A novel transducer for the measurement of cement-prosthesis interface forces in cemented orthopaedic devices

被引:6
作者
Cristofolini, L [1 ]
Marchetti, A
Cappello, A
Viceconti, M
机构
[1] Ist Ortoped Rizzoli, Lab Tecnol Med, Bologna, Italy
[2] Univ Bologna, Fac Ingn, DIEM, Bologna, Italy
[3] Univ Bologna, Fac Ingn, DEIS, Bologna, Italy
关键词
biomechanics; orthopaedics; cemented prosthesis; force measurement; interface force; piezoelectricity; load cells;
D O I
10.1016/S1350-4533(00)00068-0
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
When a cemented orthopaedic device is being investigated there is a need to estimate the forces at the cement-prosthesis interface. For this reason a miniature transducer was developed that could be included inside the surface of most prostheses. A load cell (based on a piezoelectric sensor) and the required accessories and amplification were custom designed and built. The present work describes the validation that was performed on the piezo sensors alone, when mounted on a simplified structure, and when applied to a hip stem. Linearity, repeatability, reproducibility, and sensibility to shear and axial eccentric loads were tested, yielding satisfactory results. The repeatability on the same sensor was found to be good while reproducibility between sensors was lower. Thus: each sensor was calibrated separately with a second order relationship. Sensitivity to shear and eccentric loads was very low. The overall accuracy of the load cell (including non-linearity, and signal drift) was of the order of about 1%. A hip stem instrumented with four such sensors was successfully implanted in a composite femur, yielding meaningful readouts. Thus, this type of sensor can readily be used to assess the cement-prosthesis interface forces in cemented devices. (C) 2001 IPEM. Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:493 / 501
页数:9
相关论文
共 24 条
[1]
AHNFELT L, 1990, ACTA ORTHOP SCAND, V61, P1
[2]
BURKE DW, 1984, T 30 ORTH RES SOC AT, P296
[3]
A critical analysis of stress shielding evaluation of hip prostheses [J].
Cristofolini, L .
CRITICAL REVIEWS IN BIOMEDICAL ENGINEERING, 1997, 25 (4-5) :409-483
[4]
Mechanical validation of whole bone composite femur models [J].
Cristofolini, L ;
Viceconti, M ;
Cappello, A ;
Toni, A .
JOURNAL OF BIOMECHANICS, 1996, 29 (04) :525-535
[5]
Towards the standardization of in vitro load transfer investigations of hip prostheses [J].
Cristofolini, L ;
Viceconti, M .
JOURNAL OF STRAIN ANALYSIS FOR ENGINEERING DESIGN, 1999, 34 (01) :1-15
[6]
Development and validation of a technique for strain measurement inside polymethyl methacrylate [J].
Cristofolini, L ;
Viceconti, M .
JOURNAL OF STRAIN ANALYSIS FOR ENGINEERING DESIGN, 2000, 35 (01) :21-33
[7]
DOEBELIN EO, 1990, MEASUREMENT SYSTEMS
[8]
A TECHNIQUE FOR EMBEDDING STRAIN-GAUGES WITHIN CURING BONE-CEMENT [J].
DRAGANICH, LF ;
ANDRIACCHI, TP ;
GALANTE, JO .
JOURNAL OF BIOMECHANICS, 1982, 15 (10) :789-790
[9]
ENGH CA, 1988, CLIN ORTHOP RELAT R, P7
[10]
Factors affecting cement strains near the tip of a cemented femoral component [J].
Estok, DM ;
Orr, TE ;
Harris, WH .
JOURNAL OF ARTHROPLASTY, 1997, 12 (01) :40-48