Transient transcapillary exchange of water driven by osmotic forces in the heart

被引:34
作者
Kellen, MR [1 ]
Bassingthwaighte, JB [1 ]
机构
[1] Univ Washington, Dept Bioengn, Seattle, WA 98195 USA
来源
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY | 2003年 / 285卷 / 03期
关键词
capillary permeability; reflection coefficient; transport modeling; microcirculation; isolated rabbit heart; porous transport;
D O I
10.1152/ajpheart.00587.2002
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Osmotic transient responses in organ weight after changes in perfusate osmolarity have implied steric hindrance to small-molecule transcapillary exchange, but tracer methods do not. We obtained osmotic weight transient data in isolated, Ringer-perfused rabbit hearts with NaCl, urea, glucose, sucrose, raffinose, inulin, and albumin and analyzed the data with a new anatomically and physicochemically based model accounting for 1) transendothelial water flux, 2) two sizes of porous passages across the capillary wall, 3) axial intracapillary concentration gradients, and 4) water fluxes between myocytes and interstitium. During steady-state conditions similar to28% of the transcapillary water flux going to form lymph was through the endothelial cell membranes [ capillary hydraulic conductivity (L-p) = 1.8 +/- 0.6 x 10(-8) cm . s(-1) . mmHg(-1)], presumably mainly through aquaporin channels. The interendothelial clefts (with L-p = 4.4 +/- 1.3 x 10(-8) cm . s(-1) . mmHg(-1)) account for 67% of the water flux; clefts are so wide ( equivalent pore radius was 7 +/- 0.2 nm, covering similar to0.02% of the capillary surface area) that there is no apparent hindrance for molecules as large as raffinose. Infrequent large pores account for the remaining 5% of the flux. During osmotic transients due to 30 mM increases in concentrations of small solutes, the transendothelial water flux was in the opposite direction and almost 800 times as large and was entirely transendothelial because no solute gradient forms across the pores. During albumin transients, gradients persisted for long times because albumin does not permeate small pores; the water fluxes per milliosmolar osmolarity change were 200 times larger than steady-state water flux. The analysis completely reconciles data from osmotic transient, tracer dilution, and lymph sampling techniques.
引用
收藏
页码:H1317 / H1331
页数:15
相关论文
共 59 条
  • [1] ADAMSON RH, 1990, J PHYSIOL-LONDON, V428, P1
  • [2] ADAMSON RH, 1993, J PHYSIOL-LONDON, V466, P303
  • [3] HEART CAPILLARY PERMEABILITY TO LIPID-INSOLUBLE MOLECULES
    ALVAREZ, OA
    YUDILEVICH, DL
    [J]. JOURNAL OF PHYSIOLOGY-LONDON, 1969, 202 (01): : 45 - +
  • [4] PLASMA-PROTEIN CONCENTRATION AND CONTROL OF CORONARY VASCULAR-RESISTANCE IN ISOLATED RAT-HEART
    AVOLIO, AP
    SPAAN, JAE
    LAIRD, JD
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1980, 238 (04): : H471 - H480
  • [5] MICROVASCULATURE OF DOG LEFT-VENTRICULAR MYOCARDIUM
    BASSINGT.JB
    YIPINTSO.T
    HARVEY, RB
    [J]. MICROVASCULAR RESEARCH, 1974, 7 (02) : 229 - 249
  • [6] A COMPARISON OF ASCORBATE AND GLUCOSE-TRANSPORT IN THE HEART
    BASSINGTHWAIGHTE, JB
    KUIKKA, JT
    CHAN, IS
    ARTS, T
    RENEMAN, RS
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1985, 249 (01): : H141 - H149
  • [7] A MODEL FOR OSMOTICALLY INDUCED WEIGHT TRANSIENT IN THE ISOLATED RABBIT HEART
    BLOOM, G
    JOHNSON, JA
    [J]. MICROVASCULAR RESEARCH, 1981, 22 (01) : 64 - 79
  • [8] Bosan S, 1996, ANN BIOMED ENG, V24, P124, DOI 10.1007/BF02771001
  • [9] THE 3-DIMENSIONAL ORGANIZATION OF TIGHT JUNCTIONS IN A CAPILLARY ENDOTHELIUM REVEALED BY SERIAL-SECTION ELECTRON-MICROSCOPY
    BUNDGAARD, M
    [J]. JOURNAL OF ULTRASTRUCTURE RESEARCH, 1984, 88 (01): : 1 - 17
  • [10] Caldwell JH, 1998, J NUCL MED, V39, P1327