Extrarenal plasma clearance of iohexol, chromium-51-ethylenediaminetetraacetic acid, and inulin in anephric pigs

被引:22
作者
Frennby, B
Sterner, G
Almen, T
Chai, CM
Jonsson, BA
Mansson, S
机构
[1] LUND UNIV,MALMO HOSP,DEPT VASC & RENAL DIS,S-20502 MALMO,SWEDEN
[2] LUND UNIV,MALMO HOSP,DEPT EXPTL RES,S-20502 MALMO,SWEDEN
[3] LUND UNIV,MALMO HOSP,DEPT RADIAT PHYS,S-20502 MALMO,SWEDEN
关键词
extrarenal clearance; iohexol; chromium-51-ethylenediaminetetraacetic acid; glomerular filtration rate; inulin;
D O I
10.1016/S1076-6332(05)80382-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. To improve the measurement of the glomerular filtration rate (GFR), we determined the extrarenal plasma clearance of the GFR markers iohexol, chromium-51-ethylenediaminetetraacetic acid (Cr-51-EDTA), and inulin using 11 anephric pigs. Methods. After an intravenous (IV) bolus injection of the markers, the decay curves of their plasma concentrations were monitored for 29 hr by 16 plasma samples. The area under the curve (AUG; concentration of marker versus time) was calculated according to one- and three-compartment kinetics. The extrarenal clearance was calculated by dividing the dose of marker by the AUC. Results. In the three-compartment model, the median of the extrarenal clearances of iohexol, Cr-51-EDTA, and inulin were 0.87 ml . min(-1). 10 kg(-1) (range = 0.62-1.26 ml . min(-1). 10 kg(-1)), 0.79 ml . min(-1). 10 kg(-1) (range = 0.61-1.04 ml . min(-1). 10 kg(-1)), and 0.83 ml . min(-1). 10 kg(-1) (range = 0.65-1.17 ml . min(-1). 10 kg(-1)). The extrarenal clearance of Cr-51-EDTA was slightly lower than that of iohexol and inulin when measured with the three-compartment model (P =.015). There was no statistically significant difference between the two models of kinetics in calculating clearance of the same marker. Conclusion. Our results indicate that subtracting the median values of the extrarenal clearance of the markers from the total plasma clearance will provide GFR values closer to the ''true'' GFR. This technique might prove useful in GFR calculations in patients with a very low GFR (e.g., residual GFR in patients on dialysis).
引用
收藏
页码:145 / 153
页数:9
相关论文
共 27 条
[1]   VICARIOUS EXCRETION OF UROGRAPHIC MEDIA [J].
BECKER, JA ;
GREGOIRE, A ;
BERDON, W ;
SCHWARTZ, D .
RADIOLOGY, 1968, 90 (02) :243-&
[2]  
BOIJSEN M, 1987, ACTA RADIOL, V28, P581
[4]   COMPARISON BETWEEN TOTAL AND RENAL PLASMA CLEARANCE OF [EDTA-CR-51] [J].
BROCHNERMORTENSEN, J ;
RODBRO, P .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1976, 36 (03) :247-249
[5]   RELIABILITY OF ROUTINE CLEARANCE METHODS FOR ASSESSMENT OF GLOMERULAR-FILTRATION RATE IN ADVANCED RENAL-INSUFFICIENCY [J].
BROCHNERMORTENSEN, J ;
FREUND, LG .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1981, 41 (01) :91-97
[6]   CURRENT STATUS ON ASSESSMENT AND MEASUREMENT OF GLOMERULAR-FILTRATION RATE [J].
BROCHNERMORTENSEN, J .
CLINICAL PHYSIOLOGY, 1985, 5 (01) :1-17
[7]   IOHEXOL CLEARANCE FOR THE DETERMINATION OF GLOMERULAR-FILTRATION RATE IN CLINICAL-PRACTICE - EVIDENCE FOR A NEW GOLD STANDARD [J].
BROWN, SCW ;
OREILLY, PH .
JOURNAL OF UROLOGY, 1991, 146 (03) :675-679
[8]   EXTRA-RENAL EXCRETION OF DIATRIZOATE IN RENAL FAILURE [J].
CHAMBERLAIN, MJ ;
SHERWOOD, T .
BRITISH JOURNAL OF RADIOLOGY, 1966, 39 (466) :765-+
[9]  
DEGENAAR CP, 1987, CLIN CHEM JUN, P1070
[10]   MEASUREMENT OF RENAL-FUNCTION WITH IOHEXOL - A COMPARISON OF IOHEXOL, TC-99M-DTPA, AND CR-51 EDTA CLEARANCE [J].
EFFERSOE, H ;
ROSENKILDE, P ;
GROTH, S ;
JENSEN, LI ;
GOLMAN, K .
INVESTIGATIVE RADIOLOGY, 1990, 25 (07) :778-782