Determination of cadmium, mercury and lead in soil samples by slurry sampling electrothermal vaporization inductively coupled plasma mass spectrometry

被引:30
作者
Chen, SF [1 ]
Jiang, SJ [1 ]
机构
[1] Natl Sun Yat Sen Univ, Dept Chem, Kaohsiung 80424, Taiwan
关键词
D O I
10.1039/a802873g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Ultrasonic slurry sampling electrothermal vaporization isotope dilution inductively coupled plasma mass spectrometry (USS-ETV-ID-ICP-MS) was applied to the determination of Cd, Hg and Pb in several soil samples. Palladium was used as the modifier. Since the sensitivities of the elements studied in soil slurry and aqueous solution were different, the isotope dilution method was used for the determination of Cd, Hg and Ph in selected soil samples. The influences of instrument operating conditions, slurry preparation and interferences on the ion signals and the accuracy and precision of isotope ratio determinations were reported. The isotope ratios of each element were calculated from the peak areas of each injection peak. The precision of the isotope ratio determinations was better than 4%. This method was applied to the determination of Cd, Hg and Pb in NIST SRM 2711 Montana soil reference material and several soil samples collected from the Kaohsiung area. The results for the reference sample NIST SRM 2711 Montana Soil agreed satisfactorily with the certified values. Results for other samples analysed by the isotope dilution method and the method of standard additions agreed satisfactorily. The precision was better than 5% and the accuracy was better than 2% with the USS-ETV-ID-ICP-MS method. Detection limits estimated from standard addition curves were in the ranges 4-24, 2-19 and 5-76 ng g(-1) for Cd, Hg and Pb, respectively, in different samples.
引用
收藏
页码:1113 / 1117
页数:5
相关论文
共 19 条
[1]   SOLID SAMPLING IN ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY USING COMMERCIAL ATOMIZERS - A REVIEW [J].
BENDICHO, C ;
DELOOSVOLLEBREGT, MTC .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1991, 6 (05) :353-374
[2]   Determination of copper, cadmium and lead in biological samples by electrothermal vaporization isotope dilution inductively coupled plasma mass spectrometry [J].
Chang, CC ;
Jiang, SJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (01) :75-80
[3]   SELECTION OF MODE FOR THE MEASUREMENT OF LEAD ISOTOPE RATIOS BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY AND ITS APPLICATION TO MILK POWDER ANALYSIS [J].
DEAN, JR ;
EBDON, L ;
MASSEY, R .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1987, 2 (04) :369-374
[4]   THE ROLE OF CHEMICAL MODIFIERS IN ANALYTE TRANSPORT LOSS INTERFERENCES WITH ELECTROTHERMAL VAPORIZATION ICP-MASS SPECTROMETRY [J].
EDIGER, RD ;
BERES, SA .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1992, 47 (07) :907-922
[5]   ANALYTE TRANSPORT STUDIES OF AQUEOUS-SOLUTIONS AND SLURRY SAMPLES USING ELECTROTHERMAL VAPORIZATION ICP-MS [J].
FONSECA, RW ;
MILLERIHLI, NJ .
APPLIED SPECTROSCOPY, 1995, 49 (10) :1403-1410
[6]   ELECTROTHERMAL VAPORIZATION FOR INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY AND ATOMIC-ABSORPTION SPECTROMETRY - SYMBIOTIC ANALYTICAL TECHNIQUES [J].
GREGOIRE, DC ;
LAMOUREUX, M ;
CHAKRABARTI, CL ;
ALMAAWALI, S ;
BYRNE, JP .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (04) :579-585
[7]   DIRECT ANALYSIS OF SOLIDS BY ULTRASONIC SLURRY ELECTROTHERMAL VAPORIZATION INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY [J].
GREGOIRE, DC ;
MILLERIHLI, NJ ;
STURGEON, RE .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (05) :605-610
[8]   VAPRIZATION OF ACIDS AND THEIR EFFECT ON ANALYTE SIGNAL IN ELECTROTHERMAL VAPORIZATION INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY [J].
GREGOIRE, DC ;
GOLTZ, DM ;
LAMOUREUX, MM ;
CHAKRABARTI, CL .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (09) :919-926
[9]   USE OF MG/PD CHEMICAL MODIFIERS FOR THE DETERMINATION OF VOLATILE ELEMENTS BY ELECTROTHERMAL VAPORIZATION ICP-MS - EFFECT ON MASS-TRANSPORT EFFICIENCY [J].
GREGOIRE, DC ;
ALMAAWALI, S ;
CHAKRABARTI, CL .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1992, 47 (09) :1123-1132
[10]   DETERMINATION OF CADMIUM AND ZINC ISOTOPE RATIOS IN SHEEPS BLOOD AND ORGAN TISSUE BY ELECTROTHERMAL VAPORIZATION INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY [J].
GREGOIRE, DC ;
LEE, J .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (03) :393-397