Determination of isoprostanes in urine samples from Alzheimer patients using porous graphitic carbon liquid chromatography-tandem mass spectrometry

被引:59
作者
Bohnstedt, KC
Karlberg, B
Wahlund, LO
Jönhagen, ME
Basun, H
Schmidt, S [1 ]
机构
[1] AstraZeneca R&D, DMPK, SE-15185 Sodertalje, Sweden
[2] AstraZeneca R&D, Bioanalyt Chem Dev, SE-15185 Sodertalje, Sweden
[3] Stockholm Univ, Dept Analyt Chem, SE-10691 Stockholm, Sweden
[4] Huddinge Univ Hosp, Dept NEUROTEC, Stockholm, Sweden
[5] AstraZeneca R&D, Clin Sci, SE-15185 Sodertalje, Sweden
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2003年 / 796卷 / 01期
关键词
isoprostanes; porous graphitic carbon;
D O I
10.1016/S1570-0232(03)00600-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
F2-isoprostanes (F2-iPs) comprise four classes of isomers produced non-enzymatically by free radical attack on arachidonic acid, a component of the cell membrane. This paper describes a new method for the quantification of F2-isoprostanes in urine samples from thoroughly diagnosed Alzheimer's disease (AD) patients. The sample pretreatment consisted of liquid extraction of 900 mul urine with diethyl ether, its subsequent evaporation, and finally, reconstitution in 50 mul water. Of this, 20 mul was injected into a HPLC system with a 15 mm x 1 mm porous graphitic carbon column coupled to a triple quadrupole mass spectrometer running in negative electrospray ionization mode. The F2-isoprostanes were separated in 15 ruin using a linear solvent gradient comprising water, methanol, acetonitrile and ammonium hydroxide at a pH of 9.5. The average recovery obtained was approximately 75%. The limit of detection (3S/N) was calculated for iPF2alpha-III to be 0.7 pg injected on column, corresponding to 0.1 nM. The average level of iPF2alpha was 241 +/- 163 pg/mg creatinine in the urine samples from AD patients (average standard deviation). The corresponding control values were 216 +/- 101 pg/mg creatinine, i.e. no statistically significant difference was noticed. No correlation pattern specific to Alzheimer's disease was revealed by principal component analysis of the isoprostane peaks obtained either. The results from this study support earlier findings that levels of peripheral isoprostanes are not increased in patients with Alzheimer's disease. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:11 / 19
页数:9
相关论文
共 29 条
  • [1] Amyloid β-peptide stimulates nitric oxide production in astrocytes through an NFκB-dependent mechanism
    Akama, KT
    Albanese, C
    Pestell, RG
    Van Eldik, LJ
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1998, 95 (10) : 5795 - 5800
  • [2] [Anonymous], 1994, Diagnostic criteria from DSM-IV
  • [3] AGING, ENERGY, AND OXIDATIVE STRESS IN NEURODEGENERATIVE DISEASES
    BEAL, MF
    [J]. ANNALS OF NEUROLOGY, 1995, 38 (03) : 357 - 366
  • [4] Isoprostanes as a biomarker of lipid peroxidation in humans: physiology, pharmacology and clinical implications
    Cracowski, JL
    Durand, T
    Bessard, G
    [J]. TRENDS IN PHARMACOLOGICAL SCIENCES, 2002, 23 (08) : 360 - 366
  • [5] Plasma levels of 8-epiPGF2α, an in vivo marker of oxidative stress, are not affected by aging or Alzheimer's disease
    Feillet-Coudray, C
    Tourtauchaux, R
    Niculescu, M
    Rock, E
    Tauveron, I
    Alexandre-Gouabau, MC
    Rayssiguier, Y
    Jalenques, I
    Mazur, A
    [J]. FREE RADICAL BIOLOGY AND MEDICINE, 1999, 27 (3-4) : 463 - 469
  • [6] MINI-MENTAL STATE - PRACTICAL METHOD FOR GRADING COGNITIVE STATE OF PATIENTS FOR CLINICIAN
    FOLSTEIN, MF
    FOLSTEIN, SE
    MCHUGH, PR
    [J]. JOURNAL OF PSYCHIATRIC RESEARCH, 1975, 12 (03) : 189 - 198
  • [7] POROUS GLASSY-CARBON, A NEW COLUMNS PACKING MATERIAL FOR GAS-CHROMATOGRAPHY AND HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    GILBERT, MT
    KNOX, JH
    KAUR, B
    [J]. CHROMATOGRAPHIA, 1982, 16 : 138 - 148
  • [8] Isoprostanes, novel markers of oxidative injury, help understanding the pathogenesis of neurodegenerative diseases
    Greco, A
    Minghetti, L
    Levi, G
    [J]. NEUROCHEMICAL RESEARCH, 2000, 25 (9-10) : 1357 - 1364
  • [9] STRUCTURE AND PERFORMANCE OF POROUS GRAPHITIC CARBON IN LIQUID-CHROMATOGRAPHY
    KNOX, JH
    KAUR, B
    MILLWARD, GR
    [J]. JOURNAL OF CHROMATOGRAPHY, 1986, 352 : 3 - 25
  • [10] Knox JH, 1997, ADV CHROMATOGR, V37, P73