Toward clinical application of prompt gamma spectroscopy for in vivo monitoring of boron uptake in boron neutron capture therapy

被引:23
作者
af Rosenschöld, PMM
Verbakel, WFAR
Ceberg, CP
Stecher-Rasmussen, F
Persson, BRR
机构
[1] Univ Lund Hosp, Dept Radiat Phys, SE-22185 Lund, Sweden
[2] NRG, NL-1755 ZG Petten, Netherlands
关键词
BNCT; prompt gamma spectroscopy; boron measurements; in vivo dosimetry; gamma-ray telescope;
D O I
10.1118/1.1367281
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In boron neutron capture therapy (BNCT) the absorbed dose to the tumor cells and healthy tissues depends critically on the boron uptake. Pronounced individual variations in the uptake patterns have been observed for two boron compounds currently used in clinical trials. This implies a high uncertainty in the determination of the boron dose component. Ln the present work a technique known as prompt gamma spectroscopy (PGS) is studied that potentially can be used for in vivo and noninvasive boron concentration determination at the time of the treatment. The technique is based upon measurement of gamma rays promptly emitted in the B-10(n, alpha)Li-7 and H-1(n, gamma)D-2 reactions. The aim of this work is to prepare the present setup for clinical application as a monitor of boron uptake in BNCT patients. Therefore, a full calibration and a set of phantom experiments were performed in a clinical setting. Specifically, a nonuniform boron distribution was studied; a skin/dura, a larger blood vessel, and tumor within a head phantom was simulated. The results show that it is possible to determine a homogeneous boron concentration of 5 mug/g within +/-3% (1 standard deviation). In the nonuniform case, this work shows that the boron concentration can be determined through a multistep measurement procedure, however, with a somewhat higher uncertainty (similar to 10%). The present work forms the basis for a subsequent clinical application of the PGS setup aimed at in vivo monitoring of boron uptake. (C) 2001 American Association of Physicists in Medicine.
引用
收藏
页码:787 / 795
页数:9
相关论文
共 17 条
[1]  
Briesmeister JF., 1997, ALAMOS NATL LAB REPO, pLA
[2]   PERFORMANCE OF SULFHYDRYL BORON HYDRIDE IN PATIENTS WITH GRADE-III AND GRADE-IV ASTROCYTOMA - A BASIS FOR BORON NEUTRON-CAPTURE THERAPY [J].
CEBERG, CP ;
PERSSON, A ;
BRUN, A ;
HUISKAMP, R ;
FYHR, AS ;
PERSSON, BRR ;
SALFORD, LG .
JOURNAL OF NEUROSURGERY, 1995, 83 (01) :79-85
[3]   Biodistribution of p-boronophenylalanine in patients with glioblastoma multiforme for use in boron neutron capture therapy [J].
Elowitz, EH ;
Bergland, RM ;
Coderre, JA ;
Joel, DD ;
Chadha, M ;
Chanana, AD .
NEUROSURGERY, 1998, 42 (03) :463-468
[4]   PRESENT STATUS AND PERSPECTIVES OF BORON NEUTRON-CAPTURE THERAPY [J].
GABEL, D .
RADIOTHERAPY AND ONCOLOGY, 1994, 30 (03) :199-205
[5]   PHOTON MASS ATTENUATION AND ENERGY-ABSORPTION COEFFICIENTS FROM 1 KEV TO 20 MEV [J].
HUBBELL, JH .
INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1982, 33 (11) :1269-1290
[6]   MICROANALYSIS SYSTEM OF PPM-ORDER B-10 CONCENTRATIONS IN TISSUE FOR NEUTRON-CAPTURE THERAPY BY PROMPT GAMMA-RAY SPECTROMETRY [J].
KOBAYASHI, T ;
KANDA, K .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 204 (2-3) :525-531
[7]   A noninvasive dose estimation system for clinical BNCT based on PG-SPECT - Conceptual study and fundamental experiments using HPGe and CdTe semiconductor detectors [J].
Kobayashi, T ;
Sakurai, Y ;
Ishikawa, M .
MEDICAL PHYSICS, 2000, 27 (09) :2124-2132
[8]   CEREBRAL BLOOD-FLOW, BLOOD-VOLUME AND OXYGEN UTILIZATION - NORMAL VALUES AND EFFECT OF AGE [J].
LEENDERS, KL ;
PERANI, D ;
LAMMERTSMA, AA ;
HEATHER, JD ;
BUCKINGHAM, P ;
HEALY, MJR ;
GIBBS, JM ;
WISE, RJS ;
HATAZAWA, J ;
HEROLD, S ;
BEANEY, RP ;
BROOKS, DJ ;
SPINKS, T ;
RHODES, C ;
FRACKOWIAK, RSJ ;
JONES, T .
BRAIN, 1990, 113 :27-47
[9]   PHANTOM EXPERIMENT AND CALCULATION FOR INVIVO B-10 ANALYSIS BY PROMPT GAMMA-RAY SPECTROSCOPY [J].
MATSUMOTO, T ;
AOKI, M ;
AIZAWA, O .
PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (03) :329-338
[10]   MONITORING OF BLOOD-B-10 CONCENTRATION FOR BORON NEUTRON-CAPTURE THERAPY USING PROMPT GAMMA-RAY ANALYSIS [J].
RAAIJMAKERS, CPJ ;
KONIJNENBERG, MW ;
DEWIT, L ;
HARITZ, D ;
HUISKAMP, R ;
PHILIPP, K ;
SIEFERT, A ;
STECHERRASMUSSEN, F ;
MIJNHEER, BJ .
ACTA ONCOLOGICA, 1995, 34 (04) :517-523