A comparison of three balance methods for calculating ventilation rates in livestock buildings

被引:125
作者
Pedersen, S
Takai, H
Johnsen, JO
Metz, JHM
Koerkamp, PWGG
Uenk, GH
Phillips, VR
Holden, MR
Sneath, RW
Short, JL
White, RP
Hartung, J
Seedorf, J
Schroder, M
Linkert, KH
Wathes, CM
机构
[1] Danish Inst Anim Sci, Dept Agr Engn, Res Ctr Bygholm, DK-8700 Horsens, Denmark
[2] Inst Milieu Agr Tech, NL-6700 AA Wageningen, Netherlands
[3] Silsoe Res Inst, Silsoe MK45 4HS, Beds, England
[4] Tierarztlichen Hsch Hannover, Inst Tierhyg & Tierschutz, D-30559 Hannover, Germany
来源
JOURNAL OF AGRICULTURAL ENGINEERING RESEARCH | 1998年 / 70卷 / 01期
关键词
D O I
10.1006/jaer.1997.0276
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
Three methods for the calculation of the ventilation rate in Northern European livestock buildings were compared on the basis of the balances of animal heat, moisture and carbon dioxide for fattening pigs, dairy cattle and laying hens. The analyses were made on data sets from a collaborative project using literature values for the rates of production of heat, moisture and carbon dioxide. For heat and moisture production, it was found that the balance equations could be improved by including a correction for evaporation of water from fresh food, faeces and urine in livestock buildings, and by adjustment of the equations for partitioning total heat into sensible and latent heat for pigs and poultry. The correction, which is valid for climatic regions and production schemes that exist in Northern Europe, was calculated for each building in such a way that the heat and moisture balances gave the same ventilation rate. The three methods gave reliable results on a 24 h basis, except when there were small hourly differences between indoor and outdoor temperature (less than 2 degrees C), absolute humidity (less than 0.5 x 10(-3) kg of water/m(3)) and carbon dioxide concentration (less than 200 p.p.m.). On a 24 h basis the correlation coefficient (r(2)) between the ventilation rate based on carbon dioxide and on heat and moisture was 0.67 (p < 0.01) for fattening pigs and 0.90 (p < 0.001) for laying hens and dairy cows. For periods shorter than 24 h, a correction was needed for diurnal changes in animal heat, moisture and carbon dioxide production to achieve good agreement between calculated and measured ventilation rates. (C) 1998 Silsoe Research Institute.
引用
收藏
页码:25 / 37
页数:13
相关论文
共 17 条
[1]  
[Anonymous], P 12 CIGR WORLD C AG
[2]  
BERCKMANS D, 1992, INT WINT M NASHV TEN
[3]  
CHWALIBOG A, 1989, ARCH GEFLUGELKD, V53, P179
[4]  
*CIGR, 1984, CIGR REP CLIM AN HOU
[5]  
*CIGR, 1992, CIGR REP CLIM AN HOU
[6]  
DEATON JW, 1969, POULTRY SCI, V48, P1580
[7]   EVAPORATIVE COOLING IN FOWLS [J].
HUTCHINSON, JCD .
JOURNAL OF AGRICULTURAL SCIENCE, 1954, 45 (01) :48-59
[8]  
MEDWAY W, 1957, AM J PHYSIOL, V190, P137
[9]   ANIMAL ACTIVITY MEASURED BY INFRARED DETECTORS [J].
PEDERSEN, S ;
PEDERSEN, CB .
JOURNAL OF AGRICULTURAL ENGINEERING RESEARCH, 1995, 61 (04) :239-246
[10]  
Pedersen S., 1993, Livestock Environment IV. Proceedings of a conference held in Coventry, UK, 6-9 July 1993., P718