Sensitive and selective assay for fentanyl using gas chromatography with mass selective detection

被引:19
作者
Szeitz, A
Riggs, KW
HarveyClark, C
机构
[1] UNIV BRITISH COLUMBIA,FAC PHARMACEUT SCI,DIV CLIN PHARM,VANCOUVER,BC,CANADA
[2] UNIV BRITISH COLUMBIA,FAC PHARMACEUT SCI,DIV PHARMACEUT & BIOPHARMACEUT,VANCOUVER,BC,CANADA
[3] DALHOUSIE UNIV,OFF UNIV VETERINARIAN,HALIFAX,NS B3H 4H6,CANADA
来源
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS | 1996年 / 675卷 / 01期
关键词
fentanyl;
D O I
10.1016/0378-4347(95)00350-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A modified gas chromatographic assay, using mass-selective detection, has been developed for the quantitation of fentanyl in swine serum. Fentanyl and sufentanil, the internal standard, were extracted using a single-step liquid-liquid extraction with dichloromethane. Sensitivity and selectivity were improved by using electron-impact ionization (EI) in the selected-ion monitoring (SIM) mode, where fentanyl and sufentanil were monitored using the fragment ions at m/z 245 and 289, respectively. The limit of quantitation (LOQ) is 0.05 ng/ml, using 1 ml of sample, with a C.V. of 10.8% and a signal-to-noise ratio of 29. Standard curves were linear (r(2) = 0.999) over the working range of 0.05-1.5 ng/ml, using 1/y(2) as a weighting factor. Recoveries averaged 69.8 +/- 4.7%, 91.0 +/- 13.0% and 90.9 +/- 10.3% at serum concentrations of 1.5, 0.5 and 0.1 ng/ml, respectively. Intra- and inter-day variances, were <12% at 0.1 ng/ml, and <10% at concentrations of 0.5, 1 and 1.5 ng/ml. Bias was 6.2% at the LOQ and less than or equal to 12.8% at every other standard curve concentration. Applicability of the assay is demonstrated for the pharmacokinetic study of transdermally administered fentanyl in a postoperative swine.
引用
收藏
页码:33 / 42
页数:10
相关论文
共 23 条
[1]   RADICULAR ARTERY BLOOD NOW DOES NOT REDISTRIBUTE FENTANYL FROM THE EPIDURAL SPACE TO THE SPINAL-CORD [J].
BERNARDS, CM ;
SORKIN, LS .
ANESTHESIOLOGY, 1994, 80 (04) :872-878
[2]   SIMULTANEOUS DETERMINATION OF FENTANYL AND ALFENTANIL IN RAT-TISSUES BY CAPILLARY COLUMN GAS-CHROMATOGRAPHY [J].
BJORKMAN, S ;
STANSKI, DR .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1988, 433 :95-104
[3]  
CAMPISTRON G, 1988, CLIN CHEM, V34, P2157
[4]  
COOPER D, 1986, J FORENSIC SCI, V31, P511
[5]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF FENTANYL AND SUFENTANIL RETURNED FROM THE OPERATING-ROOM [J].
DEWELL, WM ;
KHANDAGHABADI, M ;
DSOUZA, MJ ;
SOLOMON, HM .
AMERICAN JOURNAL OF HOSPITAL PHARMACY, 1993, 50 (11) :2374-2375
[6]   REFRACTOMETRIC TESTING OF ALFENTANIL HYDROCHLORIDE, FENTANYL CITRATE, SUFENTANIL CITRATE, AND MIDAZOLAM HYDROCHLORIDE [J].
DONNELLY, AJ ;
NEWMAN, LM ;
PETRYNA, HM ;
IVANKOVICH, AD .
AMERICAN JOURNAL OF HOSPITAL PHARMACY, 1993, 50 (02) :298-300
[7]   GAS-CHROMATOGRAPHIC DETERMINATION OF FENTANYL AND ITS ANALOGS IN HUMAN-PLASMA [J].
GILLESPIE, TJ ;
GANDOLFI, AJ ;
MAIORINO, RM ;
VAUGHAN, RW .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1981, 5 (03) :133-137
[8]  
KENNEDY SK, 1990, PHARM BASICS THERAPE, P280
[9]   SIMULTANEOUS DETERMINATION OF FENTANYL AND ITS MAJOR METABOLITES AND FENTANYL ANALOGS USING GAS-CHROMATOGRAPHY AND NITROGEN-SELECTIVE DETECTION [J].
KINTZ, P ;
MANGIN, P ;
LUGNIER, AA ;
CHAUMONT, AJ .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1989, 489 (02) :459-461
[10]   STABILITY OF FENTANYL CITRATE IN GLASS AND PLASTIC CONTAINERS AND IN A PATIENT-CONTROLLED DELIVERY SYSTEM [J].
KOWALSKI, SR ;
GOURLAY, GK .
AMERICAN JOURNAL OF HOSPITAL PHARMACY, 1990, 47 (07) :1584-1587