Fractures of ceramic bearings - History and present status

被引:101
作者
Hannouche, D
Nich, C
Bizot, P
Meunier, A
Nizard, RM
Sedel, L [1 ]
机构
[1] Hop Lariboisiere, F-75475 Paris, France
[2] Univ Denis Diderot, Paris, France
关键词
D O I
10.1097/01.blo.0000096806.78689.50
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
During a period of 25 years (1977 to 2001), 13 fractures of an alumina component were recorded retrospectively. During the same period, approximately 5500 alumina components were implanted (3300 with all-alumina bearings and 1200 with alumina-on-polyethylene). These events occurred in seven women and six men, with a mean age of 59 years and a mean weight of 71 kg. There were eight fractures of the femoral head and five fractures of the socket component. Three fractures clearly were related to trauma (two fractures of the socket and one fracture of the head) and two were related to an abnormal design (one 22-mm head and one extra-long neck). Five fractures occurred without any rational explanation, but two fractures that occurred in the early phase could have been caused by a weaker alumina material. Finally three recent fractures of the liner were related to a change in the design of the material. This has been corrected and no additional fractures were observed. Although this dramatic event is of concern, it is infrequent and easy to solve by a limited revision procedure if done emergently. This rare complication should be balanced with the other complications of THR, including mechanical failures and osteolysis, often described with metal-on-polyethylene prostheses.
引用
收藏
页码:19 / 26
页数:8
相关论文
共 44 条
[1]
Poor eight-year survival of cemented zirconia-polyethylene total hip replacements [J].
Allain, J ;
Le Mouel, S ;
Goutallier, D ;
Voisin, MC .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1999, 81B (05) :835-842
[2]
Failure of a stainless-steel femoral head of a revision total hip arthroplasty performed after a fracture of a ceramic femoral head - A case report [J].
Allain, J ;
Goutallier, D ;
Voisin, MC ;
Lemouel, S .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (09) :1355-1360
[3]
Archibeck MJ, 2000, CLIN ORTHOP RELAT R, P12
[4]
Bizot P, 2000, CLIN ORTHOP RELAT R, P134
[5]
Bizot P, 2000, CLIN ORTHOP RELAT R, P68
[6]
Bizot P, 2001, CLIN ORTHOP RELAT R, P85
[7]
BOUTIN P, 1981, REV CHIR ORTHOP, V67, P279
[8]
BOUTIN P, 1972, REV CHIR ORTHOP, V58, P229
[9]
THE USE OF DENSE ALUMINA ALUMINA CERAMIC COMBINATION IN TOTAL HIP-REPLACEMENT [J].
BOUTIN, P ;
CHRISTEL, P ;
DORLOT, JM ;
MEUNIER, A ;
DEROQUANCOURT, A ;
BLANQUAERT, D ;
HERMAN, S ;
SEDEL, L ;
WITVOET, J .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1988, 22 (12) :1203-1232
[10]
Zirconia as a sliding material -: Histologic, laboratory, and clinical data [J].
Cales, B .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2000, (379) :94-112