Longitudinal ruptures of polyester knitted vascular prostheses

被引:43
作者
Chakfe, N
Riepe, G
Dieval, F
Le Magnen, JF
Wang, L
Urban, E
Beaufigeau, M
Durand, B
Imig, H
Kretz, JG
机构
[1] Hop Univ Strasbourg, Dept Cardiovasc Surg, F-67091 Strasbourg, France
[2] Grp Europeen Rech Protheses Appl Chirurg Vasc, GEPROVAS, Strasbourg, France
[3] Lab Phys & Mecan Text, Hamburg, Germany
[4] GPL, Hamburg, Germany
[5] Dept Gen Thorac & Vasc Surg, Hamburg, Germany
[6] French Soc Vasc Surg, Comite Ad Hoc Surveillance Protheses Vasc, Mulhouse, France
关键词
D O I
10.1067/mva.2001.113493
中图分类号
R61 [外科手术学];
学科分类号
摘要
Aim: The purpose of the study was the characterization of a type of rupture occurring on warp-knitted polyester vascular prostheses. Materials and Methods: We studied 20 cases of warp-knitted polyester vascular prostheses that were explanted from humans that showed a longitudinal rupture as a part of a collaborative retrieval program. All the prostheses were immediately fixed in a 10% formaldehyde solution after their explantation in the operating room. The clinical data of these cases were recorded. The explants were photographed, washed to eliminate the surrounding tissues, and photographed again. The ruptures were characterized with macroscopic examination, optical stereomicroscopy, and scanning electron microscopy. Results: The mean duration of implantation of the prostheses was 16.0 +/- 3.3 years (range, 9-20.7 years). The prostheses were Cooley Double Velour (n = 15) and Microvel Double Velour (n = 5). There were 16 aortobifemoral bypass grafts, 1 aorto-biiliac, 1 aorto-aortic, 1 iliofemoral, and 1 axillobifemoral. The longitudinal ruptures occurred on two specific parts of the prostheses: the guide line (6 cases) and the remeshing line(ll cases). In three cases both lines were affected. Scanning electron microscopy showed major degradation of the trilobar filaments of the velour and gradual ruptures of the flat filaments of the remeshing and guide lines. Conclusions: In this study, we have identified a specific mechanism of late (9-20 years) longitudinal rupture of knitted polyester prostheses consisting of degradation of the polyester filaments along the remeshing and guide lines that run the length of the graft.
引用
收藏
页码:1015 / 1021
页数:7
相关论文
共 19 条
[1]
BERGER K, 1981, ANN SURG, V193, P477
[2]
BLUMENBERG RM, 1977, SURGERY, V81, P493
[3]
COOKE PA, 1974, ARCH SURG-CHICAGO, V103, P101
[4]
Guidoin R, 1990, CURRENT THERAPY VASC, P324
[5]
HUSSEY HH, 1976, JAMA-J AM MED ASSOC, V235, P848
[6]
KING MW, 1985, ASTM STP, V859, P294
[7]
LYNN RB, 1979, CAN J SURG, V22, P593
[8]
NUCHO RC, 1984, ARCH SURG-CHICAGO, V119, P1182
[9]
Nunn D B, 1999, Semin Vasc Surg, V12, P83
[10]
POST-OPERATIVE ALTERATIONS IN SIZE OF DACRON AORTIC GRAFTS - ULTRASONIC EVALUATION [J].
NUNN, DB ;
FREEMAN, MH ;
HUDGINS, PC .
ANNALS OF SURGERY, 1979, 189 (06) :741-745