Intravascular ultrasound - Novel pathophysiological insights and current clinical applications

被引:608
作者
Nissen, SE
Yock, P
机构
[1] Cleveland Clin Fdn, Cleveland, OH 44195 USA
[2] Stanford Univ, Palo Alto, CA 94304 USA
关键词
ultrasonics; imaging; stents;
D O I
10.1161/01.CIR.103.4.604
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Intravascular ultrasound (IVUS) is a valuable adjunct to angiography, providing new insights in the diagnosis of and therapy for coronary disease. Angiography depicts only a 2D silhouette of the lumen, whereas IVUS allows tomographic assessment of lumen area, plaque size, distribution, and composition. The safety of IVUS is well documented, and the assessment of luminal dimensions represents an important application of this modality. Comparative studies show the greatest disparities between angiography and ultrasound after mechanical interventions. In young subjects, normal intimal thickness is typically approximate to0.15 mm. With IVUS, lipid-laden lesions appear hypoechoic, fibromuscular lesions generate low-intensity echoes, and fibrous or calcified tissues are echogenic. Calcium obscures the underlying wall (acoustic shadowing). The extent and severity of disease by angiography and ultrasound are frequently discrepant. Arterial remodeling refers to changes in vascular dimensions during the development of atherosclerosis. Ar diseased sites, the external elastic membrane may actually shrink in size, contributing to luminal stenosis. The interpretation of IVUS relies on simple visual inspection of acoustic reflections to determine plaque composition. However, different tissue components may look quite similar, and artifacts may adversely affect ultrasound images. IVUS commonly detects occult disease in angiographically "normal" sites. In ambiguous lesions, ultrasound permits lesion quantification, particularly for left main coronary disease. IVUS has emerged as the optimal method for the detection of transplant vasculopathy. An important potential application of ultrasound is the identification of atheromas at risk of rupture. The mechanisms of action of interventional devices have been elucidated using IVUS, and ultrasound is used by some operators to select the most suitable interventional device. IVUS-derived residual plaque burden is the most useful predictor of clinical outcome. In restenosis after balloon angioplasty, negative remodeling is a major mechanism of late lumen loss. IVUS is not routinely used for stent optimization, and there is no consensus regarding optimal procedural end points. Ultrasound has proven useful in evaluating brachytherapy. New and emerging applications for IVUS are continuing to evolve, particularly in atherosclerosis regression-progression trials.
引用
收藏
页码:604 / 616
页数:13
相关论文
共 93 条
  • [1] Acute and long/term results of an intravascular ultrasound-guided percutaneous transluminal coronary angioplasty/provisional stent implantation strategy
    Abizaid, A
    Pichard, AD
    Mintz, GS
    Abizaid, AS
    Klutstein, MW
    Satler, LF
    Mehran, R
    Leiboff, B
    Kent, KM
    Leon, MB
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1999, 84 (11) : 1298 - 1303
  • [2] Allen Kathleen M., 1996, Journal of the American College of Cardiology, V27, p138A
  • [3] CORONARY-ARTERY NARROWING IN CORONARY HEART-DISEASE - COMPARISON OF CINEANGIOGRAPHIC AND NECROPSY FINDINGS
    ARNETT, EN
    ISNER, JM
    REDWOOD, DR
    KENT, KM
    BAKER, WP
    ACKERSTEIN, H
    ROBERTS, WC
    [J]. ANNALS OF INTERNAL MEDICINE, 1979, 91 (03) : 350 - 356
  • [4] Batkoff BW, 1996, CATHETER CARDIO DIAG, V38, P238, DOI 10.1002/(SICI)1097-0304(199607)38:3<238::AID-CCD3>3.0.CO
  • [5] 2-9
  • [6] INTRAVASCULAR ULTRASOUND IMAGING IN PATIENTS WITH ACUTE MYOCARDIAL-INFARCTION
    BOCKSCH, W
    SCHARTL, M
    BECKMANN, S
    DREYSSE, S
    FLECK, E
    [J]. EUROPEAN HEART JOURNAL, 1995, 16 : 46 - 52
  • [7] QUALITATIVE AND QUANTITATIVE CONTRASTS IN THE MECHANISMS OF LUMEN ENLARGEMENT BY CORONARY BALLOON ANGIOPLASTY AND DIRECTIONAL CORONARY ATHERECTOMY
    BRADEN, GA
    HERRINGTON, DM
    DOWNES, TR
    KUTCHER, MA
    LITTLE, WC
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 23 (01) : 40 - 48
  • [8] Parametric (integrated backscatter and attenuation) images constructed using backscattered radio frequency signals (25-56 MHz) from human aortae in vitro
    Bridal, SL
    Fornes, P
    Bruneval, P
    Berger, G
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (02) : 215 - 229
  • [9] INTRACORONARY STENTING WITHOUT ANTICOAGULATION ACCOMPLISHED WITH INTRAVASCULAR ULTRASOUND GUIDANCE
    COLOMBO, A
    HALL, P
    NAKAMURA, S
    ALMAGOR, Y
    MAIELLO, L
    MARTINI, G
    GAGLIONE, A
    GOLDBERG, SL
    TOBIS, JM
    [J]. CIRCULATION, 1995, 91 (06) : 1676 - 1688
  • [10] Intravascular ultrasound-guided optimized stent deployment - Immediate and 6 months clinical and angiographic results from the Multicenter Ultrasound Stenting in Coronaries Study (MUSIC Study)
    de Jaegere, P
    Mudra, H
    Figulla, H
    Almagor, Y
    Doucet, S
    Penn, I
    Colombo, A
    Hamm, C
    Bartorelli, A
    Rothman, M
    Nobuyoshi, M
    Yamaguchi, T
    Voudris, V
    DiMario, C
    Makovski, S
    Hausmann, D
    Rowe, S
    Rabinovich, S
    Sunamura, M
    van Es, GA
    [J]. EUROPEAN HEART JOURNAL, 1998, 19 (08) : 1214 - 1223