Calcium-selective electrode based on polyaniline functionalized with bis[4-(1,1,3,3-tetramethylbutyl)phenyl]phosphate

被引:63
作者
Lindfors, T [1 ]
Ivaska, A [1 ]
机构
[1] Abo Akad Univ, Analyt Chem Lab, Proc Chem Grp, FIN-20500 Turku, Finland
基金
芬兰科学院;
关键词
electrically conducting polymer; soluble; polyaniline; calcium; all-solid-state; ion-selective electrode; potentiometry;
D O I
10.1016/S0003-2670(01)00996-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new Ca2+-selecrive polyaoiline (PANI)-based membrane material suitable far all-solid-state-sensor applications is presented. The membrane consists of electrically conducting PANI, bis[4-(1,1,3,3-tetramethylbutyl)phenyl]phosphoric acid (DTMBP-PO4H), dioctyl phenylphosphonate (DOPP) and cationic (tridodecylmethylammonium chloride, TDMACI) or anionic (potassium tetrakis(4-chlorophenyl)borate, KTpClPB) Lipophilic additives. PANI transforms the ionic response to an electronic signal and functions gt the same time as the membrane matrix. PANI is made soluble in dichloro methane (DCM) with the Ca2+-selective DTMBP-PO4H Ligand and membranes,can easily be prepared by drop-casting on glassy carbon (GC) substrates. PAM membranes with three different plasticizer (z) and additive (s) contents were studied (the molar ratios between the plasticizer or additive and DTMBP-PO4H are denoted as z and s, respectively). The best electrode performance, considering sensitivity and selectivity, was obtained for PANI membranes prepared with z = 0.90 and s = 0.10, containing KTpClPB as ionic additive. The Ca2+-sensitivity of this membrane was 27.8 +/- 0.2 mV/log a(Ca)(2+) (10(-1) to 10(-4) M CaCl2, LOD = 8 x 10(-7) M) in 0.1 M NaCl, and the selectivity coefficients (log K-Ca,j(pot)) towards j = Na+, K+, Li+, NH4+ and Mg2+, determined with the fixed interference method,were -3.9 +/- 0.1, -4.0 +/- 0.1, -3.5 +/- 0.1, -3.5 +/- 0.1, and -3.6 +/- 0.1, respectively. On the other hand, practically no redox or pH sensitivity was observed when TDMACI was used as the ionic additive. The PAM membranes were characterized with:potentiometry, electrochemical impedance spectroscopy (EIS) and UV-VIS. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:171 / 182
页数:12
相关论文
共 45 条
[1]   POTENTIOMETRIC ANION SELECTIVITY OF POLYMER MEMBRANES DOPED WITH PALLADIUM ORGANOPHOSPHINE COMPLEX [J].
BADR, IHA ;
MEYERHOFF, ME ;
HASSAN, SSM .
ANALYTICAL CHEMISTRY, 1995, 67 (15) :2613-2618
[2]   Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics [J].
Bakker, E ;
Buhlmann, P ;
Pretsch, E .
CHEMICAL REVIEWS, 1997, 97 (08) :3083-3132
[3]   Electrode modified by sulfonated calixarenes immobilized into a polypyrrole film: A step towards new ion-sensitive layers [J].
Bidan, G ;
Niel, MA .
SYNTHETIC METALS, 1997, 84 (1-3) :255-256
[4]   Potential stability of all-solid-state ion-selective electrodes using conducting polymers as ion-to-electron transducers [J].
Bobacka, J .
ANALYTICAL CHEMISTRY, 1999, 71 (21) :4932-4937
[5]   MECHANISM OF IONIC AND REDOX SENSITIVITY OF P-TYPE CONDUCTING POLYMERS .2. EXPERIMENTAL-STUDY OF POLYPYRROLE [J].
BOBACKA, J ;
GAO, ZQ ;
IVASKA, A ;
LEWENSTAM, A .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1994, 368 (1-2) :33-41
[6]   SINGLE PIECE ALL-SOLID-STATE ION-SELECTIVE ELECTRODE [J].
BOBACKA, J ;
LINDFORS, T ;
MCCARRICK, M ;
IVASKA, A ;
LEWENSTAM, A .
ANALYTICAL CHEMISTRY, 1995, 67 (20) :3819-3823
[7]   ALL-SOLID-STATE POLY(VINYL CHLORIDE) MEMBRANE ION-SELECTIVE ELECTRODES WITH POLY(3-OCTYLTHIOPHENE) SOLID INTERNAL CONTACT [J].
BOBACKA, J ;
MCCARRICK, M ;
LEWENSTAM, A ;
IVASKA, A .
ANALYST, 1994, 119 (09) :1985-1991
[8]   Plasticizer-free all-solid-state potassium-selective electrode based on poly(3-octylthiophene) and valinomycin [J].
Bobacka, J ;
Ivaska, A ;
Lewenstam, A .
ANALYTICA CHIMICA ACTA, 1999, 385 (1-3) :195-202
[9]   CALCIUM-SENSITIVE MICROELECTRODE SUITABLE FOR INTRACELLULAR MEASUREMENT OF CALCIUM(II) ACTIVITY [J].
BROWN, HM ;
PEMBERTON, JP ;
OWEN, JD .
ANALYTICA CHIMICA ACTA, 1976, 85 (02) :261-276
[10]   RECOMMENDATIONS FOR NOMENCLATURE OF ION-SELECTIVE ELECTRODES - (IUPAC RECOMMENDATIONS 1994) [J].
BUCK, RP ;
LINDNER, E .
PURE AND APPLIED CHEMISTRY, 1994, 66 (12) :2527-2536