Quantitative analysis of polycyclic aromatic hydrocarbons in water in the low-nanogram per liter range with two-step laser mass spectrometry

被引:18
作者
Emmenegger, C [1 ]
Kalberer, M [1 ]
Morrical, B [1 ]
Zenobi, R [1 ]
机构
[1] ETH, Swiss Fed Inst Technol, Dept Chem, CH-8093 Zurich, Switzerland
关键词
D O I
10.1021/ac0340197
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Polycyclic aromatic hydrocarbons (PAHs) are of major concern in all environmental compartments due to the mutagenic and carcinogenic properties of many PAHs. Two-step laser mass spectrometry (L2MS) is a sensitive and selective method to measure PAHs in complex solid matrixes. However, in most studies, L2MS was used for qualitative or semiquantitative analyses. Here we present for the first time a quantitative method analyzing PAHs in water at the nanogram per liter level. PAHs are extracted from a 30-mL water sample with a solid PVC membrane, which is then directly measured by L2MS without further treatment. Detection limits are in the low-nanogram per liter range (2-125 ng/L) for skeletal three- to six-ring PAHs. Extraction efficiencies of this method are between 75 and 90%. In a first application, samples from a wastewater treatment plant were measured, showing that microbial activities efficiently decrease PAH concentrations by 75-90%.
引用
收藏
页码:4508 / 4513
页数:6
相关论文
共 36 条
[1]   SELECTIVE DETECTION OF PHENOL IMPURITIES IN WATER [J].
ALIMPIEV, SS ;
MLYNSKI, VV ;
BELOV, ME ;
NIKIFOROV, SM .
ANALYTICAL CHEMISTRY, 1995, 67 (01) :181-186
[2]   LASER MULTI-PHOTON AND MULTISTEP PHOTO-IONIZATION OF MOLECULES AND MASS-SPECTROMETRY [J].
ANTONOV, VS ;
LETOKHOV, VS .
APPLIED PHYSICS, 1981, 24 (02) :89-106
[3]  
AREY J, 1998, HDB ENV CHEM PAHS RE, V3, pR1
[4]   UV irradiation of polycyclic aromatic hydrocarbons in ices: Production of alcohols, quinones, and ethers [J].
Bernstein, MP ;
Sandford, SA ;
Allamandola, LJ ;
Gillette, JS ;
Clemett, SJ ;
Zare, RN .
SCIENCE, 1999, 283 (5405) :1135-1138
[5]   Origin and distribution of polyaromatic hydrocarbons and polychlorobiphenyls in urban effluents to wastewater treatment plants of the Paris area (France) [J].
Blanchard, M ;
Teil, MJ ;
Ollivon, D ;
Garban, B ;
Chestérikoff, C ;
Chevreuil, M .
WATER RESEARCH, 2001, 35 (15) :3679-3687
[6]   Analysis of water contaminants and natural water samples using two-step laser mass spectrometry [J].
Bucheli, TD ;
Haefliger, OP ;
Dietiker, R ;
Zenobi, R .
ANALYTICAL CHEMISTRY, 2000, 72 (15) :3671-3677
[7]   CLOSE OVERLAPPING DISCRIMINATION OF POLYCYCLIC AROMATIC-HYDROCARBONS BY SYNCHRONOUS SCANNING AT VARIABLE-ANGLE SOLID-PHASE SPECTROFLUOROMETRY [J].
CAPITANVALLVEY, LF ;
DELOLMO, M ;
AVIDAD, R ;
NAVALON, A ;
DEORBE, I ;
VILCHEZ, JL .
ANALYTICA CHIMICA ACTA, 1995, 302 (2-3) :193-200
[8]   IDENTIFICATION OF COMPLEX AROMATIC-MOLECULES IN INDIVIDUAL INTERPLANETARY DUST PARTICLES [J].
CLEMETT, SJ ;
MAECHLING, CR ;
ZARE, RN ;
SWAN, PD ;
WALKER, RM .
SCIENCE, 1993, 262 (5134) :721-725
[9]   Trace level analysis of polycyclic aromatic hydrocarbons in surface waters by solid phase extraction (SPE) and gas chromatography-ion trap mass spectrometry (GC-ITMS) [J].
Crozier, PW ;
Plomley, JB ;
Matchuk, L .
ANALYST, 2001, 126 (11) :1974-1979
[10]   Isotopic and molecular fractionation in combustion; three routes to molecular marker validation, including direct molecular 'dating' (GC/AMS) [J].
Currie, LA ;
Klouda, GA ;
Benner, BA ;
Garrity, K ;
Eglinton, TI .
ATMOSPHERIC ENVIRONMENT, 1999, 33 (17) :2789-2806