摘要
We describe extensive tests of Double Gas Electron Multiplier (GEM) and Triple GEM detectors, including large size prototypes for the COMPASS experiment, exposed to high intensity muon, proton and pion beams at the Paul Scherrer Institute and at CERN. The measurements aim at detecting problems possibly appearing under these harsh operating conditions, the main concern being the occurrence of discharges induced by beam particles. Results for the dependence of the probability for induced discharges on the experimental environment are presented and discussed, Implications for the application of GEM detectors in experiments at high luminosity colliders are illustrated. (C), 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:548 / 561
页数:14
相关论文
共 16 条
[1]   Charge amplification and transfer processes in the gas electron multiplier [J].
Bachmann, S ;
Bressan, A ;
Ropelewski, L ;
Sauli, F ;
Sharma, A ;
Mörmann, D .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 438 (2-3) :376-408
[2]  
BACHMANN S, 1999, UNPUB NUCL INSTR MET
[3]  
BACHMANN S, UNPUB NUCL INSTR MET
[4]  
BAUM G, 1996, 9614 CERNSPLSC
[5]   Further developments and beam tests of the gas electron multiplier (GEM) [J].
Benlloch, J ;
Bressan, A ;
Capeáns, M ;
Gruwé, M ;
Hoch, M ;
Labbé, JC ;
Placci, A ;
Ropelewski, L ;
Sauli, F .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 419 (2-3) :410-417
[6]   Beam tests of the gas electron multiplier [J].
Bressan, A ;
Labbé, JC ;
Pagano, P ;
Ropelewski, L ;
Sauli, F .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 425 (1-2) :262-276
[7]   Two-dimensional readout of GEM detectors [J].
Bressan, A ;
De Oliveira, R ;
Gandi, A ;
Labbé, JC ;
Ropelewski, L ;
Sauli, F ;
Mörmann, D ;
Müller, T ;
Simonis, HJ .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 425 (1-2) :254-261
[8]   FEEDBACK AND BREAKDOWN IN PARALLEL-PLATE CHAMBERS [J].
FONTE, P ;
PESKOV, V ;
SAULI, F .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 305 (01) :91-110
[9]   A model of breakdown in parallel-plate detectors [J].
Fonte, P .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (03) :2135-2140
[10]  
JONES LL, 1995, PREMUX128 SPECIFICAT