Clinical effects of the levonorgestrel-releasing intrauterine device in patients with adenomyosis

被引:140
作者
Cho, SiHyun [1 ]
Nam, Anna [1 ]
Kim, HyeYeon [2 ]
Chay, DooByung [3 ]
Park, KiHyun [2 ]
Cho, Dong Je [2 ]
Park, YongWon [2 ]
Lee, ByungSeok [1 ]
机构
[1] Yonsei Univ, Coll Med, Yongdong Severance Hosp, Dept Obstet & Gynecol, Seoul 135720, South Korea
[2] Yonsei Univ, Coll Med, Severance Hosp, Dept Obstet & Gynecol, Seoul, South Korea
[3] Yonsei Univ, Coll Med, YongIn Severamce Hosp, Dept Obstet & Gynecol, Kyonggi Do, South Korea
关键词
adenomyosis; Doppler color flow; levonorgestrel intrauterine system; uterine artery; uterine volume;
D O I
10.1016/j.ajog.2007.10.798
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
OBJECTIVE: The aim of this study was to evaluate the long-term clinical effects of a levonorgestrel-releasing intrauterine device (LNG-IUD) on adenomyosis. STUDY DESIGN: A LNG-IUD was inserted into 47 patients who were diagnosed with adenomyosis. Uterine volume, uterine artery blood flow, pictorial blood loss assessment chart (PBAC) scores, and the degree of dysmenorrhea were evaluated before and 36 months after insertion of the LNG-IUD. RESULTS: Pain scores and PBAC scores dropped dramatically in 6 months and showed significant decrease after 36 months. A significant decrease in mean uterine volume was noted 12 months (156.85 +/- 49.79 mL to 118.64 +/- 41.36 mL; P <.001) and 24 months (128.84 +/- 48.70 mL; P <. 001) after LNG-IUD insertion, but no significant differences were noted at 36 months. The mean pulsatility indices of both uterine arteries increased significantly 12 months after insertion (P =.002 for right; P =.011 for left) and decreased after 24 months without significance. Uterine volume and uterine blood flow were negatively correlated (Pearson's correlation, P <. 05). Significant increase of uterine volume, pain scores, and PBAC scores were noted at 36 months compared with 12 months after insertion( P =.034,.021, and 001, respectively). CONCLUSION: For patients with clinical diagnosis of adenomyosis, the LNG-IUD is effective for the reduction of uterine volume with improvement of vascularity and relief of symptoms. However, the efficacy of LNG-IUD on uterine volume may begin to decrease 2 years after insertion.
引用
收藏
页码:373.e1 / 373.e7
页数:7
相关论文
共 30 条
[1]   THE NONSURGICAL DIAGNOSIS OF ADENOMYOSIS [J].
ARNOLD, LL ;
ASCHER, SM ;
SCHRUEFER, JJ ;
SIMON, JA .
OBSTETRICS AND GYNECOLOGY, 1995, 86 (03) :461-465
[2]  
AZZIZ R, 1989, OBSTET GYN CLIN N AM, V16, P221
[3]   The levonorgestrel intrauterine system in the management of menorrhagia [J].
Barrington, JW ;
BowenSimpkins, P .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1997, 104 (05) :614-616
[4]   Ultrasonography compared with magnetic resonance imaging for the diagnosis of adenomyosis: correlation with histopathology [J].
Bazot, M ;
Cortez, A ;
Darai, E ;
Rouger, J ;
Chopier, J ;
Antoine, JM ;
Uzan, S .
HUMAN REPRODUCTION, 2001, 16 (11) :2427-2433
[5]   Transvaginal ultrasound for diagnosis of adenomyosis: a review [J].
Dueholm, Margit .
BEST PRACTICE & RESEARCH IN CLINICAL OBSTETRICS & GYNAECOLOGY, 2006, 20 (04) :569-582
[6]   Treatment of adenomyosis-associated menorrhagia with a levonorgestrel-releasing intrauterine device [J].
Fedele, L ;
Bianchi, S ;
Raffaelli, R ;
Portuese, A ;
Dorta, M .
FERTILITY AND STERILITY, 1997, 68 (03) :426-429
[7]  
FEDELE L, 1992, FERTIL STERIL, V58, P94
[8]   Medical treatment of a grossly enlarged adenomyotic uterus with the levonorgestrel-releasing intrauterine system [J].
Fong, YF ;
Singh, K .
CONTRACEPTION, 1999, 60 (03) :173-175
[9]   The effect of the levonorgestrel intrauterine system on uterine artery blood flow 1 year after insertion [J].
Haberal, A ;
Kayikcioglu, F ;
Gunes, M ;
Kaplan, M ;
Ozdegirmenci, O .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2006, 27 (03) :316-319
[10]   ASSESSMENT OF MENSTRUAL BLOOD-LOSS USING A PICTORIAL CHART [J].
HIGHAM, JM ;
OBRIEN, PMS ;
SHAW, RW .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1990, 97 (08) :734-739