Validation of capillary electrophoresis - mass spectrometry methods for the analysis of a pharmaceutical formulation

被引:52
作者
Geiser, L [1 ]
Rudaz, S [1 ]
Veuthey, JL [1 ]
机构
[1] Univ Geneva, Sch Pharm, Lab Pharmaceut Analyt Chem, CH-1211 Geneva 4, Switzerland
关键词
capillary electrophoresis; electrospray ionization; mass spectrometer; pharmaceutical analysis; validation;
D O I
10.1002/elps.200305564
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The coupling of capillary electrophoresis (CE) to mass spectrometry (MS) with an electro-spray ionization (ESI) technique is generally performed for qualitative applications, and only few quantitative results have been reported. This paper investigates the validation of a CE-ESI-MS method for the analysis of a pharmaceutical formulation containing lidocaine. Some important ESI criteria are discussed including sheath-liquid composition, nebulizing gas pressure and position of the CE capillary outlet. After optimization of these parameters, an intermediate precision of about 5% was achieved. The latter, as well as efficiency and resolution, were compared to those achieved with UV detection. Besides, a multiple injection procedure was developed to reduce analysis time per sample and was successfully applied to both UV and MS detectors. The validation results achieved by multiple injections were identical to those obtained with classical injection, but afforded a gain of time by a factor of 2.5.
引用
收藏
页码:3049 / 3056
页数:8
相关论文
共 54 条
[1]   HIGH-VOLTAGE CAPILLARY ZONE ELECTROPHORESIS - OPERATING PARAMETERS EFFECTS ON ELECTROENDOSMOTIC FLOWS AND ELECTROPHORETIC MOBILITIES [J].
ALTRIA, KD ;
SIMPSON, CF .
CHROMATOGRAPHIA, 1987, 24 :527-532
[2]  
Altria KD, 1996, J CAPILLARY ELECTROP, V3, P13
[3]   The use of a short-end injection procedure to achieve improved performance in capillary electrophoresis [J].
Altria, KD ;
Kelly, MA ;
Clark, BJ .
CHROMATOGRAPHIA, 1996, 43 (3-4) :153-158
[4]   Current applications in the analysis of pharmaceuticals by capillary electrophoresis. I [J].
Altria, KD ;
Kelly, MA ;
Clark, BJ .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1998, 17 (04) :204-214
[5]  
Altria KD, 2002, LC GC EUR, V15, P588
[6]   AN OVERVIEW OF METHOD VALIDATION AND SYSTEM SUITABILITY ASPECTS IN CAPILLARY ELECTROPHORESIS [J].
ALTRIA, KD ;
RUDD, DR .
CHROMATOGRAPHIA, 1995, 41 (5-6) :325-331
[7]  
ALTRIA KD, 2001, LC GC EUR, V14, P736
[8]  
[Anonymous], STP PHARM PRATIQUES
[9]   Quantitative capillary electrophoresis-ion-trap mass spectrometry determination of methylphenidate in human urine [J].
Bach, GA ;
Henion, J .
JOURNAL OF CHROMATOGRAPHY B, 1998, 707 (1-2) :275-285
[10]   Recent advances in capillary electrophoresis electrospray mass spectrometry [J].
Banks, JF .
ELECTROPHORESIS, 1997, 18 (12-13) :2255-2266