A novel system for intracoronary beta-irradiation: Description and dosimetric results

被引:25
作者
Popowski, Y
Verin, V
Schwager, M
Nouet, P
Papirov, I
Rouzaud, M
Urban, P
Landis, JR
Rutishauser, W
Kurtz, JM
机构
[1] UNIV HOSP GENEVA,DIV RADIAT ONCOL,GENEVA,SWITZERLAND
[2] UNIV HOSP GENEVA,CTR CARDIOL,GENEVA,SWITZERLAND
[3] SCHNEIDER EUROPE AG,BULACH,SWITZERLAND
[4] PENN STATE UNIV HOSP,CTR BIOSTAT & EPIDEMIOL,HERSHEY,PA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1996年 / 36卷 / 04期
关键词
percutaneous transluminal coronary angioplasty; restenosis; intravascular brachytherapy;
D O I
10.1016/S0360-3016(96)00409-9
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: A dosimetric evaluation of a new device dedicated to intravascular irradiation, associating a beta source and a centering device, was carried out before initiation of a clinical pilot study. Methods and Materials: A 29-mm-long Y-90 coil, coated with titanium and fixed to the end of a thrust wire, was introduced into the inner lumen of purpose-built centering balloons of different diameters (2.5, 3, 3.5, and 4 mm). Dose homogeneity was evaluated by studying both axial and circumferential dose variations, based on readings from thermoluminescent dosimeters (TLDs) placed on the balloon surface. Axial homogeneity was determined by comparing the readout values of dosimeters located on peripheral balloon segments with those located on segments adjacent to the midpoint of the source. The centering ability of the device was studied by comparing measurements on opposing surfaces of the balloon. The dose attenuation by water and contrast medium was evaluated and compared with that in air. The balloon contamination was studied using a contamination counter. The total Y-90 coil activity was measured by liquid scintillation to relate activity to surface dose. Results: Activity-surface dose correlation showed that for a linear coil activity of 1 mCi/mm, the mean dose rate at the surface of a 2.5-mm balloon filled with contrast medium was 8.29 Gy/min. The doses at the surface of larger balloons (3, 3.5, and 4 mm) filled with contrast were 78%, 59%, and 47%, respectively, of the dose measured at the surface of the 2.5-mm balloon. The coefficient of variation (CV) in surface dose for 2.5-, 3-, 3.5-, and 4-mm centering devices filled with contrast medium were 9%, 8%, 9%, and 12%, respectively. There was no statistically significant difference between readouts from central and peripheral balloon segments or among rows of dosimeters facing each other. For a 2.5-mm balloon, compared-with air the dose attenuation by water and contrast medium was similar (0.70 and 0.69, respectively), but a significant difference was seen between the readouts of water- and contrast-filled balloons when the diameter was larger than 3 mm (p < 0.001). No contamination was found in the balloon shaft after source retrieval. Conclusion: The dosimetric tests showed very good surface dose homogeneity, demonstrating satisfactory centering of the source within the centering balloons. The achievable dose rates will permit intravascular irradiation within a short time interval. The absence of residual balloon contamination after source retrieval meets the requirements for a sealed source used in a clinical setting. Copyright (C) 1996 Elsevier Science Inc.
引用
收藏
页码:923 / 931
页数:9
相关论文
共 28 条
[1]   RETROVIRAL SUICIDE VECTOR DOES NOT INHIBIT NEOINTIMAL GROWTH IN A PORCINE CORONARY MODEL OF RESTENOSIS [J].
BARBEE, RW ;
STAPLETON, DD ;
MADRAS, DE ;
RE, RN ;
MURGO, JP ;
DAVENPORT, WD ;
GIARDINA, J ;
COOK, JL .
BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 1995, 207 (01) :89-98
[2]  
BOTTCHER HD, 1994, INT J RADIAT ONCOL, V29, P183
[3]  
CONDADO JA, 1996, DISCOVERIES RAD REST, P105
[4]   LOW-DOSE, BETA-PARTICLE EMISSION FROM STENT WIRE RESULTS IN COMPLETE, LOCALIZED INHIBITION OF SMOOTH-MUSCLE CELL-PROLIFERATION [J].
FISCHELL, TA ;
KHARMA, BK ;
FISCHELL, DR ;
LOGES, PG ;
COFFEY, CW ;
DUGGAN, DM ;
NAFTILAN, AJ .
CIRCULATION, 1994, 90 (06) :2956-2963
[5]  
FISHELL TA, 1995, DISCOVERIES RAD REST, P65
[6]   RESPONSE OF AORTA AND BRANCH ARTERIES TO EXPERIMENTAL INTRAOPERATIVE IRRADIATION [J].
GILLETTE, EL ;
POWERS, BE ;
MCCHESNEY, SL ;
PARK, RD ;
WITHROW, SJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1989, 17 (06) :1247-1255
[7]   IN-VIVO SUPPRESSION OF INJURY-INDUCED VASCULAR SMOOTH-MUSCLE CELL ACCUMULATION USING ADENOVIRUS-MEDIATED TRANSFER OF THE HERPES-SIMPLEX VIRUS THYMIDINE KINASE GENE [J].
GUZMAN, RJ ;
HIRSCHOWITZ, EA ;
BRODY, SL ;
CRYSTAL, RG ;
EPSTEIN, SE ;
FINKEL, T .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1994, 91 (22) :10732-10736
[8]   IRRADIATION INCREASES EXPRESSION OF GM-CSF IN HUMAN FIBROBLASTS BY TRANSCRIPTIONAL AND POSTTRANSCRIPTIONAL REGULATION [J].
HACHIYA, M ;
SUZUKI, G ;
KOEFFLER, HP ;
AKASHI, M .
EXPERIMENTAL CELL RESEARCH, 1994, 214 (01) :343-350
[9]   LOW-DOSE RADIOACTIVE ENDOVASCULAR STENTS PREVENT SMOOTH-MUSCLE CELL-PROLIFERATION AND NEOINTIMAL HYPERPLASIA IN RABBITS [J].
HEHRLEIN, C ;
GOLLAN, C ;
DONGES, K ;
METZ, J ;
RIESSEN, R ;
FEHSENFELD, P ;
VONHODENBERG, E ;
KUBLER, W .
CIRCULATION, 1995, 92 (06) :1570-1575
[10]   RADIOASSAY BY AN EFFICIENCY TRACING TECHNIQUE USING A LIQUID SCINTILLATION-COUNTER [J].
ISHIKAWA, H ;
TAKIUE, M ;
ABURAI, T .
INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1984, 35 (06) :463-466