Characterisation of reversed-phase liquid-chromatographic columns by chromatographic tests -: Comparing column classification based on chromatographic parameters and column performance for the separation of acetylsalicylic acid and related compounds

被引:57
作者
Dehouck, P
Visky, D
Vander Heyden, Y
Adams, E
Kovács, Z
Noszál, B
Massart, DL
Hoogmartens, J
机构
[1] Katholieke Univ Leuven, Lab Farmaceut Chem Anal Geneesmiddelen, B-3000 Louvain, Belgium
[2] Free Univ Brussels, Dept Pharmaceut & Biomed Anal, B-1090 Brussels, Belgium
[3] Semmelweis Univ, Dept Pharmaceut Chem, H-1092 Budapest, Hungary
关键词
stationary phases; LC; chromatographic tests; principal component analysis; column characterisation; selectivity; column performance; chemometrics; acetylsalicylic acid;
D O I
10.1016/j.chroma.2003.10.089
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Selection of RP-LC columns with suitable selectivity for a given analysis is difficult. For example, the European Pharmacopoeia (Ph. Eur.) and other official compendia for drug analysis only give a general description of the stationary phase in the operating procedure of a liquid chromatographic method. The need for a general test method to characterise RP-LC columns has been rising since the 1970s. A project to define a chromatographic procedure characterising RP-LC columns was started earlier. A procedure to measure test parameters was introduced and a classification of the columns, based on a minimal number of parameters, was obtained. This paper focuses on correlating the column classification with the selectivity obtained for a real separation. The separation of acetylsalicylic acid (aspirin) and related compounds was performed according to the Ph. Eur. monograph on the stationary phases previously characterised chromatographically. It was examined whether the classes of columns, determined using test parameter results, contain either suitable or unsuitable supports for the aspirin separation. The system suitability test prescribed by the Ph. Eur. in order to distinguish between suitable or unsuitable columns for this separation was also evaluated. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:189 / 200
页数:12
相关论文
共 45 条
[1]   SPECTROPHOTOMETRIC DETERMINATION OF MICROGRAM QUANTITIES OF ACETYLSALICYLIC ANHYDRIDE IN ACETYLSALICYLIC ACID [J].
BUNDGAARD, H ;
BUNDGAARD, C .
JOURNAL OF PHARMACY AND PHARMACOLOGY, 1973, 25 (08) :593-598
[2]  
CLAESSENS HA, 1993, LC GC EUR, V6, P692
[3]  
*COUNC EUR, 2002, EUR PHARM
[4]   Chromatographic classification of commercially available reverse-phase HPLC columns [J].
Cruz, E ;
Euerby, MR ;
Johnson, CM ;
Hackett, CA .
CHROMATOGRAPHIA, 1997, 44 (3-4) :151-161
[5]   A SIMPLE TEST TO CHARACTERIZE C8/C18-BONDED PHASES, PARTICULARLY FOR TOXICOLOGICAL SCREENING [J].
DALDRUP, T ;
KARDEL, B .
CHROMATOGRAPHIA, 1984, 18 (02) :81-83
[6]   CHEMOMETRIC CLASSIFICATION OF REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY COLUMNS [J].
DELANEY, MF ;
PAPAS, AN ;
WALTERS, MJ .
JOURNAL OF CHROMATOGRAPHY, 1987, 410 (01) :31-41
[7]   COMPARISON AND CHARACTERIZATION OF REVERSED PHASES [J].
ENGELHARDT, H ;
JUNGHEIM, M .
CHROMATOGRAPHIA, 1990, 29 (1-2) :59-68
[8]  
Engelhardt H., 1997, LC GC EUR, V10, P803
[9]  
Engelhardt H., 1999, INT LAB, P34
[10]   Chromatographic classification and comparison of commercially available reversed-phase liquid chromatographic columns using principal component analysis [J].
Euerby, M ;
Petersson, P .
JOURNAL OF CHROMATOGRAPHY A, 2003, 994 (1-2) :13-36