Value of perfusion lung scan in the diagnosis of pulmonary embolism: Results of the Prospective Investigative Study of Acute Pulmonary Embolism Diagnosis (PISA-PED)

被引:268
作者
Miniati, M [1 ]
Pistolesi, M [1 ]
Marini, C [1 ]
DiRicco, G [1 ]
Formichi, B [1 ]
Prediletto, R [1 ]
Allescia, G [1 ]
Tonelli, L [1 ]
Sostman, HD [1 ]
Giuntini, C [1 ]
机构
[1] UNIV PISA,IST CLIN MED 2,I-56100 PISA,ITALY
关键词
D O I
10.1164/ajrccm.154.5.8912753
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
To assess the value of perfusion lung scan in the diagnosis of pulmonary embolism, we prospectively evaluated 890 consecutive patients with suspected pulmonary embolism. Prior to lung scanning, each patient was assigned a clinical probability of pulmonary embolism (very likely, possible, unlikely). Perfusion scans were independently classified as follows: (1) normal, (2) near-normal, (3) abnormal compatible with pulmonary embolism (PE+: single or multiple wedge-shaped perfusion defects), or (4) abnormal not compatible with pulmonary embolism (PE-: perfusion defects other than wedge-shaped). The study design required pulmonary angiography and clinical and scintigraphic follow-up in all patients with abnormal scans. Of 890 scans, 220 were classified as normal/or near-normal and 670 as abnormal. A definitive diagnosis was established in 563 (84%) patients with abnormal scans. The overall prevalence of pulmonary embolism was 39%. Most patients with angiographically proven pulmonary embolism had PE+ scans (sensitivity: 92%). Conversely, most patients without emboli on angiography had PE- scans (specificity: 87%). A PE+ scan associated with a very likely or possible clinical presentation of pulmonary embolism had positive predictive values of 99 and 92%, respectively. A PE- scan paired with an unlikely clinical presentation had a negative predictive value of 97%. Clinical assessment combined with perfusion-scan evaluation established or excluded pulmonary embolism in the majority of patients with abnormal scans. Our data indicate that accurate diagnosis of pulmonary embolism is possible by perfusion scanning alone, without ventilation imaging. Combining perfusion scanning with clinical assessment helps to restrict the need for angiography to a minority of patients with suspected pulmonary embolism.
引用
收藏
页码:1387 / 1393
页数:7
相关论文
共 30 条
[1]   ROLE OF XE-133 VENTILATION STUDIES IN SCINTIGRAPHIC DETECTION OF PULMONARY-EMBOLISM [J].
ALDERSON, PO ;
RUJANAVECH, N ;
SECKERWALKER, RH ;
MCKNIGHT, RC .
RADIOLOGY, 1976, 120 (03) :633-640
[2]   COMPARATIVE ANALYSIS OF PULMONARY PERFUSION SCANS WITH PULMONARY ANGIOGRAMS - FROM A NATIONAL COOPERATIVE STUDY [J].
BELL, WR ;
SIMON, TL .
AMERICAN HEART JOURNAL, 1976, 92 (06) :700-706
[3]   VENTILATION-PERFUSION STUDIES IN SUSPECTED PULMONARY-EMBOLISM [J].
BIELLO, DR ;
MATTAR, AG ;
MCKNIGHT, RC ;
SIEGEL, BA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1979, 133 (06) :1033-1037
[4]  
BONE RC, 1993, ARCH INTERN MED, V153, P2621
[5]   PROSPECTIVE-STUDY OF A STANDARDIZED QUESTIONNAIRE TO IMPROVE CLINICAL ESTIMATE OF PULMONARY-EMBOLISM [J].
CELI, A ;
PALLA, A ;
PETRUZZELLI, S ;
CARROZZI, L ;
JACOBSON, A ;
CELLA, G ;
GIUNTINI, C ;
SASAHARA, AA .
CHEST, 1989, 95 (02) :332-337
[6]   VENTILATORY LUNG SCAN IN DIAGNOSIS OF PULMONARY EMBOLISM [J].
DENARDO, GL ;
GOODWIN, DA ;
RAVASINI, R ;
DIETRICH, PA .
NEW ENGLAND JOURNAL OF MEDICINE, 1970, 282 (24) :1334-&
[7]   REVEREND BAYES SILENT MAJORITY - AN ALTERNATIVE FACTOR AFFECTING SENSITIVITY AND SPECIFICITY OF EXERCISE ELECTROCARDIOGRAPHY [J].
DIAMOND, GA .
AMERICAN JOURNAL OF CARDIOLOGY, 1986, 57 (13) :1175-1180
[8]   LARGE SAMPLE STANDARD ERRORS OF KAPPA AND WEIGHTED KAPPA [J].
FLEISS, JL ;
COHEN, J ;
EVERITT, BS .
PSYCHOLOGICAL BULLETIN, 1969, 72 (05) :323-&
[9]  
FLEISS JL, 1971, PSYCHOL BULL, V76, P378, DOI 10.1037/h0031619
[10]   LUNG SCAN PATTERNS IN PULMONARY-EMBOLISM VERSUS THOSE IN CONGESTIVE HEART-FAILURE AND EMPHYSEMA [J].
GILDAY, DL ;
JAMES, AE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1972, 115 (04) :739-&