Laboratory and on-road evaluations of cabin air filters using number and surface area concentration monitors

被引:52
作者
Qi, Chaolong [1 ]
Stanley, Nick [1 ]
Pui, David Y. H. [1 ]
Kuehn, Thomas H. [1 ]
机构
[1] Univ Minnesota, Dept Mech Engn, Minneapolis, MN 55455 USA
关键词
D O I
10.1021/es703216c
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
An automotive cabin air filter's effectiveness for removing airborne particles was determined both in a laboratory wind tunnel and in vehicle on-road tests. The most penetrating particle size for the test filter was similar to 350 nm, where the filtration efficiency was 22.9 and 17.4% at medium and high fan speeds, respectively. The filtration efficiency increased for smaller particles and was 43.9% for 100 nm and 72.0% for 20 nm particles at a medium fan speed. We determined the reduction in passenger exposure to particles while driving in freeway traffic caused by a vehicle ventilation system with. a cabin air filter installed. Both particle number and surface area concentration measurements were made inside the cabin and in the surrounding air. At medium fan speed, the number and surface area concentration-based exposure reductions were 65.6 +/- 6.0% and 60.6 +/- 9.4%, respectively. To distinguish the exposure reduction contribution from the filter alone and the remainder of the ventilation system, we also per formed tests with and without the filter in place using the surface area monitors. The ventilation system operating in the recirculation mode with the cabin air filter installed provided the maximum protection, reducing the cabin particle concentration exponentially over time and usually taking only 3 min to reach 10 mu m(2)/cm(3) (a typical office air condition) under medium fan speed.
引用
收藏
页码:4128 / 4132
页数:5
相关论文
共 25 条
[1]  
*AM SOC HEAT REFR, 1999, 522 ASHRAE
[2]  
ASBACH C, 2007, COMP ULTRAFINE PARTI
[3]   Size-dependent proinflammatory effects of ultrafine polystyrene particles: A role for surface area and oxidative stress in the enhanced activity of ultrafines [J].
Brown, DM ;
Wilson, MR ;
MacNee, W ;
Stone, V ;
Donaldson, K .
TOXICOLOGY AND APPLIED PHARMACOLOGY, 2001, 175 (03) :191-199
[4]  
Capaldo K., 2001, LIFETIMES ULTRAFINE
[5]   Ultrafine (nanometre) particle mediated lung injury [J].
Donaldson, K ;
Li, XY ;
MacNee, W .
JOURNAL OF AEROSOL SCIENCE, 1998, 29 (5-6) :553-560
[6]   The effect of different ventilation modes on in-vehicle carbon monoxide exposure [J].
Esber, L. Abi ;
El-Fadel, M. ;
Nuwayhid, I. ;
Saliba, N. .
ATMOSPHERIC ENVIRONMENT, 2007, 41 (17) :3644-3657
[7]   Rationale and principle of an instrument measuring lung deposited nanoparticle surface area [J].
Fissan, H. ;
Neumann, S. ;
Trampe, A. ;
Pui, D. Y. H. ;
Shin, W. G. .
JOURNAL OF NANOPARTICLE RESEARCH, 2007, 9 (01) :53-59
[8]   Measurements and predictors of on-road ultrafine particle concentrations and associated pollutants in Los Angeles [J].
Fruin, S. ;
Westerdahl, D. ;
Sax, T. ;
Sioutas, C. ;
Fine, P. M. .
ATMOSPHERIC ENVIRONMENT, 2008, 42 (02) :207-219
[9]  
Hinds W.C., 1999, Aerosol technology: Properties, behavior, and measurement of airborne particles, V2nd ed., DOI [DOI 10.1016/0021-8502(83)90049-6, 10.1016/0021-8502(83)90049-6]
[10]  
ISO, 2001, ROAD VEH AIR FILT PA