Mechanisms of dynamic force microscopy on polyvinyl alcohol: region-specific non-contact and intermittent contact regimes

被引:77
作者
Haugstad, G [1 ]
Jones, RR
机构
[1] Univ Minnesota, Ctr Interfacial Engn, Minneapolis, MN 55455 USA
[2] Fasson Roll N Amer, Avery Dennison, Painesville, OH 44077 USA
基金
美国国家科学基金会;
关键词
dynamic force microscopy; intermittent contact; tapping mode; ultrathin films; polyvinyl alcohol;
D O I
10.1016/S0304-3991(98)00073-4
中图分类号
TH742 [显微镜];
学科分类号
摘要
Dynamic force microscopy (DFM) phase signals were studied using heterogeneous films of polyvinyl alcohol (PVA). The phase was measured as a function of distance and drive frequency over regions of the film with different dissipative properties. When driving below the free resonance frequency at moderate amplitudes, the tip-sample interaction jumps between non-contact and intermittent contact regimes, giving rise to large, region-specific changes in phase within a single image. Amplitude damping largely determines the imaging regime. Resistance to intermittent contact can be overcome by selecting larger drive amplitudes at drive frequencies below the free resonance. Phase contrast then is related primarily to differences in viscoelastic loss. Upon nearing quasistatic contact, viscoelastic loss can produce a transition from intermittent contact to non-contact as the amplitude is heavily damped. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:77 / 86
页数:10
相关论文
共 24 条
[1]   Basic properties of dynamic force spectroscopy with the scanning force microscope in experiment and simulation [J].
Anczykowski, B ;
Kruger, D ;
Babcock, KL ;
Fuchs, H .
ULTRAMICROSCOPY, 1996, 66 (3-4) :251-259
[2]  
BACHELOT R, 1997, PROBE MICROSCOPY, V1, P89
[3]   Factors affecting the height and phase images in tapping mode atomic force microscopy. Study of phase-separated polymer blends of poly(ethene-co-styrene) and poly(2,6-dimethyl-1,4-phenylene oxide) [J].
Bar, G ;
Thomann, Y ;
Brandsch, R ;
Cantow, HJ ;
Whangbo, MH .
LANGMUIR, 1997, 13 (14) :3807-3812
[4]   Characterization of the morphologies and nanostructures of blends of poly(styrene) block-poly(ethene-co-but-1-ene)-block-poly(styrene) with isotactic and atactic polypropylenes by tapping-mode atomic force microscopy [J].
Bar, G ;
Thomann, Y ;
Whangbo, MH .
LANGMUIR, 1998, 14 (05) :1219-1226
[5]   How does a tip tap? [J].
Burnham, NA ;
Behrend, OP ;
Oulevey, F ;
Gremaud, G ;
Gallo, PJ ;
Gourdon, D ;
Dupas, E ;
Kulik, AJ ;
Pollock, HM ;
Briggs, GAD .
NANOTECHNOLOGY, 1997, 8 (02) :67-75
[6]  
de Gennes P.G., 1979, SCALING CONCEPTS POL
[7]   A magnetically driven oscillating probe microscope for operation in liquids [J].
Han, WH ;
Lindsay, SM ;
Jing, TW .
APPLIED PHYSICS LETTERS, 1996, 69 (26) :4111-4113
[8]  
HAUGSTAD G, UNPUB
[9]  
HAUGSTAD G, UNPUB LANGMUIR
[10]   Role of attractive forces in tapping tip force microscopy [J].
Kuhle, A ;
Sorensen, AH ;
Bohr, J .
JOURNAL OF APPLIED PHYSICS, 1997, 81 (10) :6562-6569