Blood pressure in the neonate: Three non-invasive oscillometric pressure monitors compared with invasively measured blood pressure

被引:56
作者
Dannevig, I
Dale, HC
Liestol, K
Lindemann, R [1 ]
机构
[1] Ullevaal Univ Hosp, Dept Paediat, Neonatal Intens Care Unit, NO-0407 Oslo, Norway
[2] Univ Oslo, Dept Informat, N-0316 Oslo, Norway
关键词
blood pressure; invasive; neonate; non-invasive; preterm;
D O I
10.1080/08035250410023629
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Aim: To compare blood pressure in neonates obtained from three different oscillometer blood pressure monitors (Dinamap(TM), Criticare(TM), Hewlett-Packard(TM)) with arterial blood pressure (Hewlett-Packard(TM) invasive unit). Study design: A total of 32 randomized, non-invasive blood pressure series, each consisting of three measurements from each monitor, were obtained from 20 neonates (birthweight 531-4660 g). Each measurement was compared with the invasive pressure. Results: Two factors appear to have a systematic effect on the difference between oscillometric and invasive pressure (the measurement deviance): the size of the infant, e.g., the arm circumference, and the monitor system. For small infants, the non-invasively measured value tends to be too high. The deviance is partly reversed for larger infants (dependency on size significant for mean and diastolic pressure, p<0.001). The difference between monitor systems is clearly significant (p<0.001). Hewlett-Packard(TM) gives the lowest pressure values for all pressures. Thus, Criticare(TM) and Dinamap(TM) tended to show values too high in the smallest infants, while Hewlett-Packard(TM) tended to give values too low in larger infants. Birthweight, present weight and arm circumference affected measurement deviance approximately equally strongly, while factors such as the infant's sex, need of breath support and umbilical or radial arterial line were nonsignificant. Conclusions: Blood pressure should preferably be measured invasively in severely ill neonates and preterm infants, being aware of pitfalls with measurements using different oscillometer monitors and the size/arm circumference of the infant.
引用
收藏
页码:191 / 196
页数:6
相关论文
共 28 条
[1]   BLOOD-PRESSURE MONITORING IN NEONATES - COMPARISON OF UMBILICAL AND PERIPHERAL ARTERY CATHETER MEASUREMENTS [J].
BUTT, WW ;
WHYTE, H .
JOURNAL OF PEDIATRICS, 1984, 105 (04) :630-632
[2]   Discrepancies between direct and indirect blood pressure measurements using various recommendations for arm cuff selection [J].
Clark, JA ;
Lieh-Lai, MW ;
Sarnaik, A ;
Mattoo, TK .
PEDIATRICS, 2002, 110 (05) :920-923
[3]   NON-INVASIVE DETERMINATION OF SYSTOLIC, DIASTOLIC AND END-SYSTOLIC BLOOD-PRESSURE IN NEONATES, INFANTS AND YOUNG-CHILDREN - COMPARISON WITH CENTRAL AORTIC PRESSURE MEASUREMENTS [J].
COLAN, SD ;
FUJII, A ;
BOROW, KM ;
MACPHERSON, D ;
SANDERS, SP .
AMERICAN JOURNAL OF CARDIOLOGY, 1983, 52 (07) :867-870
[4]   DINAMAP FAILS TO DETECT HYPOTENSION IN VERY-LOW-BIRTH-WEIGHT INFANTS [J].
DIPROSE, GK ;
EVANS, DH ;
ARCHER, LNJ ;
LEVENE, MI .
ARCHIVES OF DISEASE IN CHILDHOOD, 1986, 61 (08) :771-773
[5]   NONINVASIVE BLOOD-PRESSURE MONITORING IN PRETERM INFANTS RECEIVING INTENSIVE-CARE [J].
EMERY, EF ;
GREENOUGH, A .
EUROPEAN JOURNAL OF PEDIATRICS, 1992, 151 (02) :136-139
[6]   ASSESSMENT OF NONINVASIVE TECHNIQUES FOR MEASURING BLOOD-PRESSURE IN PRETERM INFANTS OF BIRTH-WEIGHT LESS-THAN OR EQUAL TO 750 GRAMS [J].
EMERY, EF ;
GREENOUGH, A .
EARLY HUMAN DEVELOPMENT, 1993, 33 (03) :217-222
[7]  
FRIESEN RH, 1981, ANESTH ANALG, V60, P742
[8]   IS THE BLOOD-PRESSURE THE SAME IN BOTH ARMS [J].
GOULD, BA ;
HORNUNG, RS ;
KIESO, HA ;
ALTMAN, DG ;
RAFTERY, EB .
CLINICAL CARDIOLOGY, 1985, 8 (08) :423-426
[9]   RANDOMIZED TRIAL COMPARING DOPAMINE AND DOBUTAMINE IN PRETERM INFANTS [J].
GREENOUGH, A ;
EMERY, EF .
EUROPEAN JOURNAL OF PEDIATRICS, 1993, 152 (11) :925-927
[10]  
Hegyi T, 1996, PEDIATRICS, V97, P336