A selective voltammetric method for uric acid detection at Nafion®-coated carbon paste electrodes

被引:72
作者
Zen, JM [1 ]
Hsu, CT [1 ]
机构
[1] Natl Chung Hsing Univ, Dept Chem, Taichung 402, Taiwan
关键词
carbon paste electrode; Nafion (R); uric acid;
D O I
10.1016/S0039-9140(98)00004-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A square-wave voltammetric method together with Nafion(R)-coated carbon paste electrodes were used for the selective determination of uric acid in the presence of a high concentration of ascorbic acid. Since the oxidation potential of uric acid is about 200 mV more positive than that of ascorbic acid at the Nafion(R)-coated carbon paste electrode, the selectivity can be greatly improved simply by applying an electrolysis potential of + 0.4 V vs. Ag/AgCl where only ascorbic acid is oxidised. The acceptable tolerance of ascorbic acid concentration for the determination of uric acid is as high as 1.5 mM. With 30 s of electrolysis time, a linear calibration curve is obtained over the 0-50 mu M range in 0.05 hi citrate buffer solution, pH 4.0, with slope (mu A/mu M) and correlation coefficient of 0.34 and 0.9984, respectively. The detection limit (30) is 0.25 mu M. The practical analytical utility is illustrated by selective measurements of uric acid in human urine without any preliminary treatment. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1363 / 1369
页数:7
相关论文
共 15 条
[1]   AN IMPROVED VOLTAMMETRIC METHOD FOR THE DETERMINATION OF TRACE AMOUNTS OF URIC-ACID WITH ELECTROCHEMICALLY PRETREATED CARBON-PASTE ELECTRODES [J].
CAI, XH ;
KALCHER, K ;
NEUHOLD, C ;
OGOREVC, B .
TALANTA, 1994, 41 (03) :407-413
[2]  
DUTT V V S E, 1974, Analytical Chemistry, V46, P1777, DOI 10.1021/ac60348a041
[3]   DIFFERENTIAL-PULSE POLAROGRAPHY OF CADMIUM-URATE AND LEAD-URATE AND ADSORPTIVE STRIPPING VOLTAMMETRIC DETERMINATION OF URIC-ACID [J].
GANDOUR, MA ;
KASIM, EA ;
AMRALLAH, AH ;
FARGHALY, OA .
TALANTA, 1994, 41 (03) :439-444
[4]   VOLTAMMETRIC AND AMPEROMETRIC BEHAVIOR OF URIC-ACID AT BARE AND SURFACE-MODIFIED SCREEN-PRINTED ELECTRODES - STUDIES TOWARDS A DISPOSABLE URIC-ACID SENSOR [J].
GILMARTIN, MAT ;
HART, JP .
ANALYST, 1992, 117 (08) :1299-1303
[5]   AMPEROMETRIC SENSOR FOR HYPOXANTHINE AND XANTHINE BASED ON THE DETECTION OF URIC-ACID [J].
GONZALEZ, E ;
PARIENTE, F ;
LORENZO, E ;
HERNANDEZ, L .
ANALYTICA CHIMICA ACTA, 1991, 242 (02) :267-273
[6]   DETERMINATION OF URATE IN UNDILUTED WHOLE-BLOOD BY ENZYME ELECTRODE [J].
KEEDY, FH ;
VADGAMA, P .
BIOSENSORS & BIOELECTRONICS, 1991, 6 (06) :491-499
[7]   Poly(o-aminophenol)-modified bienzyme carbon paste electrode for the detection of uric acid [J].
Miland, E ;
Ordieres, AJM ;
Blanco, PT ;
Smyth, MR ;
Fagain, CO .
TALANTA, 1996, 43 (05) :785-796
[8]  
PARK G, 1972, ANAL LETT, V5, P887, DOI 10.1080/00032717208062153
[9]   THE APPLICATION OF QUATERNARY AMMONIUM IONIC POLYMERS TO ELECTROANALYSIS .2. VOLTAMMETRIC STUDIES WITH QUATERNARY AMMONIUM FUNCTIONALIZED POLYMER FILM-COATED ELECTRODES [J].
ROCHELEAU, MJ ;
PURDY, WC .
ELECTROANALYSIS, 1991, 3 (09) :935-939
[10]   OXIDASE PEROXIDASE BILAYER-MODIFIED ELECTRODES AS SENSORS FOR LACTATE, PYRUVATE, CHOLESTEROL AND URIC-ACID [J].
TATSUMA, T ;
WATANABE, T .
ANALYTICA CHIMICA ACTA, 1991, 242 (01) :85-89