Reproducibilities and responses to food intake of GFR measured with chromium-51-EDTA and iohexol simultaneously and independently in normal subjects

被引:30
作者
Bird, Nicholas J. [1 ]
Peters, Christina [1 ]
Michell, A. Robert [2 ]
Peters, A. Michael [1 ]
机构
[1] Addenbrookes Hosp, Dept Nucl Med, Cambridge CB2 2QQ, England
[2] St Bartholomews Med Sch, William Harvey Res Inst, Dept Biochem Pharmacol, London, England
关键词
Cr-51-EDTA; extracellular fluid volume; glomerular filtration rate; iohexol; X-ray fluorescence;
D O I
10.1093/ndt/gfm825
中图分类号
R3 [基础医学]; R4 [临床医学];
学科分类号
1001 ; 1002 ; 100602 ;
摘要
Background. The aim was to evaluate the reproducibility of glomerular filtration rate (GFR) measured with iohexol and its response to food in a direct and independent comparison with Cr-51-ethylenediaminetetraacetic acid (EDTA), and examine the influence of two different whole body scaling parameters, body surface area (BSA) and extracellular fluid volume (ECV). Methods. Fasting and non-fasting GFR were measured in 20 normal volunteers using Cr-51-EDTA and iohexol, simultaneously injected into opposite arms. In 10, the fasting study was repeated. Venous samples obtained bilaterally 20, 40, 60, 120, 180 and 240 min after injection were assayed for indicator injected contralaterally-Cr-51-EDTA by well-counting and iohexol by X-ray fluorescence. GFR scaled to BSA was measured from six samples (GFR/BSA6) and from the last three (GFR/BSA3). GFR scaled to ECV was calculated as the mean transit time of marker using six samples (GFR/ECV6) or the last three (GFR/ECV3). Results. GFR/BSA3 was reproducible (coefficient of variations of 7.4% for Cr-51-EDTA and 7.6% for iohexol). Using Cr-51-EDTA, GFR/ECV3 (9.1%) and GFR/ECV6 (7.7%) were as reproducible as GFR/BSA3 and GFR/BSA6 (both 8.1%). However, GFR/ECV3 measured with iohexol had poorer reproducibility (16.8%). Food resulted in an increase in scaled GFR of about 5 ml/min but this was statistically significant only with respect to GFR/BSA (measured with Cr-51-EDTA or iohexol) and not GFR/ECV. Conclusions. Measured with Cr-51-EDTA, but not iohexol, GFR/ECV was as reproducible as GFR/BSA. GFR/BSA, measured with Cr-51-EDTA or iohexol, but not GFR/ECV, significantly increased after food.
引用
收藏
页码:1902 / 1909
页数:8
相关论文
共 43 条
[1]  
ALTMAN DG, 1991, PRACTICAL STAT MED R, P269
[2]   Glomerular filtration rate in severely overweight normotensive humans [J].
Anastasio, P ;
Spitali, L ;
Frangiosa, A ;
Molino, D ;
Stellato, D ;
Cirillo, E ;
Pollastro, RM ;
Capodicasa, L ;
Sepe, J ;
Federico, P ;
De Santo, NG .
AMERICAN JOURNAL OF KIDNEY DISEASES, 2000, 35 (06) :1144-1148
[3]   Transcutaneous renal function monitor: Precision during unsteady hemodynamics [J].
Bauman, LA ;
Watson, NE ;
Scuderi, PE ;
Peters, MA .
JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1998, 14 (04) :275-282
[4]   Comparison between slope-intercept and slope-only techniques for measuring glomerular filtration rate: Use of two independent markers and an independent arbiter [J].
Bird, Nicholas J. ;
Peters, Christina ;
Michell, A. Robert ;
Peters, A. Michael .
NUCLEAR MEDICINE COMMUNICATIONS, 2007, 28 (09) :711-718
[5]  
Bird NJ, 2003, J NUCL MED, V44, P1037
[6]  
BIRD NJ, IN PRESS SCAND J CLI
[7]   GFR measurement with iohexol and 51Cr-EDTA.: A comparison of the two favoured GFR markers in Europe [J].
Brandstrom, E ;
Grzegorczyk, A ;
Jacobsson, L ;
Friberg, P ;
Lindahl, A ;
Aurell, M .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 1998, 13 (05) :1176-1182
[9]   SELECTION OF ROUTINE METHOD FOR DETERMINATION OF GLOMERULAR-FILTRATION RATE IN ADULT PATIENTS [J].
BROCHNERMORTENSEN, J ;
RODBRO, P .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1976, 36 (01) :35-43
[10]   CAPILLARY-PERMEABILITY AND EXTRACELLULAR FLUID VOLUMES IN PREGNANCY-INDUCED HYPERTENSION [J].
BROWN, MA ;
ZAMMIT, VC ;
LOWE, SA .
CLINICAL SCIENCE, 1989, 77 (06) :599-604