Genetic algorithm-based wavelength selection for the near-infrared determination of glucose in biological matrixes: Initialization strategies and effects of spectral resolution

被引:79
作者
Ding, Q
Small, GW [1 ]
Arnold, MA
机构
[1] Ohio Univ, Dept Biochem & Chem, Ctr Intelligent Chem Instrumentat, Athens, OH 45701 USA
[2] Univ Iowa, Dept Chem, Iowa Adv Technol Labs, Iowa City, IA 52242 USA
关键词
D O I
10.1021/ac980451q
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An improved genetic algorithm (GA)-based wavelength selection procedure is developed to optimize both the near-infrared wavelengths used and the number of latent variables employed in building partial least-squares (PLS) calibration models. This GA-based wavelength selection algorithm is applied to the determination of glucose in two different biological matrixes. With random selection of a small number of initial wavelengths, a dramatic reduction in the number of wavelengths required for building the PLS calibration models is observed. The fitness function used to guide the GA, the method of recombination used, and the effect of spectral resolution on the wavelength selection are also studied. In the resolution study, the original data with a point spacing of 2 cm(-1) are deresolved to 4-, 8-, and 16-cm(-1) point spacings by truncating the collected interferograms before applying the Fourier processing step. The use of lower resolution spectra is found to reduce further the number of final wavelengths selected by the GA, and the performance of the optimal calibration models obtained with the original spectra is maintained with the lower resolution spectra of both 4- and 8-cm(-1) point spacing. Degradation in performance is observed with the spectra computed with a point spacing of 16-cm(-1), however.
引用
收藏
页码:4472 / 4479
页数:8
相关论文
共 29 条
[1]   DETERMINATION OF PHYSIOLOGICAL LEVELS OF GLUCOSE IN AN AQUEOUS MATRIX WITH DIGITALLY FILTERED FOURIER-TRANSFORM NEAR-INFRARED SPECTRA [J].
ARNOLD, MA ;
SMALL, GW .
ANALYTICAL CHEMISTRY, 1990, 62 (14) :1457-1464
[2]   Genetic algorithm-based method for selecting wavelengths and model size for use with partial least-squares regression: Application to near-infrared spectroscopy [J].
Bangalore, AS ;
Shaffer, RE ;
Small, GW ;
Arnold, MA .
ANALYTICAL CHEMISTRY, 1996, 68 (23) :4200-4212
[3]   MATRIX REPRESENTATIONS AND CRITERIA FOR SELECTING ANALYTICAL WAVELENGTHS FOR MULTICOMPONENT SPECTROSCOPIC ANALYSIS [J].
BROWN, CW ;
LYNCH, PF ;
OBREMSKI, RJ ;
LAVERY, DS .
ANALYTICAL CHEMISTRY, 1982, 54 (09) :1472-1479
[4]   WAVELENGTH SELECTION IN MULTICOMPONENT NEAR-INFRARED CALIBRATION [J].
BROWN, PJ .
JOURNAL OF CHEMOMETRICS, 1992, 6 (03) :151-161
[6]  
BURMEISTER JJ, 1995, ANAL LETT, V28, P581
[7]   Wavelength selection for the determination of glucose in human serum by near-infrared spectroscopy [J].
Ding, Q ;
Small, GW .
FOURIER TRANSFORM SPECTROSCOPY, 1998, (430) :264-267
[8]   PARTIAL LEAST-SQUARES METHODS FOR SPECTRAL ANALYSES .1. RELATION TO OTHER QUANTITATIVE CALIBRATION METHODS AND THE EXTRACTION OF QUALITATIVE INFORMATION [J].
HAALAND, DM ;
THOMAS, EV .
ANALYTICAL CHEMISTRY, 1988, 60 (11) :1193-1202
[9]   TEMPERATURE-INSENSITIVE NEAR-INFRARED SPECTROSCOPIC MEASUREMENT OF GLUCOSE IN AQUEOUS-SOLUTIONS [J].
HAZEN, KH ;
ARNOLD, MA ;
SMALL, GW .
APPLIED SPECTROSCOPY, 1994, 48 (04) :477-483
[10]   FURTHER INVESTIGATION ON A COMPARATIVE-STUDY OF SIMULATED ANNEALING AND GENETIC ALGORITHM FOR WAVELENGTH SELECTION [J].
HORCHNER, U ;
KALIVAS, JH .
ANALYTICA CHIMICA ACTA, 1995, 311 (01) :1-13