Issues in collecting, processing and storing human tissues and associated information to support biomedical research

被引:81
作者
Grizzle, William E. [1 ]
Bell, Walter C. [1 ]
Sexton, Katherine C. [2 ]
机构
[1] Univ Alabama, Dept Pathol, Div Anat Pathol, Birmingham, AL 35294 USA
[2] Univ Alabama, Ctr Comprehens Canc, Birmingham, AL 35294 USA
关键词
Tissue repositories; tissue banking; prospective collections; quality control; quality assurance; repository science; bias; clinical trials; epidemiology; annotation; material transfer agreement; shipping; informatics; safety; biohazards; security; difficult requests; caBIG; vocabulary; common data elements; chemical hazards; cost recovery; HIPAA; informed consent; demographics; clinical information; training; audits; good manufacturing practice; storage; specimen identification; services; PROSTATE-CANCER; GENE-EXPRESSION; MOLECULAR ANALYSIS; ISCHEMIA TIME; NETWORK; QUALITY; SERUM; ADENOCARCINOMA; SPECIMENS; HEDGEHOG;
D O I
10.3233/CBM-2011-0183
中图分类号
R73 [肿瘤学];
学科分类号
100214 [肿瘤学];
摘要
The availability of human tissues to support biomedical research is critical to advance translational research focused on identifying and characterizing approaches to individualized (personalized) medical care. Providing such tissues relies on three acceptable models -a tissue banking model, a prospective collection model and a combination of these two models. An unacceptable model is the "catch as catch can" model in which tissues are collected, processed and stored without goals or a plan or without standard operating procedures, i.e., portions of tissues are collected as available and processed and stored when time permits. In the tissue banking model, aliquots of tissues are collected according to SOPs. Usually specific sizes and types of tissues are collected and processed (e. g., 0.1 gm of breast cancer frozen in OCT). Using the banking model, tissues may be collected that may not be used and/or do not meet specific needs of investigators; however, at the time of an investigator request, tissues are readily available as is clinical information including clinical outcomes. In the model of prospective collection, tissues are collected based upon investigator requests including specific requirements of investigators. For example, the investigator may request that two 0.15 gm matching aliquots of breast cancer be minced while fresh, put in RPMI media with and without fetal calf serum, cooled to 4 degrees C and shipped to the investigator on wet ice. Thus, the tissues collected prospectively meet investigator needs, all collected specimens are utilized and storage of specimens is minimized; however, investigators must wait until specimens are collected, and if needed, for clinical outcome. The operation of any tissue repository requires well trained and dedicated personnel. A quality assurance program is required which provides quality control information on the diagnosis of a specimen that is matched specifically to the specimen provided to an investigator instead of an overall diagnosis of the specimen via a surgical pathology report. This is necessary because a specific specimen may not match the diagnosis of the case due to many factors such as necrosis, unsuspected tumor invasion of apparently normal tissue, and areas of fibrosis which are mistaken grossly for tumor. Aliquots for quality control (QC) may or may not be collected at the time of collection and in some cases, QC may not occur until specimens are distributed to investigators. In establishing a tumor repository, multiple issues need to be considered. These include the available resources, long term support, space and equipment. The needs of the potential users need to be identified as to the types of tissues and services needed and the annotation expected. Other specific issues to be considered include collection of specimens potentially infected with blood borne pathogens (e. g., hepatitis B), charge back mechanisms, informatics needs and support, and investigator requirements (e. g., recognition of repository contributions in publications). In general, the repository should not perform the research of the investigators, but should provide the infrastructure necessary to support the research of the investigator. Thus, the goals of the repository must be established. Similarly, ethical and regulatory issues must be evaluated. In general, tissue repositories need ethical (e. g., IRB) and privacy (e. g., HIPAA) review. Also, safety issues need to be considered as well as how biohazards will be addressed by investigator-users. Considerations involving the transfer of specimes to other organization usually require a material transfer agreement (MTA). A MTA should address biohazards as well as indemnification. Thus, many issues must be considered and addressed in order to establish and operate successfully a biorepository.
引用
收藏
页码:531 / 549
页数:19
相关论文
共 46 条
[1]
AAMODT R, 2007, REPORT PUBLIC RESPON
[2]
AAMODT R, 2008, TOOLS INVESTIGATORS
[3]
AAMODT RL, 2005, CELL PRESERV TECHNOL, V3, P48
[4]
[Anonymous], 2007, NCI BEST PRACT BIOSP
[5]
[Anonymous], AACR 96 ANN M
[6]
High levels of phosphorylated form of Akt-1 in prostate cancer and non-neoplastic prostate tissues are strong predictors of biochemical recurrence [J].
Ayala, G ;
Thompson, T ;
Yang, G ;
Frolov, A ;
Li, RL ;
Scardino, P ;
Ohori, M ;
Wheeler, T ;
Harper, W .
CLINICAL CANCER RESEARCH, 2004, 10 (19) :6572-6578
[7]
Stability of phosphoprotein as a biological marker of tumor signaling [J].
Baker, AF ;
Dragovich, T ;
Ihle, NT ;
Williams, R ;
Fenoglio-Preiser, C ;
Powis, G .
CLINICAL CANCER RESEARCH, 2005, 11 (12) :4338-4340
[8]
The efficient operation of the surgical pathology gross room [J].
Bell, W. C. ;
Young, E. S. ;
Billings, P. E. ;
Grizzle, W. E. .
BIOTECHNIC & HISTOCHEMISTRY, 2008, 83 (02) :71-82
[9]
Bell WC, 2010, METHODS MOL BIOL, V576, P1, DOI 10.1007/978-1-59745-545-9_1
[10]
How to Efficiently Obtain Human Tissues to Support Specific Biomedical Research Projects [J].
Bell, Walter C. ;
Sexton, Katherine C. ;
Grizzle, William E. .
CANCER EPIDEMIOLOGY BIOMARKERS & PREVENTION, 2009, 18 (06) :1676-1679