Effect of magnetic field treated water on mortar and concrete containing fly ash

被引:124
作者
Su, N [1 ]
Wu, CF [1 ]
机构
[1] Natl Yunlin Univ Sci & Technol, Dept Construct Engn, Huwei 640, Taiwan
关键词
magnetic field treated water; fly ash; compressive strength; workability; mortar;
D O I
10.1016/S0958-9465(02)00098-7
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This research investigates the workability and compressive strength of mortar and concrete, which were mixed with magnetic field treated water (MFTW) and contained fly ash. MFTW was obtained by passing tap water through a magnetic field. Test variables included the magnetic strength of water, fly ash content in place of cement, water-to-cementitious material ratio (W/CM) and curing age. Results show that the compressive strength of mortar samples mixed with MFTW is higher than those prepared with tap water. The best compressive strength increase of concrete is achieved when the magnetic strength of treated water is of 0.8 and 1.2 T. The compressive strength increase of concrete prepared with MFTW is more significant at early age. (C) 2002 Elsevier Ltd. All rights reserved.
引用
收藏
页码:681 / 688
页数:8
相关论文
共 13 条
[1]  
[Anonymous], PRACTICAL TECHNOLOGY
[2]  
[Anonymous], NEW CONSTRUCTION MET
[3]  
[Anonymous], FLY ASH CONCRETE
[4]  
Fu W., 1994, NEW TECHNOLOGY CONCR, P56
[5]  
Helmuth R.A., 1987, Fly Ash in Cement and Concrete
[6]  
Horne RA, 1962, MAR CHEM, P568
[7]  
LI KT, 1994, WORLD MAGNETISM, P107
[8]  
Mehta P.K., 1986, Concrete. Structure, Properties, and Materials, V2nd
[9]  
SNOEYINK L, 1982, WATER CHEM, P2
[10]   Effect of magnetic water on the engineering properties of concrete containing granulated blast-furnace slag [J].
Su, N ;
Wu, YH ;
Mar, CY .
CEMENT AND CONCRETE RESEARCH, 2000, 30 (04) :599-605