Capillary electrophoresis for the determination of glomerular filtration rate using nonradioactive iohexol

被引:32
作者
Rocco, MV
Buckalew, VM
Moore, LC
Shihabi, ZK
机构
[1] WAKE FOREST UNIV,BOWMAN GRAY SCH MED,BAPTIST HOSP,DEPT CLIN CHEM,WINSTON SALEM,NC 27157
[2] WAKE FOREST UNIV,BOWMAN GRAY SCH MED,DEPT INTERNAL MED NEPHROL,WINSTON SALEM,NC 27157
关键词
glomerular filtration rate; measurement; chronic renal insufficiency; iohexol; iothalamate; capillary electrophoresis; high-performance liquid chromatography;
D O I
10.1016/S0272-6386(96)90298-X
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
High-performance liquid chromatography (HPLC) has been used as an alternative to the isotopic method to calculate glomerular filtration rate (GFR), With the HPLC method, serum iohexol or iothalamate levels are measured, and the plasma clearance rate of the compound is used as a surrogate for GFR. However, HPLC is a labor-intensive procedure, which limits its usefulness in the clinical setting, Capillary electrophoresis, a newer technique in which electrophoretic separations are performed in capillary tubes, is easier and faster than HPLC. We used capillary electrophoresis for the determination of serum iohexol levels and the calculation of GFR, Patients underwent a simultaneous I-125-iothalamate clearance test and a plasma iohexol clearance test to determine GFR, Mean GFR (+/- SD) was 70.9 +/- 29.9 mL/min (range, 14.5 to 131 mL/min) in 52 patients as determined by standard iothalamate clearance methods. For iohexol clearance, the correlation coefficient and standard error were 0.93 and 10.9 mL/min, respectively, using capillary electrophoresis compared with the iothalamate method, Capillary electrophoresis is a simple, rapid method that can be used to calculate GFR and provides results at least as accurate as those obtained by HPLC and x-ray fluorescence. (C) 1996 by the National Kidney Foundation, Inc.
引用
收藏
页码:173 / 177
页数:5
相关论文
共 16 条
[1]   IOHEXOL CLEARANCE FOR THE DETERMINATION OF GLOMERULAR-FILTRATION RATE IN CLINICAL-PRACTICE - EVIDENCE FOR A NEW GOLD STANDARD [J].
BROWN, SCW ;
OREILLY, PH .
JOURNAL OF UROLOGY, 1991, 146 (03) :675-679
[2]  
BUBECK B, 1992, EUR J NUCL MED, V19, P511
[3]   GLOMERULAR-FILTRATION RATE - A COMPARISON BETWEEN CR-EDTA CLEARANCE AND A SINGLE SAMPLE TECHNIQUE WITH A NONIONIC CONTRAST AGENT [J].
ERIKSSON, CG ;
KALLNER, A .
CLINICAL BIOCHEMISTRY, 1991, 24 (03) :261-264
[4]  
GASPARI F, 1995, J AM SOC NEPHROL, V6, P257
[5]   MEASUREMENT OF GFR WITH A SINGLE INTRAVENOUS-INJECTION OF NONRADIOACTIVE IOTHALAMATE [J].
GASPARI, F ;
MOSCONI, L ;
VIGANO, G ;
PERICO, N ;
TORRE, L ;
VIROTTA, G ;
BERTOCCHI, C ;
REMUZZI, G ;
RUGGENENTI, P .
KIDNEY INTERNATIONAL, 1992, 41 (04) :1081-1084
[6]   CAPILLARY ELECTROPHORESIS [J].
GORDON, MJ ;
HUANG, XH ;
PENTONEY, SL ;
ZARE, RN .
SCIENCE, 1988, 242 (4876) :224-228
[7]   MODIFIED PLASMA-CLEARANCE TECHNIQUE USING NONRADIOACTIVE IOTHALAMATE FOR MEASURING GFR [J].
ISAKA, Y ;
FUJIWARA, Y ;
YAMAMOTO, S ;
OCHI, S ;
SHIN, SH ;
INOUE, T ;
TAGAWA, K ;
KAMADA, T ;
UEDA, N .
KIDNEY INTERNATIONAL, 1992, 42 (04) :1006-1011
[8]  
LEVEY AS, 1993, J AM SOC NEPHROL, V4, P1159
[9]   MEASUREMENT OF THE PLASMA-CLEARANCE OF UROGRAPHIC CONTRAST-MEDIA FOR THE DETERMINATION OF GLOMERULAR-FILTRATION RATE [J].
OREILLY, PH ;
JONES, DA ;
FARAH, NB .
JOURNAL OF UROLOGY, 1988, 139 (01) :9-11
[10]   UTILITY OF RADIOISOTOPIC FILTRATION MARKERS IN CHRONIC RENAL-INSUFFICIENCY - SIMULTANEOUS COMPARISON OF I-125 IOTHALAMATE, YB-169 DTPA, TC-99M-DTPA, AND INULIN [J].
PERRONE, RD ;
STEINMAN, TI ;
BECK, GJ ;
SKIBINSKI, CI ;
ROYAL, HD ;
LAWLOR, M ;
HUNSICKER, LG .
AMERICAN JOURNAL OF KIDNEY DISEASES, 1990, 16 (03) :224-235