Effect of ambient temperature on the performance of micro gas turbine with cogeneration system in cold region

被引:61
作者
Basrawi, Firdaus [1 ]
Yamada, Takanobu [1 ]
Nakanishi, Kimio [1 ]
Naing, Soe [1 ]
机构
[1] Kitami Inst Technol, Dept Mech Engn, Kitami, Hokkaido 0908507, Japan
关键词
Micro gas turbine; Cogeneration system; Inlet air temperature; Energy; Efficiency; Biomass; Biogas;
D O I
10.1016/j.applthermaleng.2010.10.033
中图分类号
O414.1 [热力学];
学科分类号
摘要
A small-scale prime mover especially micro gas turbine is a key factor in order to widespread the utilization of biogas. It is well known that a performance of large-scale gas turbine is greatly affected by its inlet air temperature. However, the effect of the inlet air temperature on the performance of small-scale gas turbine (micro gas turbine) is not widely reported. The purpose of the present study is to investigate the effect of the inlet air temperature on the performance of a micro gas turbine (MGT) with cogeneration system (CGS) arrangement. An analysis model of the MGT-CGS was set up on the basis of experimental results obtained in a previous study and a manufacturer standard data, and it was analysed under a various ambient temperature condition in a cold region. The results show that when ambient temperature increased, electrical efficiency net, of the MGT decreased but exhaust heat recovery eta(ehr) increased. It was also found that when ambient temperature increased, exhaust heat to mass flow rate Q(exe)/m(e) and exhaust heat recovery to mass flow rate Q(ehr)/m(e) me increased, with maximum ratios of 259 kJ/kg and 200 kJ/kg, respectively were found in summer peak. Furthermore, it was also found that the exhaust heat to power ratio eta(ele) had a similar characteristic with exhaust heat recovery to power ratio Q(ehr)/m(e). Q(exe)/m(e) and Q(ehr)/m(e) increased with the increase of ambient temperature. Moreover, although different values of total energy efficiency, fuel energy saving and CO2 reduction for every temperature condition were found comparing with a two conventional system that were considered, the MGT CGS could annually reduce 30,000-80,000 m(3)/y of fuel consumption and 35-94 t-CO2/y of CO2 emissions. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1058 / 1067
页数:10
相关论文
共 35 条
[1]   Augmentation of gas turbine performance using air coolers [J].
Alhazmy, MM ;
Najjar, YSH .
APPLIED THERMAL ENGINEERING, 2004, 24 (2-3) :415-429
[2]   Influence of ambient temperature on combined-cycle power-plant performance [J].
Arrieta, FRP ;
Lora, EES .
APPLIED ENERGY, 2005, 80 (03) :261-272
[3]  
*AV CONS INC MIDW, 2005, COMB HEAT POW CHP RE, P11
[4]   Gas-turbine performance improvements [J].
Badran, OO .
APPLIED ENERGY, 1999, 64 (1-4) :263-273
[5]   Performance improvements of the intercooled reheat recuperated gas-turbine cycle using absorption inlet-cooling and evaporative after-cooling [J].
Bassily, AM .
APPLIED ENERGY, 2004, 77 (03) :249-272
[6]   Gas turbine performance increase using an air cooler with a phase change energy storage [J].
Bedecarrats, Jean-Pierre ;
Strub, Francoise .
APPLIED THERMAL ENGINEERING, 2009, 29 (5-6) :1166-1172
[7]   Raising cycle efficiency by intercooling in air-cooled gas turbines [J].
Caniere, H. ;
Willockx, A. ;
Dick, E. ;
De Paepe, M. .
APPLIED THERMAL ENGINEERING, 2006, 26 (16) :1780-1787
[8]  
*CAPST TURB CORP, GLOB CAS STUD
[9]   Economics of biomass energy utilization in combustion and gasification plants: effects of logistic variables [J].
Caputo, AC ;
Palumbo, M ;
Pelagagge, PM ;
Scacchia, F .
BIOMASS & BIOENERGY, 2005, 28 (01) :35-51
[10]   Integration of absorption cooling systems into micro gas turbine trigeneration systems using biogas: Case study of a sewage treatment plant [J].
Caries Bruno, Joan ;
Ortega-Lopez, Victor ;
Coronas, Alberto .
APPLIED ENERGY, 2009, 86 (06) :837-847