The impact of a closed-loop electronic prescribing and administration system on prescribing errors, administration errors and staff time: A before-and-after study

被引:180
作者
Franklin, Bryony Dean
O'Grady, Kara
Donyai, Parastou
Jacklin, Ann
Barber, Nick
机构
[1] Univ London, Dept Pharm, NHS Trust, Sch Pharm,Hammersmith Hosp,Ctr Med Safety & Serv, London W12 0HS, England
[2] Kingston Univ, Dept Pharm, Surrey, England
[3] Univ London, Sch Pharm, Dept Practice & Policy, London W12 0HS, England
来源
QUALITY & SAFETY IN HEALTH CARE | 2007年 / 16卷 / 04期
关键词
D O I
10.1136/qshc.2006.019497
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Objectives: To assess the impact of a closed-loop electronic prescribing, automated dispensing, barcode patient identification and electronic medication administration record (EMAR) system on prescribing and administration errors, confirmation of patient identity before administration, and staff time. Design, setting and participants: Before-and-after study in a surgical ward of a teaching hospital, involving patients and staff of that ward. Intervention: Closed-loop electronic prescribing, automated dispensing, barcode patient identification and EMAR system. Main outcome measures: Percentage of new medication orders with a prescribing error, percentage of doses with medication administration errors (MAEs) and percentage given without checking patient identity. Time spent prescribing and providing a ward pharmacy service. Nursing time on medication tasks. Results: Prescribing errors were identified in 3.8% of 2450 medication orders pre-intervention and 2.0% of 2353 orders afterwards (p<0.001; chi(2) test). MAEs occurred in 7.0% of 1473 non-intravenous doses pre-intervention and 4.3% of 1139 afterwards (p = 0.005; chi(2) test). Patient identity was not checked for 82.6% of 1344 doses pre-intervention and 18.9% of 1291 afterwards (p, 0.001; chi(2) test). Medical staff required 15 s to prescribe a regular inpatient drug pre-intervention and 39 s afterwards (p = 0.03; t test). Time spent providing a ward pharmacy service increased from 68 min to 98 min each weekday (p = 0.001; t test); 22% of drug charts were unavailable pre-intervention. Time per drug administration round decreased from 50 min to 40 min (p = 0.006; t test); nursing time on medication tasks outside of drug rounds increased from 21.1% to 28.7% (p = 0.006; chi(2) test). Conclusions: A closed-loop electronic prescribing, dispensing and barcode patient identification system reduced prescribing errors and MAEs, and increased confirmation of patient identity before administration. Time spent on medication-related tasks increased.
引用
收藏
页码:279 / 284
页数:6
相关论文
共 36 条
[1]  
Almond M., 2002, BJHC&IM-British Journal of Healthcare Computing & Information Management, V19, P41
[2]  
[Anonymous], 2004, BUILD SAF NHS PAT IM
[3]  
[Anonymous], 2001, SPOONF SUG MED MAN N
[4]  
[Anonymous], 2000, Int J Pharm Pract
[5]   Improving prescribing using a rule based prescribing system [J].
Anton, C ;
Nightingale, PG ;
Adu, D ;
Lipkin, G ;
Ferner, RE .
QUALITY & SAFETY IN HEALTH CARE, 2004, 13 (03) :186-190
[6]   Qualitative evaluation of an electronic prescribing and administration system [J].
Barber, Nick ;
Cornford, Tony ;
Klecun, Ela .
QUALITY & SAFETY IN HEALTH CARE, 2007, 16 (04) :271-278
[7]   Effect of computerized physician order entry and a team intervention on prevention of serious medication errors [J].
Bates, DW ;
Leape, LL ;
Cullen, DJ ;
Laird, N ;
Petersen, LA ;
Teich, JM ;
Burdick, E ;
Hickey, M ;
Kleefield, S ;
Shea, B ;
Vander Vliet, M ;
Seger, DL .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1998, 280 (15) :1311-1316
[8]   Using information technology to reduce rates of medication errors in hospitals [J].
Bates, DW .
BRITISH MEDICAL JOURNAL, 2000, 320 (7237) :788-791
[9]   The impact of computerized physician order entry on medication error prevention [J].
Bates, DW ;
Teich, JM ;
Lee, J ;
Seger, D ;
Kuperman, GJ ;
Ma'Luf, N ;
Boyle, D ;
Leape, L .
JOURNAL OF THE AMERICAN MEDICAL INFORMATICS ASSOCIATION, 1999, 6 (04) :313-321
[10]  
BEECH EF, 1993, J SOC ADMIN PHARM, V10, P157