Effects of quantum noise and binocular summation on dose requirements in stereoradiography

被引:18
作者
Maidment, ADA [1 ]
Bakic, PR [1 ]
Albert, M [1 ]
机构
[1] Hosp Univ Penn, Dept Radiol, Philadelphia, PA 19104 USA
关键词
digital radiography; stereoradiographic technique; dose; observer study; human perception;
D O I
10.1118/1.1621869
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In the case of a quantum-noise limited detector, signal detection theory suggests that stereoradiographic images can be acquired with one half of the per-image dose needed for a standard radiographic projection, as information from the two stereo images can be combined. Previously, filmscreen stereoradiography has been performed using the same per-image dose as in projection radiography, i.e., doubling the total dose. In this paper, the assumption of a possible decrease in dose for stereoradiography was tested by a series of contrast-detail experiments, using phantom images acquired over a range of exposures. The number of visible details, the effective reduction of the dose, and the effective decrease in the threshold signal-to-noise ratio were determined using human observers under several display and viewing conditions. These results were averaged over five observers and compared with multiple readings by a single observer and with the results of an additional observer with limited stereoscopic acuity. Experimental results show that the total dose needed to produce a stereoradiographic image pair is approximately 1.1 times the dose needed for a single projection in standard radiography, indicating that under these conditions the human visual system demonstrates almost ideal binocular summation. (C) 2003 American Association of Physicists in Medicine.
引用
收藏
页码:3061 / 3071
页数:11
相关论文
共 27 条
[1]   Defect interpolation in digital radiography - how object-oriented transform coding helps [J].
Aach, T ;
Metzler, V .
MEDICAL IMAGING: 2001: IMAGE PROCESSING, PTS 1-3, 2001, 4322 :824-835
[2]  
[Anonymous], BINOCULAR VISION
[3]   2-AFC observer study of digital stereomammography [J].
Bakic, PR ;
Albert, M ;
Maidment, ADA .
MEDICAL IMAGING 2003: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2003, 5034 :1-9
[4]   Mammogram synthesis using a 3D simulation. II. Evaluation of synthetic mammogram texture [J].
Bakic, PR ;
Albert, M ;
Brzakovic, D ;
Maidment, ADA .
MEDICAL PHYSICS, 2002, 29 (09) :2140-2151
[5]   Dose requirements in stereoradiography [J].
Bakic, PR ;
Albert, M ;
Maidment, ADA .
MEDICAL IMAGING 2002: PHYSICS OF MEDICAL IMAGING, 2002, 4682 :126-137
[6]  
BARTEN PGJ, 1992, SPIE P, V1666, P57
[7]  
BERKSON J, 1960, AM REV RESPIR DIS, V81, P660
[8]   Statistical texture synthesis of mammographic images with clustered lumpy backgrounds [J].
Bochud, FO ;
Abbey, CK ;
Eckstein, MP .
OPTICS EXPRESS, 1999, 4 (01) :33-43
[9]   A NOISE MASKING EXPERIMENT IN GRATING PERCEPTION AT THRESHOLD - THE IMPLICATIONS ON BINOCULAR SUMMATION [J].
BRACCINI, C ;
GAMBARDELLA, G ;
SUETTA, G .
VISION RESEARCH, 1980, 20 (04) :373-376
[10]   MONOCULAR VERSUS BINOCULAR VISUAL ACUITY [J].
CAMPBELL, FW ;
GREEN, DG .
NATURE, 1965, 208 (5006) :191-&