chiari, Anna [1 ]
机构
[1] Univ Genoa, DSA, Fac Architecture, I-16123 Genoa, Italy
关键词
Hybrid air-conditioning systems; Air dehumidification; Liquid desiccant; Membrane contactor; Energy saving; LIQUID-DESICCANT DEHUMIDIFICATION; MEMBRANE CONTACTOR; VAPOR-COMPRESSION;
D O I
10.1016/j.energy.2011.06.030
中图分类号
O414.1 [热力学];
学科分类号
摘要
In previous papers the authors demonstrated that significant energy savings can be achieved in air-conditioning through the use of a hybrid plant in which a vapor-compression inverse cycle is integrated with an air dehumidification system working with hygroscopic solution and hydrophobic membrane. The advantage of this system lies in the fact that the refrigeration device operates at a higher evaporation temperature than that of a traditional system, in which dehumidification is achieved through condensation. In the proposed hybrid system the supplied air is simultaneously cooled and dehumidified in an air-solution membrane contactor. The LiCl solution is cooled by means of a vapor-compression inverse cycle. The solution is regenerated in another membrane contactor by exploiting the exhaust air and the heat rejected by the condenser. The paper reports a study of the steady-state behavior of the system in summer climatic conditions on varying some significant climatic parameters, such as the latent load of the conditioned space and the outdoor and indoor relative humidity. The performances of the hybrid system are compared with those of a traditional direct-expansion air-conditioning plant. Results of the simulations reveal that energy saving may exceed 60% when the latent load in the conditioned environment is high. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:5261 / 5273
页数:13
相关论文
共 32 条
[1]   Recent advances in building air conditioning systems [J].
Afonso, Clito F. A. .
APPLIED THERMAL ENGINEERING, 2006, 26 (16) :1961-1971
[2]  
Ahmed CSK, 1997, APPL THERM ENG, V17, P125
[3]   The effect of absorber packing height on the performance of a hybrid liquid desiccant system [J].
Ani, FN ;
Badawi, EM ;
Kannan, KS .
RENEWABLE ENERGY, 2005, 30 (15) :2247-2256
[4]  
ANSI/ASHRAE, 2007, 6212007 ANSIASHRAE
[5]   Experimental and theoretical analysis of air humidification/dehumidification processes using hydrophobic capillary contactors [J].
Bergero, S ;
Chiari, A .
APPLIED THERMAL ENGINEERING, 2001, 21 (11) :1119-1135
[6]  
Bergero S., 2006, P ESDA2006 8 BIENN A, P1
[7]  
Bergero S., 2001, P 7 RHEVA WORLD C CL
[8]   Performance analysis of a liquid desiccant and membrane contactor hybrid air-conditioning system [J].
Bergero, Stefano ;
Chiari, Anna .
ENERGY AND BUILDINGS, 2010, 42 (11) :1976-1986
[9]  
CHIARI A, 2000, INT J AMBIENT ENERGY, V20, P187
[10]  
CHUNG TW, 1993, P 1993 WINT M ASHRAE