Font Size and Viewing Distance of Handheld Smart Phones

被引:181
作者
Bababekova, Yuliya [1 ]
Rosenfield, Mark [1 ]
Hue, Jennifer E. [1 ]
Huang, Rae R. [1 ]
机构
[1] SUNY Coll Optometry, New York, NY 10036 USA
关键词
accommodation; computer vision; convergence; nearwork; reading;
D O I
10.1097/OPX.0b013e3182198792
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. The use of handheld smart phones for written communication is becoming ubiquitous in modern society. The relatively small screens found in these devices may necessitate close working distances and small text sizes, which can increase the demands placed on accommodation and vergence. Methods. Font size and viewing distance were measured while subjects used handheld electronic devices in two separate trials. In the first study (n = 129), subjects were asked to show a typical text message on their own personal phone and to hold the device "as if they were about to read a text message." A second trial was conducted in a similar manner except subjects (n = 100) were asked to view a specific web page from the internet. Results. For text messages and internet viewing, the mean font size was 1.1 M (range, 0.7 to 2.1 M) and 0.8 M (range, 0.3 to 1.4 M), respectively. The mean working distance for text messages and internet viewing was 36.2 cm (range, 17.5 to 58.0 cm) and 32.2 cm (range, 19 to 60 cm), respectively. Conclusions. The mean font size for both conditions was comparable with newspaper print, although some subjects viewed text that was considerably smaller. However, the mean working distances were closer than the typical near working distance of 40 cm for adults when viewing hardcopy text. These close distances place increased demands on both accommodation and vergence, which could exacerbate symptoms. Practitioners need to consider the closer distances adopted while viewing material on smart phones when examining patients and prescribing refractive corrections for use at near, as well as when treating patients presenting with asthenopia associated with nearwork. (Optom Vis Sci 2011; 88: 795-797)
引用
收藏
页码:795 / 797
页数:3
相关论文
共 15 条
[1]  
American National Standards Institute/Human Factors and Ergonomics Society, 2007, 1002007 ANSIHFES
[2]  
[Anonymous], I LIVE FUTURE HERES
[3]  
Bailey IL., 2006, Borish's Clinical Refraction, V2nd, P217, DOI DOI 10.1016/B978-0-7506-7524-6.50012-0
[4]  
COLLIER JD, ACCOMMODATI IN PRESS
[5]  
DeMarco LM, 1997, J VISUAL IMPAIR BLIN, V91, P9
[6]   Interaction of screen distances, screen letter heights and source document distances [J].
Hennings, LK ;
Ye, N .
INTERACTING WITH COMPUTERS, 1996, 8 (04) :311-322
[7]  
*INT WORLD STATS, US POP STAT INT BIG
[8]  
Lay M., 2009, OPTOMETRY SCI TECHNI, P173
[9]   Prospective quantification of near work using the experience sampling method [J].
Rah, MJ ;
Mitchell, GL ;
Bullimore, MA ;
Mutti, MO ;
Zadnik, K .
OPTOMETRY AND VISION SCIENCE, 2001, 78 (07) :496-502
[10]  
Rideout V., GENERATION M2 MEDIA