Application of a Receptor-Binding Capture Quantitative Reverse Transcription-PCR Assay To Concentrate Human Norovirus from Sewage and To Study the Distribution and Stability of the Virus
被引:31
作者:
Tian, Peng
[1
]
Yang, David
[1
]
Pan, Liangwen
[2
]
Mandrell, Robert
[1
]
机构:
[1] ARS, Produce Safety & Microbiol Res Unit, Western Reg Res Ctr, USDA, Albany, CA 94710 USA
[2] Shanghai Entry Exit Inspect & Quarantine Bur, Shanghai, Peoples R China
关键词:
NORWALK-LIKE VIRUSES;
WASTE-WATER TREATMENT;
ENTERIC VIRUSES;
GENETIC DIVERSITY;
GENOGROUP-I;
TREATMENT-PLANT;
GASTROENTERITIS;
OUTBREAKS;
STRAINS;
SAMPLES;
D O I:
10.1128/AEM.06875-11
中图分类号:
Q81 [生物工程学(生物技术)];
Q93 [微生物学];
学科分类号:
071005 [微生物学];
090105 [作物生产系统与生态工程];
摘要:
Water is an important route for human norovirus (HuNoV) transmission. Using magnetic beads conjugated with blood group-like antigens (HuNoV receptors), we developed a simple and rapid receptor-binding capture and magnetic sequestration (RBCMS) method and compared it to the existing negatively charged membrane absorption/elution (NCMAE) method for concentrating HuNoV from sewage effluent. RBCMS required 6-fold-less sample volume than the NCMAE method and also resulted in a significantly higher yield of HuNoV. The NCMAE and RBCMS concentrations of genogroup I (GI) HuNoV measured by quantitative reverse transcription-PCR (qRT-PCR) resulted in average threshold cycle (C-T) values of 34.68 (8.68 copies, 252-fold concentration) versus 34.07 (13.05 copies, 477-fold concentration), respectively; the NCMAE and RBCMS concentrations of genogroup II (GII) HuNoV were measured as average C-T values of 33.32 (24.7 copies, 239-fold concentration) versus 32.38 (46.9 copies, 333-fold concentration), respectively. The specificity of qRT-PCR was confirmed by traditional RT-PCR and an RNase I protection assay. The qRT-PCR signal from RBCMS-concentrated HuNoV treated with RNase I indicated that it was from encapsidated RNA and, probably, viable virus. In contrast, the qRT-PCR signal from NCMAE-concentrated HuNoV was not protected from RNase I and, likely, degradation. Both GI and GII HuNoV were detected from sewage effluent samples collected between April and July with average concentrations of 7.8 x 10(3) genomic copies per liter (gc/liter) and 4.3 x 10(4) gc/liter, respectively. No GI and <2% GII HuNoV were detected in sewage samples stored at room temperature for 4 weeks. We conclude that RBCMS requires less sample volume, has better recovery and sensitivity, and is faster than NCMAE for detection of HuNoV in sewage.
引用
收藏
页码:429 / 436
页数:8
相关论文