Diffusion tensor MRI of the spinal cord

被引:49
作者
Ries, M
Jones, RA
Dousset, V
Moonen, CTW
机构
[1] Univ Bordeaux 2, CNRS, UMR 5536, Dept Resonance Magnet Syst Biol, F-33076 Bordeaux, France
[2] Hosp Pellegrin, Serv Neuroradiol, Bordeaux, France
关键词
diffusion; magnetic resonance imaging; spinal cord; EPI;
D O I
10.1002/1522-2594(200012)44:6<884::AID-MRM9>3.0.CO;2-Q
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
Apparent diffusion tensor (ADT) measurements on the spinal cord using a pulsed-field-gradient (PFG) multi-shot echo-planar imaging (EPI) sequence are presented. In a study of 10 healthy volunteers, the obtained rotationally invariant anisotropy information is compared to the results obtained by the rotationally dependent methods. The water diffusivity in the direction parallel to the fibers was found to be almost 2.5 times higher than the average diffusivity in directions perpendicular to the fibers and showed cylindrically symmetric anisotropy characteristics. The influence of partial volume effects and the point spread function on the measured results was evaluated, and it was the concluded that a resolution of 1 mm in the read and phase directions is required to obtain unbiased values. Possible clinical implications were demonstrated by investigating the diffusion characteristics of 10 patients suffering from narrowing of the cervical canal. The changes in the diffusion characteristics were found to be large enough to allow a robust detection of diffusion changes in the spine, even in cases in which conventional T-2 and T-1 weighted images were unable to detect any lesion. (C) 2000 Wiley-Liss, Inc.
引用
收藏
页码:884 / 892
页数:9
相关论文
共 31 条
[1]
A simplified method to measure the diffusion tensor from seven MR images [J].
Basser, PJ ;
Pierpaoli, C .
MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (06) :928-934
[2]
MR DIFFUSION TENSOR SPECTROSCOPY AND IMAGING [J].
BASSER, PJ ;
MATTIELLO, J ;
LEBIHAN, D .
BIOPHYSICAL JOURNAL, 1994, 66 (01) :259-267
[3]
Inferring microstructural features and the physiological state of tissues from diffusion-weighted images [J].
Basser, PJ .
NMR IN BIOMEDICINE, 1995, 8 (7-8) :333-344
[4]
Basser PJ, 1996, J MAGN RESON SER B, V111, P209, DOI [10.1006/jmrb.1996.0086, 10.1016/j.jmr.2011.09.022]
[5]
BASSER PJ, 1996, P 4 ANN M ISMRM NEW, P288
[6]
BRONSTEIN IN, 1991, HDB MATH, P22687
[7]
Castillo M, 1999, INT J NEURORADIOL, V5, P79
[8]
Clark CA, 1999, MAGN RESON MED, V41, P1269, DOI 10.1002/(SICI)1522-2594(199906)41:6<1269::AID-MRM26>3.0.CO
[9]
2-2
[10]
THE LOSS OF SMALL OBJECTS IN VARIABLE TE IMAGING - IMPLICATIONS FOR FSE, RARE, AND EPI [J].
CONSTABLE, RT ;
GORE, JC .
MAGNETIC RESONANCE IN MEDICINE, 1992, 28 (01) :9-24