Coronary artery calcification measured at electron-beam CT: Agreement in dual scan runs and change over time

被引:78
作者
Bielak, LF
Sheedy, PF
Peyser, PA
机构
[1] Mayo Clin & Mayo Fdn, Dept Diagnost Radiol, Rochester, MN 55905 USA
[2] Univ Michigan, Dept Epidemiol, Ann Arbor, MI 48109 USA
关键词
computed tomography (CT); electron beam; coronary vessels; calcification; CT; statistical analysis;
D O I
10.1148/radiology.218.1.r01ja34224
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To use a recently described regression approach to evaluate agreement in the quantity of coronary artery calcification (CAC) with two consecutive acquisitions (dual scan runs) at electron-beam computed tomography (CT) in a quality-control program and to assess the change in CAC quantity over time in an individual. MATERIALS AND METHODS: A total of 1,376 asymptomatic research participants, who were not selected because they were at high risk for coronary artery disease, were examined for the quantity of CAC with dual scan runs at electron-beam CT. With these data, 95% limits of agreement were established and used to evaluate differences between scan runs performed approximately 3.5 years apart in 81 participants. RESULTS: The 95% limits or agreement depended on the mean quantity of CAC in the dual scan runs. Of the 81 participants whose examinations were approximately 3.5 years apart, 59 (73%) had no apparent change in CAC between the two examinations, 21 (26%) had large increases suggesting progression of CAC, and one (1%) had a targe decrease suggesting regression of CAC. CONCLUSION: The demonstrated method can be used to evaluate both agreement in dual scan runs and change in quantity of CAC overtime.
引用
收藏
页码:224 / 229
页数:6
相关论文
共 31 条
[1]   QUANTIFICATION OF CORONARY-ARTERY CALCIUM USING ULTRAFAST COMPUTED-TOMOGRAPHY [J].
AGATSTON, AS ;
JANOWITZ, WR ;
HILDNER, FJ ;
ZUSMER, NR ;
VIAMONTE, M ;
DETRANO, R .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (04) :827-832
[2]   Predictive value of electron beam computed tomography of the coronary arteries - 19-month follow-up of 1173 asymptomatic subjects [J].
Arad, Y ;
Spadaro, LA ;
Goodman, K ;
LledoPerez, A ;
Sherman, S ;
Lerner, C ;
Guerci, AD .
CIRCULATION, 1996, 93 (11) :1951-1953
[3]   SMALL LESIONS IN THE HEART IDENTIFIED AT ELECTRON-BEAM CT - CALCIFICATION OR NOISE [J].
BIELAK, LF ;
KAUFMANN, RB ;
MOLL, PP ;
MCCOLLOUGH, CH ;
SCHWARTZ, RS ;
SHEEDY, PF .
RADIOLOGY, 1994, 192 (03) :631-636
[4]   COMPARING 2 METHODS OF CLINICAL MEASUREMENT - A PERSONAL HISTORY [J].
BLAND, JM ;
ALTMAN, DG .
INTERNATIONAL JOURNAL OF EPIDEMIOLOGY, 1995, 24 :S7-S14
[5]   Measuring agreement in method comparison studies [J].
Bland, JM ;
Altman, DG .
STATISTICAL METHODS IN MEDICAL RESEARCH, 1999, 8 (02) :135-160
[6]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[7]   CORONARY-ARTERY CALCIFICATION DETECTED WITH ULTRAFAST CT AS AN INDICATION OF CORONARY-ARTERY DISEASE - WORK IN PROGRESS [J].
BREEN, JF ;
SHEEDY, PF ;
SCHWARTZ, RS ;
STANSON, AW ;
KAUFMANN, RB ;
MOLL, PP ;
RUMBERGER, JA .
RADIOLOGY, 1992, 185 (02) :435-439
[8]   Ultrafast computed tomography as a diagnostic modality in the detection of coronary artery disease: A multicenter study [J].
Budoff, MJ ;
Georgiou, D ;
Brody, A ;
Agatston, AS ;
Kennedy, J ;
Wolfkiel, C ;
Stanford, W ;
Shields, P ;
Lewis, RJ ;
Janowitz, WR ;
Rich, S ;
Brundage, BH .
CIRCULATION, 1996, 93 (05) :898-904
[9]   Effect of HMG-Coa reductase inhibitors on coronary artery disease as assessed by electron-beam computed tomography [J].
Callister, TQ ;
Raggi, P ;
Cooil, B ;
Lippolis, NJ ;
Russo, DJ .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (27) :1972-1978
[10]   Coronary artery disease: Improved reproducibility of calcium scoring with an electron-beam CT volumetric method [J].
Callister, TQ ;
Cooil, B ;
Raya, SP ;
Lippolis, NJ ;
Russo, DJ ;
Raggi, P .
RADIOLOGY, 1998, 208 (03) :807-814