Comparison of the BacT/Alert PF pediatric FAN blood culture bottle with the standard pediatric blood culture bottle, the Pedi-BacT

被引:16
作者
Krisher, KK
Gibb, P
Corbett, S
Church, D
机构
[1] Childrens Med Ctr, Clin Microbiol Lab, Dallas, TX 75235 USA
[2] Calgary Lab Serv, Calgary, AB TC3 0J5, Canada
关键词
D O I
10.1128/JCM.39.8.2880-2883.2001
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
The performance of the BacT/Alert PF (Organon-Teknika Corp., Durham, N.C.), a new nonvented pediatric FAN blood culture bottle, was compared to that of the original pediatric bottle, the Pedi-BacT, with matched aerobic cultures obtained from two separate facilities. A total of 244 clinically significant isolates were recovered from 4,015 compliant pairs. Among the positive cultures, 170 (70%) isolates were detected in both the BacT/Alert PF and the Pedi-BacT bottles, while 47 (19%) isolates were recovered in the BacT/Alert PIT bottle only and 27 (11%) isolates were recovered in the Pedi-BacT bottle only. Although isolation of specific microorganisms was comparable for the two bottles, the total number of organisms recovered by the BacT/Alert PF was greater than that by the Pedi-BacT (P = 0.0272). In addition, more organisms were recovered by the BacT/Alert PF bottle from the blood of patients receiving antimicrobial therapy (P = 0.0180). Overall time to detection was similar for the two bottles; however, a significantly decreased mean time to detection was recorded for yeast from the BacT/Alert PF bottle (22.9 h; P = 0.0001) and staphylococci from the Pedi-BacT bottle (22.5 h; P = 0.0056). One false-negative culture and five false-positive cultures occurred with the Pedi-BacT bottle, compared to one false-positive culture with the BacT/Alert PF bottle. The BacT/Alert PF bottle is a reliable blood culture bottle for pediatric blood culture specimens and may offer improved recovery of microbes from patients on antimicrobial therapy. The use of the nonvented bottle will both facilitate bottle processing and decrease expenditures for materials due to the elimination of the venting needles required for the original vented bottles.
引用
收藏
页码:2880 / 2883
页数:4
相关论文
共 12 条
[1]  
ILLSTRUP DM, 1978, DETECTION SEPTICEMIA, P31
[2]   Effect of number of blood cultures and volume of blood on detection of bacteremia in children [J].
Isaacman, D ;
Karasic, RB ;
Reynolds, EA ;
Kost, SI .
JOURNAL OF PEDIATRICS, 1996, 128 (02) :190-195
[3]  
Kellogg JA, 2000, J CLIN MICROBIOL, V38, P2181
[4]  
KENNAUGH JK, 1984, PEDIATR INFECT DIS J, V3, P317, DOI 10.1097/00006454-198407000-00008
[5]   CONTROLLED CLINICAL-EVALUATION OF ISOLATOR AND ESP AEROBIC BLOOD CULTURE SYSTEMS FOR DETECTION OF BLOOD-STREAM INFECTIONS [J].
KIRKLEY, BA ;
EASLEY, KA ;
WASHINGTON, JA .
JOURNAL OF CLINICAL MICROBIOLOGY, 1994, 32 (06) :1547-1549
[6]   COMPARISON OF THE BACT ALERT PEDIATRIC BLOOD CULTURE SYSTEM, PEDI-BACT, WITH CONVENTIONAL CULTURE USING THE 20-MILLILITER BECTON-DICKINSON SUPPLEMENTED PEPTONE BROTH TUBE [J].
KRISHER, KK ;
WHYBURN, DR ;
KOEPNICK, FE .
JOURNAL OF CLINICAL MICROBIOLOGY, 1993, 31 (04) :793-797
[7]   Clinical importance of increased sensitivity of BacT/Alert FAN aerobic and anaerobic blood culture bottles [J].
McDonald, LC ;
Fune, J ;
Gaido, LB ;
Weinstein, MP ;
Reimer, LG ;
Flynn, TM ;
Wilson, ML ;
Mirrett, S ;
Reller, LB .
JOURNAL OF CLINICAL MICROBIOLOGY, 1996, 34 (09) :2180-2184
[8]   Controlled comparison of original vented aerobic FAN medium with new nonvented BacT/ALERT FA medium for culturing blood [J].
Mirrett, S ;
Everts, RJ ;
Reller, LB .
JOURNAL OF CLINICAL MICROBIOLOGY, 2001, 39 (06) :2098-2101
[9]   PEDIATRIC BLOOD CULTURES [J].
PAISLEY, JW ;
LAUER, BA .
CLINICS IN LABORATORY MEDICINE, 1994, 14 (01) :17-30
[10]   CONTROLLED EVALUATION OF BACT ALERT STANDARD AEROBIC AND FAN AEROBIC BLOOD CULTURE BOTTLES FOR DETECTION OF BACTEREMIA AND FUNGEMIA [J].
WEINSTEIN, MP ;
MIRRETT, S ;
REIMER, LG ;
WILSON, ML ;
SMITHELEKES, S ;
CHUARD, CR ;
JOHO, KL ;
RELLER, LB .
JOURNAL OF CLINICAL MICROBIOLOGY, 1995, 33 (04) :978-981