Precision, limit of detection and range of quantitation in competitive ELISA

被引:80
作者
Hayashi, Y
Matsuda, R
Maitani, T
Imai, K
Nishimura, W
Ito, K
Maeda, M
机构
[1] Natl Inst Hlth Sci, Setagaya Ku, Tokyo 1588501, Japan
[2] Kyoritsu Coll Pharmaceut Sci, Minato Ku, Tokyo 1058512, Japan
[3] Showa Univ, Sch Pharmaceut Sci, Shinagawa Ku, Tokyo 1428555, Japan
关键词
D O I
10.1021/ac0302859
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper develops a mathematical model for describing the within-plate variation as the RSD (relative standard deviation) of absorbance measurements in a wide concentration range in competitive ELISA and proposes a method for determining the limit of detection (LOD) and range of quantitation (ROQ). Tbe ELISA for 17alpha-hydroxyprogesterone is taken as an example. The theoretical RSD description involves analyte concentration as an independent variable and error sources as parameters which concern the pipetting and absorbance measurement. Our model can dispense with repeated experiments of real samples, but the error parameters should be determined experimentally. The theory is in good agreement with the experiments. The most influential error sources at low and high sample concentrations are shown to be the pipetting of a viscous solution of antiserum and the absorbance inherent to the wells of a plate, respectively. The LOD and ROQ are defined as the concentration with 30% RSD and the region with < 10% RSD, respectively, and are found in the theoretical plot of the RSD of concentration estimates vs concentration.
引用
收藏
页码:1295 / 1301
页数:7
相关论文
共 32 条
[1]   REVIEW AND TUTORIAL DISCUSSION OF NOISE AND SIGNAL-TO-NOISE RATIOS IN ANALYTICAL SPECTROMETRY .1. FUNDAMENTAL PRINCIPLES OF SIGNAL-TO-NOISE RATIOS [J].
ALKEMADE, CTJ ;
SNELLEMAN, W ;
BOUTILIER, GD ;
POLLARD, BD ;
WINEFORDNER, JD ;
CHESTER, TL ;
OMENETTO, N .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1978, 33 (08) :383-399
[2]  
[Anonymous], 1995, ANALYST, V120, P2303
[3]   CORRELATION OF QUANTITATIVE-ANALYSIS PRECISION TO RETENTION TIME PRECISION AND CHROMATOGRAPHIC RESOLUTION FOR RAPID, SHORT COLUMN ANALYSIS [J].
BAHOWICK, TJ ;
SYNOVEC, RE .
ANALYTICAL CHEMISTRY, 1995, 67 (03) :631-640
[5]   DETECTION LIMITS AND SPECTRAL INTERFERENCES IN ATOMIC-EMISSION SPECTROMETRY [J].
BOUMANS, PWJM .
ANALYTICAL CHEMISTRY, 1994, 66 (08) :A459-A467
[6]   REVIEW AND TUTORIAL DISCUSSION OF NOISE AND SIGNAL-TO-NOISE RATIOS IN ANALYTICAL SPECTROMETRY .2. FUNDAMENTAL PRINCIPLES OF SIGNAL-TO-NOISE RATIOS [J].
BOUTILIER, GD ;
POLLARD, BD ;
WINEFORDNER, JD ;
CHESTER, TL ;
OMENETTO, N .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1978, 33 (08) :401-416
[7]   PRECISION OF FLAME ATOMIC-ABSORPTION MEASUREMENTS OF ARSENIC, CADMIUM, CALCIUM, COPPER, IRON, MAGNESIUM, MOLYBDENUM, SODIUM, AND ZINC [J].
BOWER, NW ;
INGLE, JD .
ANALYTICAL CHEMISTRY, 1977, 49 (04) :574-579
[8]   PRECISION OF FLAME ATOMIC-ABSORPTION MEASUREMENTS OF COPPER [J].
BOWER, NW ;
INGLE, JD .
ANALYTICAL CHEMISTRY, 1976, 48 (04) :686-692
[9]   Assessment of assay precision: a case study of an ELISA for anti-pertussis antibody [J].
Das, REG .
BIOLOGICALS, 1999, 27 (02) :125-131
[10]  
DAY RA, 1991, QUANTITIVE ANAL