DPSS yellow-green 561-nm lasers for improved fluorochrome detection by flow cytometry

被引:71
作者
Telford, W
Murga, M
Hawley, T
Hawley, R
Packard, B
Komoriya, A
Haas, F
Hubert, C
机构
[1] NCI, Expt Transplantat & Immunol Branch, Canc Res Ctr, NIH, Bethesda, MD 20892 USA
[2] George Washington Univ, Med Ctr, Flow Cytometry Core Facil, Washington, DC 20037 USA
[3] George Washington Univ, Med Ctr, Dept Anat & Cell Biol, Washington, DC 20037 USA
[4] Oncoimmunin Inc, Gaithersburg, MD USA
[5] Melles Griot Laser Grp Inc, Carlsbad, CA USA
关键词
solid state laser; yellow-green laser; phycoerythrin; DsRed;
D O I
10.1002/cyto.a.20182
中图分类号
Q5 [生物化学];
学科分类号
071010 [生物化学与分子生物学]; 081704 [应用化学];
摘要
Introduction: Blue-green 488-nm laser sources are widespread in flow cytometry but suffer some drawbacks for cell analysis, including their excitation of endogenous proteins (resulting in high cellular autofluorescence) and their less-than-optimal coincidence with the excitation maxima of commonly used fluorochromes, including the phycoerythrins (PE). Longer wavelength lasers such as green helium-neons and, more recently, diode-pumped solid state (DPSS) 532-nm sources have previously been employed to overcome these difficulties and improve overall sensitivity for PE. In this study, we evaluate an even longer wavelength DPSS 561-nm for its ability to improve PE and DsRed fluorescent protein detection sensitivity. Methods: A DPSS 561-nm laser emitting at 10 mW was mounted onto a BD LSR II. Mouse thymoma cells labeled with cell surface marker antibodies conjugated to the Rand B-forms of PE were analyzed and compared with conventional 488-nm excitation using the same bandpass filters and signal travel distances. A similar analysis was carried out with cell lines expressing the red fluorescent protein DsRed, several green-yellow excited low molecular weight fluorochromes, and a rhodamine-based caspase substrate. Additionally, cells labeled with PE and co-labeled with fluorescein or simultaneously expressing green fluorescent protein (GFP) were analyzed to determine if PE excitation at 561 nm with simultaneous fluorescein/GFP detection was feasible. Results: The DPSS 561-nm laser gave a several-fold improvement in the fluorochrome to autofluorescence ratios between PE-labeled cells and unlabeled controls. Analysis of cells expressing the fluorescent protein DsRed with the DPSS 561-nm source gave a 6-7-fold improvement in sensitivity over 488-nm excitation, and gave excellent excitation of yellow-green excited fluorochromes and rhodamine-based physiological probes. Yellow-green laser light also caused virtually no impingement on the spatially separated fluorescein/GFP detector, a significant problem with green laser sources, and also allowed simultaneous analysis of GFP and PE with virtually no signal overlap or requirement for color compensation. Conclusions: DPSS 561-nm laser excitation gave significantly improved sensitivity for both PE-labeled and DsRed expressing cells, with little contamination of a typical fluorescein/GFP detector. Published 2005 Wiley-Liss, Inc.(dagger).
引用
收藏
页码:36 / 44
页数:9
相关论文
共 17 条
[1]
[2]
A practical approach to multicolor flow cytometry for immunophenotyping [J].
Baumgarth, N ;
Roederer, M .
JOURNAL OF IMMUNOLOGICAL METHODS, 2000, 243 (1-2) :77-97
[3]
Quantitative comparison of long-wavelength Alexa Fluor dyes to Cy dyes: Fluorescence of the dyes and their bioconjugates [J].
Berlier, JE ;
Rothe, A ;
Buller, G ;
Bradford, J ;
Gray, DR ;
Filanoski, BJ ;
Telford, WG ;
Yue, S ;
Liu, JX ;
Cheung, CY ;
Chang, W ;
Hirsch, JD ;
Beechem, JM ;
Haugland, RP ;
Haugland, RP .
JOURNAL OF HISTOCHEMISTRY & CYTOCHEMISTRY, 2003, 51 (12) :1699-1712
[4]
Haugland R P, 1993, J Fluoresc, V3, P119, DOI 10.1007/BF00862728
[5]
Four-color flow cytometric detection of retrovirally expressed red, yellow, green, and cyan fluorescent proteins [J].
Hawley, TS ;
Telford, WG ;
Ramezani, A ;
Hawley, RG .
BIOTECHNIQUES, 2001, 30 (05) :1028-+
[6]
Rainbow reporters for multispectral marking and lineage analysis of hematopoietic stem cells [J].
Hawley, TS ;
Telford, WG ;
Hawley, RG .
STEM CELLS, 2001, 19 (02) :118-124
[7]
HAWLEY TS, 2004, FLOW CYTOMETRY PROTO, V263, P219
[8]
Engineering green fluorescent protein for improved brightness, longer wavelengths and fluorescence resonance energy transfer [J].
Hein, R ;
Tsien, RY .
CURRENT BIOLOGY, 1996, 6 (02) :178-182
[9]
Assessment of caspase activities in intact apoptotic thymocytes using cell-permeable fluorogenic caspase substrates [J].
Komoriya, A ;
Packard, BZ ;
Brown, MJ ;
Wu, ML ;
Henkart, PA .
JOURNAL OF EXPERIMENTAL MEDICINE, 2000, 191 (11) :1819-1828
[10]
Derivation of endothelial cells from CD34- umbilical cord blood [J].
Murga, M ;
Yao, L ;
Tosato, G .
STEM CELLS, 2004, 22 (03) :385-395