Background Calcified lesions carry the risk of suboptimal stent expansion. The purpose of this study was to investigate the impact of target lesion calcification on intracoronary ultrasound (ICUS) guided stent expansion after rotational atherectomy. Methods stent expansion was assessed by ICUS in 39 patients with the aid of the proximal stent/proximal reference lumen, the minimal stent/mean reference lumen, and the minimal stent/minor reference lumen ratios as well as the symmetry index. Thirty-nine stent implantations in uncalcified lesions served for comparison. Results Relative stent expansion ranged between 76.3% +/- 6.7% and 98.4% +/- 16.4%. Categorization according to an ICUS-derived are of superficial lesion calcium of <180 degrees (average 102 +/- 74 degrees) or >180 degrees (average 248 +/- 71 degrees) revealed decreased stent symmetry in calcified lesions >180 degrees compared with the control group (P < .05). Despite a trend toward less expansion with increasing calcium load, no significant differences of the lumen area ratios between the study groups was present. Conclusion Rotational atherectomy before ICUS-guided stent implantation enables adequate stent expansion even in significant superficial target lesion calcification.
引用
收藏
页码:93 / 99
页数:7
相关论文
共 32 条
[1]  
AGGUIRE FV, 1993, J AM COLL CARDIOL, V21, P296
[2]   INTRACORONARY 2-DIMENSIONAL ULTRASOUND IMAGING IN THE ASSESSMENT OF PLAQUE MORPHOLOGIC FEATURES AND THE PLANNING OF CORONARY INTERVENTIONS [J].
BAPTISTA, J ;
DIMARIO, C ;
ESCANED, J ;
ARNESE, M ;
OZAKI, Y ;
DEFEYTER, P ;
ROELANDT, JRTC ;
SERRUYS, PW .
AMERICAN HEART JOURNAL, 1995, 129 (01) :177-187
[3]   ROTATIONAL CORONARY ATHERECTOMY AFTER UNSUCCESSFUL CORONARY BALLOON ANGIOPLASTY [J].
BROGAN, WC ;
POPMA, JJ ;
PICHARD, AD ;
SATLER, LF ;
KENT, KM ;
MINTZ, GS ;
LEON, MB .
AMERICAN JOURNAL OF CARDIOLOGY, 1993, 71 (10) :794-798
[4]   INTRACORONARY STENTING WITHOUT ANTICOAGULATION ACCOMPLISHED WITH INTRAVASCULAR ULTRASOUND GUIDANCE [J].
COLOMBO, A ;
HALL, P ;
NAKAMURA, S ;
ALMAGOR, Y ;
MAIELLO, L ;
MARTINI, G ;
GAGLIONE, A ;
GOLDBERG, SL ;
TOBIS, JM .
CIRCULATION, 1995, 91 (06) :1676-1688
[5]  
De Jaegere Peter, 1996, Journal of the American College of Cardiology, V27, p137A
[6]   PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY - REPORT OF COMPLICATIONS FROM THE NATIONAL-HEART-LUNG-AND-BLOOD-INSTITUTE PTCA REGISTRY [J].
DORROS, G ;
COWLEY, MJ ;
SIMPSON, J ;
BENTIVOGLIO, LG ;
BLOCK, PC ;
BOURASSA, M ;
DETRE, K ;
GOSSELIN, AJ ;
GRUNTZIG, AR ;
KELSEY, SF ;
KENT, KM ;
MOCK, MB ;
MULLIN, SM ;
MYLER, RK ;
PASSAMANI, ER ;
STERTZER, SH ;
WILLIAMS, DO .
CIRCULATION, 1983, 67 (04) :723-730
[7]   A RANDOMIZED COMPARISON OF CORONARY-STENT PLACEMENT AND BALLOON ANGIOPLASTY IN THE TREATMENT OF CORONARY-ARTERY DISEASE [J].
FISCHMAN, DL ;
LEON, MB ;
BAIM, DS ;
SCHATZ, RA ;
SAVAGE, MP ;
PENN, I ;
DETRE, K ;
VELTRI, L ;
RICCI, D ;
NOBUYOSHI, M ;
CLEMAN, M ;
HEUSER, R ;
ALMOND, D ;
TEIRSTEIN, PS ;
FISH, RD ;
COLOMBO, A ;
BRINKER, J ;
MOSES, J ;
SHAKNOVICH, A ;
HIRSHFELD, J ;
BAILEY, S ;
ELLIS, S ;
RAKE, R ;
GOLDBERG, S .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) :496-501
[8]   MECHANISMS AND OUTCOMES OF ANGIOPLASTY AND ATHERECTOMY ASSESSED BY INTRAVASCULAR ULTRASOUND IMAGING [J].
FITZGERALD, PJ ;
YOCK, PG .
JOURNAL OF CLINICAL ULTRASOUND, 1993, 21 (09) :579-588
[9]   BENEFIT OF INTRACORONARY ULTRASOUND IN THE DEPLOYMENT OF PALMAZ-SCHATZ STENTS [J].
GOLDBERG, SL ;
COLOMBO, A ;
NAKAMURA, S ;
ALMAGOR, Y ;
MAIELLO, L ;
TOBIS, JM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 24 (04) :996-1003
[10]  
GOLDBERG SL, 1994, J AM COLL CARDIOL, V24, pA290