The transient extension (TEx) chamber was developed to provide a simple means of lengthening an electrothermal vaporizer (ETV) signal for the purpose of obtaining a full mass scan from a single ETV firing with inductively coupled plasma mass spectrometry (ICPMS) detection. The TEx chamber was used for quantitative analysis of natural water (NIST SRM 1640). Quantitative analysis was done for Co, Be, Pb, Sb and Cd. Detection limits for the five elements tested with the TEx chamber were in the 1-10 mug L-1 range when monitoring 256 masses during a single ETV firing. In general, there was no significant change in the analyte signal using palladium, sodium chloride or magnesium nitrate modifiers when comparing results with and without the TEx chamber.
引用
收藏
页码:878 / 883
页数:6
相关论文
共 23 条
[1]   EVALUATION OF A MODIFIED COMMERCIAL GRAPHITE-FURNACE FOR REDUCTION OF ISOBARIC INTERFERENCES IN ARGON INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
CAREY, JM ;
EVANS, EH ;
CARUSO, JA ;
SHEN, WL .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1991, 46 (13) :1711-1721
[2]  
CRAIN JS, 1988, SPECTROCHIM ACTA B, V43, P1355
[3]   STUDY OF SOLIDS DEPOSITION ON INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY SAMPLERS AND SKIMMERS [J].
DOUGLAS, DJ ;
KERR, LA .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1988, 3 (06) :749-752
[4]   THE ROLE OF CHEMICAL MODIFIERS IN ANALYTE TRANSPORT LOSS INTERFERENCES WITH ELECTROTHERMAL VAPORIZATION ICP-MASS SPECTROMETRY [J].
EDIGER, RD ;
BERES, SA .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1992, 47 (07) :907-922
[5]   Influence of sample matrix components on the selection of calibration strategies in electrothermal vaporization inductively coupled plasma mass spectrometry [J].
Fonseca, RW ;
MillerIhli, NJ .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1996, 51 (13) :1591-1599
[6]   Effect of concomitant elements on the distribution of ions in inductively coupled plasma-mass spectroscopy. Part 1. Elemental ions [J].
Fraser, MM ;
Beauchemin, D .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2000, 55 (11) :1705-1731
[7]   Analyte transport efficiency with electrothermal vaporization inductively coupled plasma mass spectrometry [J].
Grégoire, DC ;
Sturgeon, RE .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1999, 54 (05) :773-786
[8]   BACKGROUND SPECTRAL FEATURES IN ELECTROTHERMAL VAPORIZATION INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY - MOLECULAR-IONS RESULTING FROM THE USE OF CHEMICAL MODIFIERS [J].
GREGOIRE, DC ;
STURGEON, RE .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1993, 48 (11) :1347-1364
[9]  
Gregoire DC, 1997, SPECTROCHIM ACTA B, V52, P75
[10]   An investigation of different modifiers in electrothermal vaporization inductively coupled plasma mass spectrometry (ETV-ICP-MS) [J].
Grunke, K ;
Stark, HJ ;
Wennrich, R ;
Ortner, HM ;
Broekaert, JAC .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 359 (4-5) :465-468