A field-deployable instrument for the measurement and speciation of arsenic in potable water

被引:92
作者
Huang, HL [1 ]
Dasgupta, PK [1 ]
机构
[1] Texas Tech Univ, Dept Chem & Biochem, Lubbock, TX 79409 USA
关键词
arsenic; stripping analysis; voltammetry; potentiometry; water analysis;
D O I
10.1016/S0003-2670(98)00649-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Extensive arsenic contamination of drinking water has been reported in many parts of the world. Trivalent As (As(III)) is regarded to be more toxic than pentavalent As (As(V)) and is slowly oxidized by dissolved oxygen to the latter. Collecting samples in the field and bringing them back to the laboratory is generally unsatisfactory for reliable analysis of As(III) and As(V), due to ongoing oxidative change of the sample. Even simple measurements of total As in the field is problematic due to the inadequate sensitivity of the available colorimetry based field kits. Anodic stripping analysis can be a good field technique to perform total and speciated measurements of dissolved inorganic As down to the 1 mu g/l level. We offer an inexpensive portable stripping voltammetric instrument with a simple procedure for the field analysis of As(III) and As(V). The water sample is acidified to pH 1-2. As(III) and As(V) can be deposited onto a gold film electrode at -0.2 and -1.6 V (vs. Ag/AgCl in 1 M HCl), respectively, then subsequently stripped in a medium of 4.5 M HCl. The As concentrations are determined by a standard addition method to account for any matrix effects. As(III) is first determined at a deposition potential of -0.2 V. Afterwards, all the As is oxidized to As(V) by the addition of a few drops of an oxidant, and total arsenic is determined by a deposition potential of -1.6 V. The original As(V) concentration in the sample is calculated by difference. Influences from foreign ions, organic compounds, pre-electrolysis potential and time and stripping medium have been investigated. The instrument is operated off a desktop or a notebook computer, equipped with an A/D-D/A card. The attainable limit of detection (LOD) is dependent on the deposition time, an LOD of 0.5 mu g/l As(III) or As(V) is obtained for a deposition time of 80 s. For field use. the entire instrument is packaged into a wheeled, padded carrying case (60 x24 x42 cm external dimensions). In addition to a laptop computer, the package weighs 6.5 kg and has an average power consumption of 3.5 W. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:27 / 37
页数:11
相关论文
共 36 条
[1]  
Adeloju SB, 1997, ANAL LETT, V30, P147, DOI 10.1080/00032719708002297
[2]  
BAHRI UC, 1993, IND J ENV PROTECTION, V13, P745
[3]  
BISWAS BK, 1997, CURR SCI, V73, P48
[4]  
BRAISER LL, 1996, DETROIT FREE PR 0108, pB3
[5]   SIGNIFICANCE OF EXPOSURE ASSESSMENT TO ANALYSIS OF CANCER RISK FROM INORGANIC ARSENIC IN DRINKING-WATER IN TAIWAN [J].
BROWN, KG ;
CHEN, CJ .
RISK ANALYSIS, 1995, 15 (04) :475-484
[6]   A DOSE-RESPONSE ANALYSIS OF SKIN-CANCER FROM INORGANIC ARSENIC IN DRINKING-WATER [J].
BROWN, KG ;
BOYLE, KE ;
CHEN, CW ;
GIBB, HJ .
RISK ANALYSIS, 1989, 9 (04) :519-528
[7]  
CHAKRABORTI D, 1998, INT C ARS POLL GROUN, P151
[8]   ARSENIC IN GROUND-WATER IN 6 DISTRICTS OF WEST-BENGAL, INDIA - THE BIGGEST ARSENIC CALAMITY IN THE WORLD .1. ARSENIC SPECIES IN DRINKING-WATER AND URINE OF THE AFFECTED PEOPLE [J].
CHATTERJEE, A ;
DAS, D ;
MANDAL, BK ;
CHOWDHURY, TR ;
SAMANTA, G ;
CHAKRABORTI, D .
ANALYST, 1995, 120 (03) :643-650
[9]  
CHIANG L, 1989, MIKROCHIM ACTA, V2, P149
[10]  
Chowdhury T.R., 1997, Arsenic, P93, DOI DOI 10.1007/978-94-011-5864-0_9