SAUNA - a system for automatic sampling, processing, and analysis of radioactive xenon

被引:244
作者
Ringbom, A [1 ]
Larson, T
Axelsson, A
Elmgren, K
Johansson, C
机构
[1] Swedish Def Res Agcy, Div Syst Technol, FOI, SE-17290 Stockholm, Sweden
[2] Univ Uppsala, Angstrom Lab, Dept Neutron Res, S-75120 Uppsala, Sweden
关键词
radioxenon; CTBT verification; charcoal adsorption; beta-gamma coincidence techniques;
D O I
10.1016/S0168-9002(03)01657-7
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A system for automatic sampling, processing, and analysis of atmospheric radioxenon has been developed. From an air sample of about 7 m(3) collected during 12 h, 0.5 cm(3) of xenon is extracted, and the atmospheric activities from the four xenon isotopes (133) Xe, (135)xe, Xe-131m, and Xe-133m are determined with a beta-gamma coincidence technique. The collection is performed using activated charcoal and molecular sieves at ambient temperature. The sample preparation and quantification are performed using preparative gas chromatography. The system was tested under routine conditions for a 5-month period, with average minimum detectable concentrations below 1 mBq/m(3) for all four isotopes. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:542 / 553
页数:12
相关论文
共 16 条
[1]  
AUER M, 2000, 3 INT M LOW LEV AIR
[2]  
AUER M, IN PRESS
[3]  
AXELSSON A, IN PRESS
[4]  
Bernstrom B., 1983, C20515A1 FOA
[5]   Trace gas emissions on geological faults as indicators of underground nuclear testing [J].
Carrigan, CR ;
Heinle, RA ;
Hudson, GB ;
Nitao, JJ ;
Zucca, JJ .
NATURE, 1996, 382 (6591) :528-531
[7]  
DEGEER LE, MONITORING COMPREHEN, P157
[8]  
JOHANSSON C, IN PRESS
[9]   XENON-133 - AMBIENT ACTIVITY FROM NUCLEAR-POWER STATIONS [J].
KUNZ, CO ;
PAPERIELLO, CJ .
SCIENCE, 1976, 192 (4245) :1235-1237
[10]  
PERKINS RW, 1996, DOERL9651