Capacity control for refrigeration and air-conditioning systems: A comparative study

被引:22
作者
Yaqub, M [1 ]
Zubair, SM [1 ]
机构
[1] King Fahd Univ Petr & Minerals, Dept Mech Engn, Dhahran 31261, Saudi Arabia
来源
JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME | 2001年 / 123卷 / 01期
关键词
D O I
10.1115/1.1349117
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The capacity control of a vapor-compression refrigeration system is investigated for three different capacity control schemes. In a hot-gas by-pass control scheme, the refrigerant is by-passed from the compressor and injected back into the suction line to decrease the cooling capacity, whereas in cylinder-unloading scheme, one or more cylinders are unloaded to decrease the refrigerant mass flow rate in the system, which decreases the cooling capacity, However, in suction gas throttling, the suction gas throttled at the inlet of the compressor, decreases the refrigerant mass flow rate, and hence a corresponding decrease in the system capacity. These schemes are investigated for HFC-134a by considering finite size of the components that are used in the refrigeration systems. The models consider the finite-temperature difference in the heat exchangers, thus allowing the variations in the condenser and evaporator temperatures with respect To capacity and external fluid inlet temperatures. A comparitive study is performed among these schemes in terms of the system coefficient of performance (COP), the operating temperatures, and percentage of refrigerant mass fraction as a function of the percentage of full-load system capacity.
引用
收藏
页码:92 / 99
页数:8
相关论文
共 10 条
[1]  
[Anonymous], ASHRAE T
[2]  
[Anonymous], AIR CONDITIONING HEA
[3]   Experimental study of the fundamental properties of reciprocating chillers and their relation to thermodynamic modeling and chiller design [J].
Chua, HT ;
Ng, KC ;
Gordon, JM .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1996, 39 (11) :2195-2204
[4]   Design and performance evaluation of reciprocating refrigeration systems [J].
Khan, JUR ;
Zubair, SM .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1999, 22 (03) :235-243
[5]   THERMODYNAMIC ANALYSES OF THE CFC-12 AND HFC-134A REFRIGERATION CYCLES [J].
KHAN, SH ;
ZUBAIR, SM .
ENERGY, 1993, 18 (07) :717-726
[6]   DESIGN CONSIDERATIONS FOR REFRIGERATION CYCLES [J].
KLEIN, SA .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1992, 15 (03) :181-185
[7]   2ND-LAW-BASED THERMODYNAMIC ANALYSIS OF HOT-GAS, BYPASS, CAPACITY-CONTROL SCHEMES FOR REFRIGERATION AND AIR-CONDITIONING SYSTEMS [J].
YAQUB, M ;
ZUBAIR, SM ;
KHAN, SH .
ENERGY, 1995, 20 (06) :483-493
[8]   Thermodynamic analysis of capacity-control schemes for refrigeration and air-conditioning systems [J].
Yaqub, M ;
Zubair, SM .
ENERGY, 1996, 21 (06) :463-472
[9]  
HEATING PIPING AIR C
[10]  
ASHRAE J