EOG correction: a new aligned-artifact average solution

被引:39
作者
Croft, RJ [1 ]
Barry, RJ [1 ]
机构
[1] Univ Wollongong, Dept Psychol, Wollongong, NSW 2522, Australia
来源
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY | 1998年 / 107卷 / 06期
关键词
aligned-artifact average; saccade; blink;
D O I
10.1016/S0013-4694(98)00087-X
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: In the field of EOG correction, discrepancies have been found between the propagation rates for different types and frequencies of eye movement. However, Croft and Barry demonstrated that these differences can be explained by the affect of EOG magnitude on the correction procedure (Croft, R.J. and Barry, R.J. EOG correction: a new perspective. Electroenceph. clin. Neurophysiol., 1998, 107: 387-394). This study utilized a new 'aligned-artifact average' technique (AAA) to examine whether propagation is constant across eye movement types and frequencies, and tested the AAA as an EOG correction tool. Methods: Two experiments manipulated interference levels in real data sets to determine if interference affected propagation coefficients (Bs). The third tested real data for the effect of forward propagation of eye movement related neural potentials on Bs, and the fourth utilized computer simulations to assess the effectiveness of the new AAA correction procedure. Results: Interference was found to inflate B at low EOG amplitude, and its removal removed B variation and inflation. The forward propagation of eye movement related neural potentials had very little effect on B. The AAA procedure produced near perfect corrections of the simulated data, superior to a comparison method. Conclusions: EOG propagation is constant across eye movement types and frequencies, and thus only one correction coefficient should be calculated and applied to data. The AAA method provides a more accurate correction and makes possible, for the first time, the adequate correction of posterior sites. (C) 1998 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:395 / 401
页数:7
相关论文
共 3 条
  • [1] EYEBLINK-RELATED POTENTIALS
    BERG, P
    DAVIES, MB
    [J]. ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1988, 69 (01): : 1 - 5
  • [2] EOG correction: a new perspective
    Croft, RJ
    Barry, RJ
    [J]. ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1998, 107 (06): : 387 - 394
  • [3] A NEW METHOD FOR OFF-LINE REMOVAL OF OCULAR ARTIFACT
    GRATTON, G
    COLES, MGH
    DONCHIN, E
    [J]. ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1983, 55 (04): : 468 - 484