Poly(dimethylsiloxane) (PDMS) capillary electrophoresis (CE) microchips were modified by a dynamic coating method that provided stable electroosmotic flow (EOF) with respect to pH. The separation channel was coated with a polymer bilayer consisting of a cationic layer of Polybrene (PB) and an anionic layer of dextran sulfate (DS). According to the difference in charge, PB- and PB/ DS-coated channels supported EOF in different directions; however, both methods of channel coating exhibited a pH-independent EOF in the pH range of 5-10 due to chemical control of the effective xi -potential. The endurance of the PB-coated layer was determined to be 50 runs at pH 3.0, while PB/DS-coated chips had a stable EOF for more than 100 runs. The effect of substrate composition and chip-sealing methodology was also evaluated. All tested chips showed the same EOF on the PB/DS-coated channels, as compared to uncoated chips, which varied significantly. No significant variation for separation and electrochemical detection of dopamine and hydroquinone between coated and uncoated channels was observed.
引用
收藏
页码:5939 / 5944
页数:6
相关论文
共 36 条
[1]   Treatments of fused-silica capillaries and their influence on the electrophoretic characteristics of these columns before and after coating [J].
Cifuentes, A ;
Canalejas, P ;
Ortega, A ;
Díez-Masa, JC .
JOURNAL OF CHROMATOGRAPHY A, 1998, 823 (1-2) :561-571
[2]   Rapid prototyping of microfluidic systems in poly(dimethylsiloxane) [J].
Duffy, DC ;
McDonald, JC ;
Schueller, OJA ;
Whitesides, GM .
ANALYTICAL CHEMISTRY, 1998, 70 (23) :4974-4984
[3]   Integrated chip-based capillary electrophoresis [J].
Effenhauser, CS ;
Bruin, GJM ;
Paulus, A .
ELECTROPHORESIS, 1997, 18 (12-13) :2203-2213
[4]   Nanoflow solvent gradient delivery from a microfabricated device for protein identifications by electrospray ionization mass spectrometry [J].
Figeys, D ;
Aebersold, R .
ANALYTICAL CHEMISTRY, 1998, 70 (18) :3721-3727
[5]   Characterization of electrochemical array detection for continuous channel electrophoretic separations in micrometer and submicrometer channels [J].
Gavin, PF ;
Ewing, AG .
ANALYTICAL CHEMISTRY, 1997, 69 (18) :3838-3845
[6]   CAPILLARY ELECTROPHORESIS AND SAMPLE INJECTION SYSTEMS INTEGRATED ON A PLANAR GLASS CHIP [J].
HARRISON, DJ ;
MANZ, A ;
FAN, ZH ;
LUDI, H ;
WIDMER, HM .
ANALYTICAL CHEMISTRY, 1992, 64 (17) :1926-1932
[7]   ELECTROOSMOTIC FLOW-CONTROL AND SURFACE CONDUCTANCE IN CAPILLARY ZONE ELECTROPHORESIS [J].
HAYES, MA ;
KHETERPAL, I ;
EWING, AG .
ANALYTICAL CHEMISTRY, 1993, 65 (15) :2010-2013
[8]   CURRENT-MONITORING METHOD FOR MEASURING THE ELECTROOSMOTIC FLOW-RATE IN CAPILLARY ZONE ELECTROPHORESIS [J].
HUANG, XH ;
GORDON, MJ ;
ZARE, RN .
ANALYTICAL CHEMISTRY, 1988, 60 (17) :1837-1838
[9]   MICROCHIP ELECTROPHORESIS WITH SAMPLE STACKING [J].
JACOBSON, SC ;
RAMSEY, JM .
ELECTROPHORESIS, 1995, 16 (04) :481-486
[10]   FUSED QUARTZ SUBSTRATES FOR MICROCHIP ELECTROPHORESIS [J].
JACOBSON, SC ;
MOORE, AW ;
RAMSEY, JM .
ANALYTICAL CHEMISTRY, 1995, 67 (13) :2059-2063