Aerosol static electrification and its effects in inductively coupled plasma spectroscopy

被引:24
作者
Xu, JQ [1 ]
Balik, D [1 ]
Agnes, GR [1 ]
机构
[1] Simon Fraser Univ, Dept Chem, Burnaby, BC V5A 1S6, Canada
关键词
D O I
10.1039/b009014j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Reported are variations measured in tertiary aerosol laser scatter signal intensities in response to changes in the concentration of different dissolved solids in the starting solutions, and to varied DC potentials applied to a mesh screen positioned in a spray chamber. The scatter signal from an aerosol derived from a solution containing one of nine different ionic matrices would increase when the concentration of that matrix was increased from 10 to 100 mM, but there was no concentration dependence on the scatter signal when the matrix was non-ionic (sucrose). The tertiary aerosol droplet size distributions for three of these ionic matrices were then measured, and for each increase of the matrix concentration, there was an increased abundance of small droplets in the tertiary aerosol. We attribute the source of this droplet size distribution alteration to be the result of a change in the net charge acquired by the primary droplets at the nebulization step, instigated because of the change in the total concentration of dissolved solids in the starting solution. The net charge acquired by a primary droplet is a critical parameter, because during transport through the spray chamber desolvation can lead to a Coulomb fission event, a process that causes a droplet to split unevenly, releasing numerous new small droplets into the aerosol. We use this argument to explain how a change in the dissolved ionic solids concentration in the starting solution leads to a change in the frequency of Coulomb fission event occurrence within the secondary aerosol. The assumption that primary droplets carry net charge was then put to the test by incorporating a mesh screen into the spray chamber to which DC potentials were then applied. Each starting solution used in this work exhibited a large change in the tertiary aerosol in response to a DC biased mesh screen. In particular, there was decreased transmission for both large and small droplets in each of the tertiary aerosols studied, in response to increased electric field strengths in the spray chamber. These data provide strong evidence that static electrification of aerosols, with subsequent Coulomb fission event occurrence during aerosol transport, are ubiquitous factors in liquid sample introduction methodology for atomic spectroscopy.
引用
收藏
页码:715 / 723
页数:9
相关论文
共 31 条
[1]   PHASE DOPPLER SPRAY ANALYZER FOR SIMULTANEOUS MEASUREMENTS OF DROP SIZE AND VELOCITY DISTRIBUTIONS [J].
BACHALO, WD ;
HOUSER, MJ .
OPTICAL ENGINEERING, 1984, 23 (05) :583-590
[2]   INTERFERENCE FROM EASILY IONIZABLE ELEMENT MATRICES IN INDUCTIVELY COUPLED PLASMA EMISSION-SPECTROMETRY - A SPATIAL STUDY [J].
BLADES, MW ;
HORLICK, G .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1981, 36 (09) :881-900
[3]   SAMPLE INTRODUCTION - THE ACHILLES HEEL OF ATOMIC SPECTROSCOPY [J].
BROWNER, RF ;
BOORN, AW .
ANALYTICAL CHEMISTRY, 1984, 56 (07) :A786-&
[4]   EVOLUTION OF DROP SIZE DISTRIBUTIONS FOR PNEUMATICALLY GENERATED AEROSOLS IN INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY [J].
CANALS, A ;
HERNANDIS, V ;
BROWNER, RF .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1990, 45 (06) :591-601
[5]  
CASTELLAN GW, 1983, PHYSICAL CHEM
[6]   Effect of sodium during the aerosol transport and filtering in inductively coupled plasma atomic emission spectrometry [J].
Dubuisson, C ;
Poussel, E ;
Todoli, JL ;
Mermet, JM .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1998, 53 (04) :593-600
[7]   Computerized simulation of mixed-solute-particle vaporization in an inductively coupled plasma [J].
Horner, JA ;
Hieftje, GM .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1998, 53 (6-8) :1235-1259
[8]   On the evaporation of small ions from charged droplets [J].
IRIBARNE, JV ;
THOMSON, BA .
JOURNAL OF CHEMICAL PHYSICS, 1976, 64 (06) :2287-2294
[9]   FROM IONS IN SOLUTION TO IONS IN THE GAS-PHASE - THE MECHANISM OF ELECTROSPRAY MASS-SPECTROMETRY [J].
KEBARLE, P ;
TANG, L .
ANALYTICAL CHEMISTRY, 1993, 65 (22) :A972-A986
[10]   PHASE-DOPPLER DIAGNOSTIC STUDIES OF PRIMARY AND TERTIARY AEROSOLS PRODUCED BY A HIGH-EFFICIENCY NEBULIZER [J].
LIU, HY ;
MONTASER, A .
ANALYTICAL CHEMISTRY, 1994, 66 (19) :3233-3242