The analysis of myocardial proteins by infrared and ultraviolet laser desorption mass spectrometry

被引:30
作者
Sutton, CW [1 ]
Wheeler, CH [1 ]
U, S [1 ]
Corbett, JM [1 ]
Cottrell, JS [1 ]
Dunn, MJ [1 ]
机构
[1] NATL HEART & LUNG INST,IMPERIAL COLL,SCH MED,HEART SCI CTR,DIV CARDIOTHORAC SURG,HAREFIELD,MIDDX,ENGLAND
关键词
two-dimensional polyacrylamide gel electrophoresis; myocardial proteins; infrared laser; matrix-assisted laser desorption mass spectrometry;
D O I
10.1002/elps.1150180317
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The use of infrared (IR) and ultraviolet (UV) matrix-assisted laser desorption (MALDI) mass spectrometry to analyse myocardial proteins separated by two-dimensional (2-D) polyacrylamide gel electrophoresis (PAGE) is discussed. Proteins were electroblotted onto a FluoroTrans polyvinylidene difluoride (PVDF) membrane in order to facilitate analysis by MALDI, which represented the most efficient means of extracting large numbers of proteins simultaneously. Once on a FluoroTrans membrane, IR-MALDI was used to obtain spectra from selected protein spots, but no useful signals were obtained with UV MALDI. Spectra were generated from 46 of 50 spots analysed with protein masses from 13 to 82 kDa and isoelectric points (pI) 4.7-7.8. For those protein spots that had previously been characterised, and for which both sequence and post-translational modification data were known, IR-MALDI data was within plus or minus 0.5% of the expected mass. Some spots contained more than one protein signal, illustrating the increased information obtainable from MALDI, but also suggesting the limit of resolution of 2-D gels for separating large numbers of proteins. Attempts to digest proteins with specific proteases and generate peptide mass fingerprints by MALDI analysis on the membrane were unsuccessful with either IR or UV lasers. The peptides were extracted from the membrane and readily analysed by UV MALDI for peptide spectra. Poor data was obtained for peptide digests with IR-MALDI, probably because of matrix suppression by digest buffer, In order to obtain the maximum amount of information from blotted proteins, both IR and UV MALDI were required.
引用
收藏
页码:424 / 431
页数:8
相关论文
共 20 条
[1]  
ANNAN RS, 1996, P 44 ASMS C MASS SPE, P702
[2]   The human keratinocyte two-dimensional gel protein database (update 1995): Mapping components of signal transduction pathways [J].
Celis, JE ;
Rasmussen, HH ;
Gromov, P ;
Olsen, E ;
Madsen, P ;
Leffers, H ;
Honore, B ;
Dejgaard, K ;
Vorum, H ;
Kristensen, DB ;
Ostergaard, M ;
Haunso, A ;
Jensen, NA ;
Celis, A ;
Basse, B ;
Lauridsen, JB ;
Ratz, GP ;
Andersen, AH ;
Walbum, E ;
Kjaergaard, I ;
Andersen, I ;
Puype, M ;
VanDamme, J ;
Vandekerckhove, J .
ELECTROPHORESIS, 1995, 16 (12) :2177-+
[3]   THE HUMAN MYOCARDIAL 2-DIMENSIONAL GEL PROTEIN DATABASE - UPDATE-1994 [J].
CORBETT, JM ;
WHEELER, CH ;
BAKER, CS ;
YACOUB, MH ;
DUNN, MJ .
ELECTROPHORESIS, 1994, 15 (11) :1459-1465
[4]  
COTTRELL JS, 1994, PEPTIDE RES, V7, P115
[5]   IDENTIFICATION OF STRUCTURAL PROTEINS OF CHANNEL CATFISH VIRUS BY MASS-SPECTROMETRY [J].
DAVISON, AJ ;
DAVISON, MD .
VIROLOGY, 1995, 206 (02) :1035-1043
[6]   MASS-SPECTROMETRIC ANALYSIS OF BLOTTED PROTEINS AFTER GEL-ELECTROPHORETIC SEPARATION BY MATRIX-ASSISTED LASER DESORPTION IONIZATION [J].
ECKERSKORN, C ;
STRUPAT, K ;
KARAS, M ;
HILLENKAMP, F ;
LOTTSPEICH, F .
ELECTROPHORESIS, 1992, 13 (9-10) :664-665
[7]   Construction of HSC-2DPAGE: A two-dimensional gel electrophoresis database of heart proteins [J].
Evans, G ;
Wheeler, CH ;
Corbett, JM ;
Dunn, MJ .
ELECTROPHORESIS, 1997, 18 (3-4) :471-479
[8]   Peptide mass fingerprinting of chaperonin-containing TCP-1 (CCT) and copurifying proteins [J].
Hynes, G ;
Sutton, CW ;
U, S ;
Willison, KR .
FASEB JOURNAL, 1996, 10 (01) :137-147
[9]   OLIGOSACCHARIDE STRUCTURE AND AMINO-ACID SEQUENCE OF THE MAJOR GLYCOPEPTIDES OF MATURE HUMAN BETA-HEXOSAMINIDASE [J].
ODOWD, BF ;
CUMMING, DA ;
GRAVEL, RA ;
MAHURAN, D .
BIOCHEMISTRY, 1988, 27 (14) :5216-5226
[10]   Identification of human myocardial proteins separated by two-dimensional electrophoresis using an effective sample preparation for mass spectrometry [J].
Otto, A ;
Thiede, B ;
Muller, EC ;
Scheler, C ;
WittmannLiebold, B ;
Jungblut, P .
ELECTROPHORESIS, 1996, 17 (10) :1643-1650