Technical note: validation of a motion analysis system for measuring the relative motion of the intermediate component of a tripolar total hip arthroplasty prosthesis

被引:9
作者
Chen, QS
Lazennec, JY
Guyen, O
Kinbrum, A
Berry, DJ
An, KN
机构
[1] Mayo Clin, Coll Med, Div Orthoped Res, Biomech Lab, Rochester, MN 55905 USA
[2] Hop La Pitie Salpetriere, Dept Chirurg, Paris, France
关键词
tripolar; double mobility; total hip arthroplasty; prosthesis; motion analysis;
D O I
10.1016/j.medengphy.2004.11.008
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Tripolar total hip arthroplasty (THA) prosthesis had been suggested as a method to reduce the occurrence of hip dislocation and microseparation. Precisely measuring the motion of the intermediate component in vitro would provide fundamental knowledge for understanding its mechanism. The present study validates the accuracy and repeatability of a three-dimensional motion analysis system to quantitatively measure the relative motion of the intermediate component of tripolar total hip arthroplasty prostheses. Static and dynamic validations of the system were made by comparing the measurement to that of a potentiometer. Differences between the mean system-calculated angle and the angle measured by the potentiometer were within +/- 1 degrees. The mean within-trial variability was less than +/- 1 degrees. The mean slope was 0.9-1.02 for different angular velocities. The dynamic noise was within 1 degrees. The system was then applied to measure the relative motion of an eccentric THA prosthesis. The study shows that this motion analysis system provides an accurate and practical method for measuring the relative motion of the tripolar THA prosthesis in vitro, a necessary first step towards the understanding of its in vivo kinematics. (c) 2005 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:505 / 512
页数:8
相关论文
共 28 条
[1]   The effect of femoral component head size on posterior dislocation of the artificial hip joint [J].
Bartz, RL ;
Noble, PC ;
Kadakia, NR ;
Tullos, HS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (09) :1300-1307
[2]  
Berry D J, 2001, Instr Course Lect, V50, P265
[3]   A RADIOLOGICAL STUDY OF THE MOVEMENTS OF THE 2 COMPONENTS OF THE MONK PROSTHESIS (HARD-TOP DUO-PLEET) IN PATIENTS [J].
CHEN, SC ;
SARKAR, S ;
PELL, LH .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1980, 12 (03) :243-249
[4]   THE MOVEMENTS OF THE COMPONENTS OF THE HASTINGS BIPOLAR PROSTHESIS - A RADIOGRAPHIC STUDY IN 65 PATIENTS [J].
CHEN, SC ;
BADRINATH, K ;
PELL, LH ;
MITCHELL, K .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1989, 71 (02) :186-188
[5]  
FACKLER CD, 1980, CLIN ORTHOP RELAT R, P169
[6]  
Goetz DD, 1998, CLIN ORTHOP RELAT R, P171
[7]  
GRIGORIS P, 1994, CLIN ORTHOP RELAT R, P148
[8]   Muscular and neurologic function in patients with recurrent dislocation after total hip arthroplasty - A matched controlled study of 65 patients using dual-energy x-ray absorptiometry and postural stability tests [J].
Hedlundh, U ;
Karlsson, M ;
Ringsberg, K ;
Besjakov, J ;
Fredin, H .
JOURNAL OF ARTHROPLASTY, 1999, 14 (03) :319-325
[9]   Surgical experience related to dislocations after total hip arthroplasty [J].
Hedlundh, U ;
Ahnfelt, L ;
Hybbinette, CH ;
Weckstrom, J ;
Fredin, H .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1996, 78B (02) :206-209
[10]   Factors predisposing to dislocation after primary total hip arthroplasty - A multivariate analysis [J].
Jolles, BM ;
Zangger, P ;
Leyvraz, PF .
JOURNAL OF ARTHROPLASTY, 2002, 17 (03) :282-288