Stereotactic excisional breast biopsy performed by interventional radiologists using the advanced breast biopsy instrumentation system

被引:18
作者
Damascelli, B
Frigerio, LF
Lanocita, R
Patelli, G
Viganotti, G
Di Tolla, G
Magnoni, S
Ticha, V
Galante, E
Attili, A
Saccozzi, R
Tomasich, G
机构
[1] Natl Canc Inst, Dept Radiol, I-20133 Milan, Italy
[2] Natl Canc Inst, Dept Surg Oncol, I-20133 Milan, Italy
[3] Natl Canc Inst, Dept Pathol, I-20133 Milan, Italy
关键词
D O I
10.1259/bjr.71.850.10211058
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The Advanced Breast Biopsy Instrumentation (ABBI) system, which uses surgical cannulas up to 20 mm in diameter, is an alternative to conventional surgical biopsy for the diagnosis of non-palpable breast lesions. Since the need for radiological skill outweighs the surgical content of the technique, we evaluated the feasibility of complete management of the procedure by interventional radiologists. 35 of the 111 patients originally scheduled for the procedure were excluded, three because the lesion could not be visualized and 32 because of insufficient thickness of the compressed boast. The procedure had to be abandoned in one case due to a technical failure. 77 stereotactic excisional breast biopsy procedures were performed using the ABBI system in 75 patients with suspicious non-palpable mammographic lesions. The procedure was carried out under local anaesthesia in the radiology department, using a dedicated Lorad (R) radiographic system. 31 (40%) masses without calcifications, 11 (14%) masses with calcifications and 35 (46%) clusters of microcalcifications without tumour mass were sampled. 43 (56%) benign lesions and 34 (44%) malignant lesions were diagnosed. The overall mean diameter of the lesions was 8.7 mm (range 3-22 mm). Pill 34 patients with malignancies and lobular carcinoma in situ subsequently underwent surgery, the results of which are reported. Three (4%) haematomas were detected and aspirated percutaneously. Two technical problems occurred: an ABBI cannula malfunction, and a computer failure of the digital imaging system during the procedure. The average procedure time was 80 min and the cost of each procedure was 2 800 000 Italian lire (1555 US$). It is concluded that tissue sampling with the ABBI system can be performed entirely by radiologists without significant problems. The procedure was well tolerated by all patients. The quality of the biopsy specimen was identical to that of a surgical specimen but with the advantages of stereotactic precision for localization of the lesion.
引用
收藏
页码:1003 / 1011
页数:9
相关论文
共 36 条
[1]   THE PREVALENCE OF CARCINOMA IN PALPABLE VS IMPALPABLE, MAMMOGRAPHICALLY DETECTED LESIONS [J].
BASSETT, LW ;
LIU, TH ;
GIULIANO, AE ;
GOLD, RH .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 157 (01) :21-24
[2]  
BASSETT LW, 1997, DIAGNOSIS DIS BREAST, P251
[3]  
BAUER TL, 1991, SURG GYNECOL OBSTET, V173, P482
[4]  
BRENNER RJ, 1991, CURR OPIN RADIOL, V3, P588
[5]   Stereotactic breast biopsy of atypical ductal hyperplasia and ductal carcinoma in situ lesions: Improved accuracy with directional, vacuum-assisted biopsy [J].
Burbank, F .
RADIOLOGY, 1997, 202 (03) :843-847
[6]  
Burbank F, 1996, AM SURGEON, V62, P128
[7]  
BURBANK F, 1996, SOC MIN INV THER 8 A, V5, P39
[8]   MAMMOGRAPHIC FOLLOW-UP OF NONPALPABLE LOW-SUSPICION BREAST ABNORMALITIES - ONE VERSUS 2 VIEWS [J].
DATOC, PD ;
HAYES, CW ;
CONWAY, WF ;
BOSCH, HA ;
NEAL, MP .
RADIOLOGY, 1991, 180 (02) :387-391
[9]   Nondiagnostic stereotaxic core breast biopsy: Results of rebiopsy [J].
Dershaw, DD ;
Morris, EA ;
Liberman, L ;
Abramson, AF .
RADIOLOGY, 1996, 198 (02) :323-325
[10]   NONPALPABLE BREAST-LESIONS - FINDINGS OF STEREOTAXIC NEEDLE-CORE BIOPSY AND FINE-NEEDLE ASPIRATION CYTOLOGY [J].
DOWLATSHAHI, K ;
YAREMKO, ML ;
KLUSKENS, LF ;
JOKICH, PM .
RADIOLOGY, 1991, 181 (03) :745-750